Question

A venturi meter is used to measure the flow rate of water at 26.7°C in a...

A venturi meter is used to measure the flow rate of water at 26.7°C in a pipe. The venturi meter having a throat diameter of 38 mm and its coefficient is 0.98. When the water flow rate in the pipe is 72 m'h, the manometer reading is 1.253 m of mercury. The density of mercury is 13600 kg/m'. Calculate the inside diameter of the pipe in mm

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
1.2 A horizontal Venturi meter is used to measure the flow of water in a 400mm...
1.2 A horizontal Venturi meter is used to measure the flow of water in a 400mm diameter pipe. The throat diameter of the Venturi meter is 100mm and the the discharge coefficient is 0.85. if the pressure difference between the two measurement points is 10cm of mercury, then calculate the average velocity in the pipe. take the relative density of mercury as 13.6. b) What diameter pipe would be required to double the capacity for the 400mm concrete conduit pipe...
A venturimeter is used to measure water flow rate of 7.5m^3/min. If pressure difference between the...
A venturimeter is used to measure water flow rate of 7.5m^3/min. If pressure difference between the wide and throat sections of the venturi is 12.50 kPa, and the pipe diameter at the wide section is 20 cm, calculate the throat diameter. (Use density=1000 kg/m^3 and coefficient of discharge Cd=0.96).
A venturimeter of 150 mm × 75 mm size is used to measure the flow rate...
A venturimeter of 150 mm × 75 mm size is used to measure the flow rate of oil having specific gravity of 0.9. The reading shown by the U tube manometer connected to the venturimeter is 150 mm of mercury column. Calculate the coefficient of discharge for the venturimeter if the flow rate is 1.7 m3/min. (Note: The size of venturimeter generally specified in terms of inlet and throat diameters)
A pump delivers water (r= 1000 kg/m3, µ= 0.860x10-3 kg/m·s) from one reservoir to another reservoir...
A pump delivers water (r= 1000 kg/m3, µ= 0.860x10-3 kg/m·s) from one reservoir to another reservoir through 120 m of 0.05 m diameter pipe. Volumetric flow rate in the pipe line is measured with venturi meter. Throat diameter of venturi meter is 38 mm and pressure drop in the venturi meter is 156.9 kPa.The surface of the pipe is rough e/D=0.0001. Calculate the power of the pump required for the water–transfer. See the figure below for several pipe– fittings installed...
I'm needing assistance calculating the flow rate of a venturi Pipe diameter upstream of venturi, Da-...
I'm needing assistance calculating the flow rate of a venturi Pipe diameter upstream of venturi, Da- 10in Diameter of venturi neck, Db: 7 in Pressure difference measured by venturi, Dp: 10 Pa Fluid density, r: 1.29lb/in^3 Discharge Coefficient, C: 0.98. [Please show me how these calculations were reached]
An orifice and a mercury manometer are used to accurately determine the flow of water through...
An orifice and a mercury manometer are used to accurately determine the flow of water through a 200mm diameter pipe. The volumetric flow rate through the pipe is 0.9m^3/s. Determine the diameter of the orifice that will cause a reading of 150mm between the mercury levels. Take Cd = 0.67
A Venturi tube may be used as a fluid flow meter. If the fluid flow rate...
A Venturi tube may be used as a fluid flow meter. If the fluid flow rate in m3/s is 2.2 * 10-3 and the radius R1 = 2.4 *10-2 m of the inlet tube is 2.1 times the radius R2 of the outlet tube, and the fluid is water (ρ = 1000 kg/m3). Find the pressure difference P1 - P2 in units of kPa.
A venturi meter is a device for measuring the speed of a fluid within a pipe....
A venturi meter is a device for measuring the speed of a fluid within a pipe. The drawing shows a gas flowing at a speed v2 through a horizontal section of pipe whose cross-sectional area A2 = 0.0800 m2. The gas has a density of ρ = 1.70 kg/m3. The Venturi meter has a cross-sectional area of A1 = 0.0500 m2 and has been substituted for a section of the larger pipe. The pressure difference between the sections is P2...
A venturi meter is a device for measuring the speed of a fluid within a pipe....
A venturi meter is a device for measuring the speed of a fluid within a pipe. The drawing shows a gas flowing at a speed v2 through a horizontal section of pipe whose cross-sectional area A2 = 0.0600 m2. The gas has a density of ϝ = 1.40 kg/m3. The Venturi meter has a cross-sectional area of A1 = 0.0400 m2 and has been substituted for a section of the larger pipe. The pressure difference between the two sections is...
An orifice plate flow sensor is used to measure the flow of water in a 2-in....
An orifice plate flow sensor is used to measure the flow of water in a 2-in. ID pipe. The orifice plate has a 1.5-in. diameter hole. The pressure difference across the plate is 0.3 psi. Find the approximate water flow in the pipe.
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT