Question

Question 1 You are assigned to carry out a preliminary design for a water treatment process....

Question 1

You are assigned to carry out a preliminary design for a water treatment process. A pollutant of concern, denoted ‘A’, is known to degrade in water. But you do not know the rate law or reaction rate constant. You conduct a series of experiments. In each case, you established an initial concentration of 50 mg/L of pollutant ‘A’ in water in a sealed vessel. After a certain period, you open the vessel and measure the remaining concentration of ‘A’. The results of your experiment are tabulated below:

Experiment                  Duration of Experiment                                    Final Concentration (mg/L)

           

1                                  1 hour                                                  35

2                                  3 hours                                                 17

3                                  6 hours                                                 6

a) What is the rate constant?

b) You are to design a reactor to treat a constant flow rate of 0.3 m3/s of water containing 50 mg/L of ‘A’. If the reactor is configured as a complete mixed flow system, how large must it be to achieve 90% removal of ‘A’.

c) Size a plug-flow reactor in place of complete mixed flow reactor for the similar situation mentioned in (b).

d) If you would like to propose two complete mix reactors of equal volume in series what should be the volume of each reactor.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 1.0 � 106 gallon reactor is used in a sewage-treatment plant. The influent biochemical oxygen...
A 1.0 � 106 gallon reactor is used in a sewage-treatment plant. The influent biochemical oxygen demand (BOD) concentration is 100 mg/L, the effluent BOD concentration is 25 mg/L, and the flow rate through the reactor is 500 gal/min. (a) What is the first-order rate constant for decay of BOD in the reactor? Assume that the reactor can be modeled as a comply mixed flow reactor (CMFR). Report your answer in units of per hour. (b) Assume that the reactor...
What is the effluent concentration of a reactive contaminant exiting a completely mixed flow reactor after...
What is the effluent concentration of a reactive contaminant exiting a completely mixed flow reactor after 8 hours of operation? Assume that after this length of time, the reactor is at steady state. The volume of the reactor is 100 L and the volumetric flow rate is 50 L/hr. The influent concentration of the contaminant is 80 mg/L and the rate constant for the decay of the contaminant is 0.5 hr-1.
An activated sludge system has three square reactor tanks in series (CFSTRs) that are each 60...
An activated sludge system has three square reactor tanks in series (CFSTRs) that are each 60 ft wide, 60 ft long, and 18 ft deep. The engineers have decided to add a new reactor in parallel. It will be a plug flow reactor (PFR) with a depth of 18 feet and a width of 18 feet. The length is to be calculated. The flowrate of wastewater is 2 MGD and the BOD is 165 mg/L. This will be split in...
A mine produces a wastewater discharge of 701 m^3/d containing 11,945 mg/L of total dissolved solids...
A mine produces a wastewater discharge of 701 m^3/d containing 11,945 mg/L of total dissolved solids (TDS). This discharge is released into a freshwater stream with a flow of 16,867 m^3/d containing 222 mg/L TDS. The water discharge permit states that the water downstream from the discharge must not exceed a TDS concentration of 399 mg/L. The mine plans to use an ion exchange reactor to regulate the TDS. This technology removes TDS while allowing clean water to pass through,...
The conversion of ferrous ions to ferric ions by dissolved oxygen in the presence of bacteria...
The conversion of ferrous ions to ferric ions by dissolved oxygen in the presence of bacteria is a first order reaction with respect to ferrous ions in the concentration range of 0.1 – 0.6 mol L-1 . The rate of oxidation of 0.6 mol L-1 ferrous ions is 0.25 mol L-1 min-1 . Calculate the following: (a) First order rate constant for the oxidation reaction. (b) Time taken for 70% conversion of ferrous ions at an initial concentration of 0.6...
Design a completely mixed activated sludge process using three different design approaches (i.e. calculate the volume...
Design a completely mixed activated sludge process using three different design approaches (i.e. calculate the volume of the aeration basin). Base your design for the first approach on detention time, for the second one on BOD loading, and the third one on kinetics. The influent design flow rate to the activated sludge process is 10,000 m3 /day with a BOD5 concentration of 200mg/L. Completely mixed activated sludge processes typically have a detention time ranging from 3 to 6 hours and...
Suppose you are to design a chlorination tank for killing microorganisms in the effluent from a...
Suppose you are to design a chlorination tank for killing microorganisms in the effluent from a wastewater treatment plant. It is necessary to achieve 99.99% kill in a wastewater flow of 100 m3/hr. Assume the disinfection is a first-order reaction with a rate constant of 0.2 min−1. A) First, calculate the tank volume if the contact tank is a CMF reactor. B) Then, calculate the tank volume if the contact tank is a plug-flow reactor. C) Last, what is the...
A clean lake with a constant volume of 107 m3 is fed by a pollution-free stream...
A clean lake with a constant volume of 107 m3 is fed by a pollution-free stream with flow rate of 50 m3/s. A factory dumps 5.0 m3/s of waste with a pollutant concentration of 100 mg/L into the lake. The pollutant has a first-order reaction rate coefficient (decay) of 0.25 d-1. Assuming the pollutant is well-mixed in the lake. How long does it take the lake to reach the steady-state concentration? You may assume that if concentration is approximately 99%...
The town of Camp Verde has been directed to upgrade its primary Waste Water Treatment Plant...
The town of Camp Verde has been directed to upgrade its primary Waste Water Treatment Plant (WWTP) to a secondary plant that can meet an effluent standard of 25 mg/L BOD5 and 30 mg/L suspended solids. They have selected a completely mixed activated sludge system for the upgrade. The existing primary treatment plant has a flow rate of 0.029 m3/s. The effluent from the primary tank has a BOD5 of 240 mg/L. Using the following assumptions, estimate the required volume...
environmental engineering wastewater treatment. waste water treatment. 1- In a 2 steps cascade aeration, each step...
environmental engineering wastewater treatment. waste water treatment. 1- In a 2 steps cascade aeration, each step increases oxygen concentration from 10 % to 30 % of saturation level. If the initial oxygen concentration is 20 % of saturation level and minimum oxygen is required to be 5 mg/L at the end of aeration, is the system efficient or not? Show your calculations. Inlet water temperature is 15 C (Cs = 10.2 mg/L) 2- Design flocculation tanks (2 tanks, 5 compartments...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT