Question

Cold water leading to a shower enters a well-insulated, thin-walled, double-pipe, counterflow heat exchanger at 10C...

Cold water leading to a shower enters a well-insulated, thin-walled, double-pipe, counterflow heat exchanger at 10C at a rate of 1.15kg/s and is heated to 70C by hot water that enters at 85C at a rate of 1.6kg/s. Use data from the tables to Determine the rate of entropy generation in the heat exchanger. Answer in kW/K.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A thin-walled double pipe counter flow heat exchanger is to be used to cool oil (cp...
A thin-walled double pipe counter flow heat exchanger is to be used to cool oil (cp = 2200 j/kg*K) from 150 ℃ to 30 ℃ at a rate of 2.1 kg/s by water (cp= 4180 J/kg*K) that enters at 20 ℃ at a rate of 1.2 kg/s. The diameter of the tube is 2.5 cm, and its length is 10 m. Using Excel (a) Determine the overall heat transfer coefficient of this heat exchanger. (b) Investigate the effects of oil...
Cold water enters a counter flow heat exchanger at 20ºC at a rate of 10 kg/s,...
Cold water enters a counter flow heat exchanger at 20ºC at a rate of 10 kg/s, where it is heated by a hot water stream that enters the heat exchanger at 80ºC at a rate of 2 kg/s. Assuming the specific heat of water to remain constant at Cp=4.18 kJ/(kg.ºC), determine the maximum heat transfer rate and the outlet temperatures of the cold and the hot water streams.
Hot water enters a counter-flow double-pipe heat exchanger at 180F with a velocity of 5 ft/s....
Hot water enters a counter-flow double-pipe heat exchanger at 180F with a velocity of 5 ft/s. Cold water at 80F flows at 3 ft/s in the outer section of the exchanger. The diameter of the inner pipe is 1 inch, the pipe wall thickness is 1/8", and the outer pipe diameter is 2 inches. The overall heat transfer coefficient times area per unit length UA/L = 150 Btu/hr-ft-F. If the exchanger is 16 feet long, what is the exit temperature...
A counter current double pipe heat exchanger is used to boil but not superheat water at...
A counter current double pipe heat exchanger is used to boil but not superheat water at 100 DegreeC at rate of about 0.1 kg/s. This is achieved by flowing hot oil at 400 DegreeC through the inner pipe at a rate of 5 kg/s. Latent heat of water: 2265 kJ/kg Heat capacity of water: 4180 J/kgK Heat capacity of the oil: 1800 J/kgK What is the temperature of he hot oil leaving the heat exchanger? What is the overall heat...
Water is heated in a mixing chamber by mixing it with hot water coming from a...
Water is heated in a mixing chamber by mixing it with hot water coming from a heater. The mixing chamber loses heat to the surroundings at a rate of 5 kW. The hot water enters the mixing chamber at a rate of 1 kg/s. The mixed water leaves the chamber fully mixed. - The cold water enters the mixing chamber at 200 kPa and 20°C at a velocity of 3 m/s - The hot water enters at a pressure of...
Problem 8.24 Water is used to cool ethylene glycol in a 60-ft-long double pipe heat exchanger...
Problem 8.24 Water is used to cool ethylene glycol in a 60-ft-long double pipe heat exchanger made of 4-std and 2-std (both type M) copper tubing. The water inlet temperature is 60°F and the ethylene glycol inlet temperature is 180°F. The flow rate of the ethylene glycol is 20 lbm/s, while that for the water is 30 lbm/s. Calculate the expected outlet temperature of the ethylene glycol and determine the pressure drop expected for both streams. Assume counterflow, and place...