Question

Liquid water is pumped at 94 ° C from a storage tank at a rate of...

Liquid water is pumped at 94 ° C from a storage tank at a rate of 50 gal / min by means of a pump with a 2 HP motor and an efficiency of 80%. The water passes through a condenser delivering heat at a rate of 40,000 kJ / min, and is then deposited in a second storage tank that is 15 m above the first tank. Estimate the temperature of the water deposited in the second tank.

Homework Answers

Answer #1

I hope you can understand the solution.

Thank you!!!

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Hot water in an open storage tank at 82.2°C is being pumped at a rate of...
Hot water in an open storage tank at 82.2°C is being pumped at a rate of 0.379 m3/min from the tank. The line from the storage tank to the pump suction is 6.1 m of 2-in schedule 40 steel pipe and it contains two elbows. The water discharge line after the pump is 61 m of 2-in pipe and contains two elbows. The water discharges to the atmosphere at a height of 6.1 m above the water level in the...
Water is pumped by a motor-pump unit from a lake to a storage tank 17 m...
Water is pumped by a motor-pump unit from a lake to a storage tank 17 m above at a rate of 120 L/s. The storage tank is open to the atmosphere. The motor consumes 25 kW of electric power and the motor effciency is 95%. Disregarding any changes in kinetic energy of the water, determine (a) the overall effciency of the pump-motor unit, (b) the effciency of the pump and (c) the shaft power supplied by the motor to the...
Water is pumped from a storage tank into a tube of 3.00 cm diameter (inner) at...
Water is pumped from a storage tank into a tube of 3.00 cm diameter (inner) at a rate of 0.001m3/s. What is the specific kinetic energy of the water? (Include all units and conversions)
A farmer wants to pump water from a river to a very big open storage tank...
A farmer wants to pump water from a river to a very big open storage tank nearby using a 55-m long, 16-cm diameter plastic pipe with 5 threaded 90° regular bends, 5 threaded 45° regular bends, and one fully open gate valve. The water velocity near the river surface is 2.7 m/s and the pipe's inlet is placed in the river normal to the direction of water flow to take advantage of this water speed. The elevation difference between the...
A pumping system is designed to pump from a storage reservoir located at an elevation of...
A pumping system is designed to pump from a storage reservoir located at an elevation of 1015 feet. The pump elevation is 1005 feet. The pump discharge flow rate is 4500 gal/min and the water temperature is 100˚ F. Between the storage tank and the pump is 30 feet of 14-in DIP pipe (f = 0.018) with one (1) rounded entrance (kent = 0.05), and two (2) 45 -degree bends (k45 = 0.30). What is the NPSHA for this system?...
Water at 20 0C is pumped at a rate of Q4= 0.042 m3/s from lower reservoir...
Water at 20 0C is pumped at a rate of Q4= 0.042 m3/s from lower reservoir to a higher reservoir with a height difference of H4=37 m as shown in the figure. The flow is assumed steady and incompressible. If irreversible losses in the pipe can be neglected, calculate the pump efficiency in percent, if the electric motor is rated at P4=29.1 kW and the motor efficiency can be assumed to be n4=87%. Answer:
Water at 20 0C is pumped at a rate of Q4= 0.022 m3/s from lower reservoir...
Water at 20 0C is pumped at a rate of Q4= 0.022 m3/s from lower reservoir to a higher reservoir with a height difference of H4=43 m as shown in the figure. The flow is assumed steady and incompressible. If irreversible losses in the pipe can be neglected, calculate the pump efficiency in percent, if the electric motor is rated at P4=29.4 kW and the motor efficiency can be assumed to be n4=82%.
Water is being pumped at 20°C From an open tank through a 0.03561 m smooth pipe...
Water is being pumped at 20°C From an open tank through a 0.03561 m smooth pipe to a second tank at a higher level. The flow rate is 0.8 kg/s through 40 m of straight pipe with two threaded 90 regular elbows, one fully open globe valve and one half open gate valve. The supply tank maintains a liquid level of 2 m, and the water leaves the system at an elevation of 10 m above the floor. Calculate Reynolds...
A geothermal heat pump is used in winter for space heating by getting heat from the...
A geothermal heat pump is used in winter for space heating by getting heat from the ground at 15 °C. The working fluid in the heat pump is R134a. The compressor inlet is at 400 kPa and the compressor exit is at 2 MPa and 60 C. The mass flow rate of the refrigerant is 0.1 kg / s and the temperature difference in the air flow in the condenser section is 12 C. The refrigerant is subcooled to 15...
City water will be cooled in a heat exchanger by sea water entering at 15°C. The...
City water will be cooled in a heat exchanger by sea water entering at 15°C. The outlet temperature of the sea water is 20°C. City water will be recirculated to reduce water consumption. The suction line of the pump has an inner diameter of 154 mm, is 22 m long, and has two 90° bends and a hinged check valve. The pipe from the pump to the heat exchanger has an inner diameter of 127 mm, is 140 m long,...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT