Question

Difference between boiler and heater

Difference between boiler and heater

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
An iron boiler of mass 180 kg contains 790 kgof water at 21 ∘C. A heater...
An iron boiler of mass 180 kg contains 790 kgof water at 21 ∘C. A heater supplies energy at the rate of 58,000 kJ/h. The specific heat of iron is 450 J/kg⋅C∘, the specific heat of water is 4186 J/kg⋅C∘, the heat of vaporization of water is 2260 kJ/kg⋅C∘. Assume that before the water reaches the boiling point, all the heat energy goes into raising the temperature of the iron or the steam, and none goes to the vaporization of...
A steam power plant design details are supplied as follows. The boiler tubes can withstand pressures...
A steam power plant design details are supplied as follows. The boiler tubes can withstand pressures 6.3 MPa and to a maximum temperature of 460 0C. The condenser operates at 66 0C. The pumps and turbines available can handle only single-phase materials, and they operate isentropically. Is there a need for any reheat for this cycle? If so, how many stages of reheat are needed? What is the maximum temperature at the exit of the last heater? What is the...
1. A 120 V potential difference is applied to a space heater whose resistance is 19.8...
1. A 120 V potential difference is applied to a space heater whose resistance is 19.8 Ω when hot. At what rate is electrical energy being transferred to thermal energy? 2. How much thermal energy is produced in 4.2 hours? 3. If electricity costs 10.0 cents per kW·h, how much does it cost to operate the device for 4.2 hours?
An electrical water boiler is used for supplying steam to the process in the food industry....
An electrical water boiler is used for supplying steam to the process in the food industry. The rating of the boiler is 30kW. It is proposed to replace this boiler with a new energy efficient boiler. The new boiler costs $125,000. The new boiler can save 30% energy at 60% loading when compared with the old boiler. The erection and commissioning cost of the new boiler is $20,000. The resale value of the old boiler is $10,000. The maintenance contract...
A boiler with a volume of 2 cubic meters contains water with half liquid and half...
A boiler with a volume of 2 cubic meters contains water with half liquid and half steam at a temperature of 200 degrees. The valve located under the boiler is opened and liquid output is provided and during this time, heat is input to the boiler from a 300 degree heat source to keep the temperature inside the boiler constant. When half of the water body in the boiler is drawn;    a) Find the first and the last degree...
A paper was reporting on the lifetime of a certain type of boiler. The average lifetime,...
A paper was reporting on the lifetime of a certain type of boiler. The average lifetime, based on 25 samples, was reported as 12 years. The paper also reported a p-value of 0.0088 to support the claim that this boiler’s average lifetime is less than 15 years. He, however, neglected to report the standard deviation of the boiler lifetime.a. What is the standard deviation of the boiler lifetime?b. Find a 95% confidence interval for the boiler lifetime?
A steam Rankine cycle operates between the pressure limits of 1500 psia in the boiler and...
A steam Rankine cycle operates between the pressure limits of 1500 psia in the boiler and 6 psia in the condenser. The turbine inlet temperature is 800°F. The turbine isentropic efficiency is 90 percent, the pump losses are negligible, and the cycle is sized to produce 2500 kW of power. How much error is caused in the thermal efficiency if the power required by the pump were completely neglected? Use steam tables. The error caused in the thermal efficiency if...
Suggest a suitable pressure at which dry saturated steam should be supplied to a calorifier (heater)...
Suggest a suitable pressure at which dry saturated steam should be supplied to a calorifier (heater) to maintain a chemical process at 140°C, and calculate how much steam would be condensed to provide heat at the rate of 7000 MJ h–1. Allow a temperature difference of 25°C between the steam and the process fluid for effective heat transfer.
1. Find the current in an 8-ohm electric heater operated at 120-V. 2. Distinguish between electric...
1. Find the current in an 8-ohm electric heater operated at 120-V. 2. Distinguish between electric potential energy and voltage. What are two things that are required for there to be a current in a circuit?
Boiler monitor: we will create an app using JavaScript and JQUARY that monitors the temperature and...
Boiler monitor: we will create an app using JavaScript and JQUARY that monitors the temperature and pressure of a boiler. You can model the app based on the Thyroid app. In this chapter, we will create the skeleton of the app, similar to the Thyroid app. Now, just create the pages and the links to navigate between them; you will implement the functionality of the pages in later chapters. The app will have A password-based entry page. A page to...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT