The fluid in a heat exchanger in a process plant needs to be warmed up prior...

The fluid in a heat exchanger in a process plant needs to be warmed up prior to having process startup. The shell side of the heat exchanger contains the process fluid (water) while the tube side is supplied with steam at 150°C to facilitate the heating. Assume the exterior is well insulated such that heat losses are negligible.

a) Derive the ODE and analytically solve for the function that describes the temperature of the fluid in the heat exchanger with respect to time.

b) If the overall heat transfer coefficient is 250 W/m2K, the area of the heat exchanger is 650 m2, the volume of water is 12.5 m3, the density and cp of the water are 990 kg/m3 and 4200 J/kg K respectively, how long would it take to have the water at 140°C?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A process fluid having a specific heat of 3500 J/kg?K and flowing at 2 kg/s is...
A process fluid having a specific heat of 3500 J/kg?K and flowing at 2 kg/s is to be cooled from 80 °C to 40 °C with chilled water, which is supplied at a temperature of 15 °C and a flow rate of 2.5 kg/s. Assuming an overall heat transfer coefficient of 2000 W/m2?K, calculate the required heat transfer areas for the following exchanger configurations: (a) Parallel flow; (b) Counter flow; (c) a 1-2 shell and tube exchanger with the water...
The condenser of a large steam power plant is a heat exchanger in which steam is...
The condenser of a large steam power plant is a heat exchanger in which steam is condensed to liquid water. Assume the condenser to be a parallel flow shell-and-tube heat exchanger consisting of a single shell and 10,000 tubes, each executing two passes. The tubes are of thin wall construction with D = 30 mm and the steam condenses on their outer surface. The heat transfer rate that must be effected by the exchanger is Q = 2 × 10^9...
The properties of the fluid are: density 895 kg/m3, viscosity 0.76 mNm-2s. A double-pipe heat exchanger...
The properties of the fluid are: density 895 kg/m3, viscosity 0.76 mNm-2s. A double-pipe heat exchanger is to be used to heat 6000 kg/h of 22 mol per cent hydrochloric acid. The exchanger will be constructed from karbate (impervious carbon) and steel tubing. The acid will flow through the inner, karbate, tube and saturated steam at 100ºC will be used for heating. The tube dimensions will be: karbate tube inside diameter 50 mm, outside diameter 60 mm; steel tube inside...
Saturated water vapor leaves a steam turbine at a flow rate of 1.47 kg/s and a...
Saturated water vapor leaves a steam turbine at a flow rate of 1.47 kg/s and a pressure of 0.51 bar. The vapor is to be completely condensed to saturated liquid in a shell-and-tube heat exchanger that uses city water as the cold fluid. The water enters the thin-walled tubes at 17oC and is to leave at 57.6 oC. Assuming an overall heat transfer coefficient of 2000 W/m2K, determine the required heat exchanger surface area and the water flow rate. cp,c...
A shell and-tube heat exchanger is required for the following service: Hot stream Cold Stream Aromatic...
A shell and-tube heat exchanger is required for the following service: Hot stream Cold Stream Aromatic Stream Cooling Water inlet Temperature (oC) 85 20 outlet Temperature (oC) 40 35 Mass Flowrate x heat Capacity (kW/oC) 85.2 Hot Stream cold stream (Cooling water) Heat Capacity (J/kg K) 2840 4193 Density (kg/m3) 750 999 Viscosity (cP) 0.34 1.016 Thermal conductivity (W/m.K) 0.19 0.594 Fouling Factor (m2.oC/W 0.00018 0.000176 ? The cooling water is allocated to the tube-side of the exchanger. ? It...
Two products enter an indirect contact heat exchanger that uses steam for heating. The first product...
Two products enter an indirect contact heat exchanger that uses steam for heating. The first product which contains 15% solids enters at the rate of 3 kg/hr and at 10 °C. The second stream which contains 20% solids enters at the rate of 4 kg/hr and at 20 °C. Saturated steam at 140 °C enters the heat exchanger at 0.5 kg/hr with a quality of 95% and exits at 10% quality at 140 °C. The resulting mixture enters an indirect...
Question 2. Answer all parts of this question a) A shell and tube heat exchanger is...
Question 2. Answer all parts of this question a) A shell and tube heat exchanger is to heat 10,000 kg h–1 of water from 16 to 84°C using hot oil entering at 160°C and leaving at 92°C. The oil will flow through the shell of the heat exchanger. The water will flow through 11 brass tubes of 22.9 mm inside diameter and 25.4 mm outside diameter, with thermal conductivity 137 W m–1 K–1, with each tube making two passes through...
A concentric tube heat exchanger is comprised of a stainless steel (ks = 40 W/mK) inner...
A concentric tube heat exchanger is comprised of a stainless steel (ks = 40 W/mK) inner pipe, NPS 2- nominal schedule 40 size (corresponding to an inner diameter of 52.5 mm and an outer diameter of 60.3 mm), and an outer stainless steel pipe of NPS 3-nominal schedule 40 (ID = 77.9 mm, OD = 88.9 mm). The heat exchanger has an effective length of 35 m. The inner pipe fluid is ammonia (?a = 0.3 · 10?6 m2/s, cpa...
A concentric tube heat exchanger is comprised of a stainless steel (ks = 40 W/mK) inner...
A concentric tube heat exchanger is comprised of a stainless steel (ks = 40 W/mK) inner pipe, NPS 2- nominal schedule 40 size (corresponding to an inner diameter of 52.5 mm and an outer diameter of 60.3 mm), and an outer stainless steel pipe of NPS 3-nominal schedule 40 (ID = 77.9 mm, OD = 88.9 mm). The heat exchanger has an effective length of 35 m. The inner pipe fluid is ammonia (va = 0.3 · 10-6m2/s, cpa =...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT