Question

The purchased cost of a 5-m3 stainless steel tank in 1995 was $10,900. The 2-m-diameter tank...

The purchased cost of a 5-m3 stainless steel tank in 1995 was $10,900. The 2-m-diameter tank is cylindrical with a flat top and bottom. If the entire outer surface of the tank is to be covered with 0.05-m-thickness of magnesia block, estimate the current total cost for the installed and insulated tank. The 1995 cost for the 0.05-m-thick magnesia block was $40 per square meter while the labor for installing the insulation was $95 per square meter.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
The purchased cost of 1500 gal stainless steel tank in 1980 was $7000. The tank is...
The purchased cost of 1500 gal stainless steel tank in 1980 was $7000. The tank is spherical and the diameter of it is 6 ft. If the entire outer surface of the spherical tank is to be covered with 2 in. thickness of magnesia block, estimate the present total cost for the installed and insulated tank. The Jan. 1,1980 cost for 2 in. magnesia block was $2.20 per ft2 while the labor for installing the insulation was $5.00 per ft2.
A steel pipe has an outer diameter of 0.06 m. It is covered with a 0.05...
A steel pipe has an outer diameter of 0.06 m. It is covered with a 0.05 m thick layer of magnesia (k = 0.07 W m-1 K -1) which in turn is covered with a 0.04 m layer of fibreglass insulation (k = 0.048 W m-1 K -1). The pipe wall outside temperature is 380 K, and the outside surface temperature of the fibreglass is 310 K. What is the interfacial temperature between the magnesia and the fibreglass? [Q/L =...
A steel hot-water tank of cylindrical shape has an inside diameter of 0.600 m and inside...
A steel hot-water tank of cylindrical shape has an inside diameter of 0.600 m and inside height of 1.40 m. The tank is enclosed by a 5.00 cm thick insulating layer of glass wool whose thermal conductivity is 0.0350 W / (m·K). The insulation is covered by a thin sheet metal skin. The steel tank and the sheet metal skin have thermal conductivities that are much greater than that of the glass wool. How much electrical power (W) must be...
A 3-m-internal-diameter spherical tank made of 1-cm-thick stainless steel is used to store iced water at...
A 3-m-internal-diameter spherical tank made of 1-cm-thick stainless steel is used to store iced water at 0°C. The tank is located outdoors at 18°C. Assume the entire steel tank to be at 0°C and thus the thermal resistance of the tank to be negligible. The heat of fusion of water at atmospheric pressure is hif = 333.7 kJ/kg. The emissivity of the outer surface of the tank is 0.75, and the convection heat transfer coefficient on the outer surface can...
2.1Consider a solid cylindrical rod of length 0.15 m and diameter 0.05 m. The top and...
2.1Consider a solid cylindrical rod of length 0.15 m and diameter 0.05 m. The top and bottom surfaces of the rod are maintained at constant temperatures of 20oC and 95oC, respectively, while the side surface is perfectly insulated. 2.1.1 Draw a diagram to represent the situation described above. (3) 2.1.2 Determine the rate of heat transfer through the rod if it is made of copper, k = 380 W/m? oC. (4) 2.1.3 Determine the rate of heat transfer through the...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT