Question

Water (25 oC) is in an open tank at atmospheric pressure and the pump is 4.9...

Water (25 oC) is in an open tank at atmospheric pressure and the pump is 4.9 m below the open level. The friction head loss in the pipe is 1.5 m. Draw a diagram and calculate the Net Positive Suction Head.

Homework Answers

Answer #1

NPSH help so to find out at which suction head pump can be installed.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Hot water in an open storage tank at 82.2°C is being pumped at a rate of...
Hot water in an open storage tank at 82.2°C is being pumped at a rate of 0.379 m3/min from the tank. The line from the storage tank to the pump suction is 6.1 m of 2-in schedule 40 steel pipe and it contains two elbows. The water discharge line after the pump is 61 m of 2-in pipe and contains two elbows. The water discharges to the atmosphere at a height of 6.1 m above the water level in the...
A farmer wants to pump water from a river to a very big open storage tank...
A farmer wants to pump water from a river to a very big open storage tank nearby using a 55-m long, 16-cm diameter plastic pipe with 5 threaded 90° regular bends, 5 threaded 45° regular bends, and one fully open gate valve. The water velocity near the river surface is 2.7 m/s and the pipe's inlet is placed in the river normal to the direction of water flow to take advantage of this water speed. The elevation difference between the...
The NPSHR for a pump is given by the pump manufacturer as 7.2 m. This pump...
The NPSHR for a pump is given by the pump manufacturer as 7.2 m. This pump is being used to pump water from a reservoir at a rate of 300 L/sec. Water temperature is 15 0C and 300C in winter and summer, respectively. Assume total head loss in the suction pipe is 1.5 m. Determine whether or not the pump is safe from cavitation in a) winter b) summer
A single acting reciprocating pump has a piston of 200mm diameter and a stroke of 320...
A single acting reciprocating pump has a piston of 200mm diameter and a stroke of 320 mm and runs at 15 rpm. The level of the water in the sump is 5m below the center line of the pump and the storage reservoir is 25m above the center line of the pump. The suction and delivery pipes are 10m and 26m long and are 100mm and 125mm in diameter respectively. Assume vapor pressure of water as 2.1m (absolute), friction factor...
A centrifugal pump with a 10 cm suction pipe and a 7.5 cm diameter discharge pipe...
A centrifugal pump with a 10 cm suction pipe and a 7.5 cm diameter discharge pipe has a measured capacity of 0.019 m3/s (water), a suction side vacuum of 20 cm mercury (relative density = 13.6) and a discharge pressure of 240345 N/m2 (gage).  The suction and discharge pipes are at the same elevation.  Assuming that the head loss due to friction is negligible, what is the pump power required
A pump is filling a cylindrical water tank 25 feet in diameter and 25 feet high....
A pump is filling a cylindrical water tank 25 feet in diameter and 25 feet high. The pump flow rate is 300 GPM, after 2 hours of operation, the pressure exerted from the water on the bottom of the tank is _____ psi. (Assume that the tank was empty prior to the pumping process)
A 3-m-diameter tank is initially filled with water 2 m above the center of a sharp-edged...
A 3-m-diameter tank is initially filled with water 2 m above the center of a sharp-edged 10-cmdiameter orifice. The tank water surface is open to the atmosphere, and the orifice drains to the atmosphere through a 100-m-long pipe. The friction coefficient of the pipe can be taken to be 0.015 and the effect of the kinetic energy correction factor can be neglected. Someone suggests that it makes no difference whether the pump is located at the beginning or at the...
A pump is used to carry water (T =60 oF and ν = 1.217×10-5 ft2/s) from...
A pump is used to carry water (T =60 oF and ν = 1.217×10-5 ft2/s) from a large tank (elevation of surface = 30 ft and at atmospheric pressure) through a pipe to the exit (elevation 60 ft) at a rate Q = 1.5 cfs as shown below. The pipe is made of cast iron (ε = 0.00085 ft). The pipe segment before the pump has length L = 500 ft (three horizontal sections of 160 ft each and two...
An 80% efficient pump draws 68.5 gallons per minute of water from an aquifer through a...
An 80% efficient pump draws 68.5 gallons per minute of water from an aquifer through a 4-inch ID pipe and discharges it through a 2-inch ID pipe to a tank, which is 100 ft above the water level in the aquifer. The friction loss in the pipe is 15 ft.lbf/lbm. What is the required pump horsepower?
(d) A centrifugal pump delivers 1000 Ls-1 of water at a head of 3 m and...
(d) A centrifugal pump delivers 1000 Ls-1 of water at a head of 3 m and speed of 60 rpm. Determine the Net Positive Suction Head Required. Answer is [NPSHR = 0.196 m] How do i do this?
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question