Write down the total heat transfer resistance for a double-pipe heat exchanger. Show how to convert...

Write down the total heat transfer resistance for a double-pipe heat exchanger. Show how to convert from the total resistance to an overall heat-transfer co-efficient and explain how flow regime may affect overall heat transfer rate.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A thin-walled double pipe counter flow heat exchanger is to be used to cool oil (cp...
A thin-walled double pipe counter flow heat exchanger is to be used to cool oil (cp = 2200 j/kg*K) from 150 ℃ to 30 ℃ at a rate of 2.1 kg/s by water (cp= 4180 J/kg*K) that enters at 20 ℃ at a rate of 1.2 kg/s. The diameter of the tube is 2.5 cm, and its length is 10 m. Using Excel (a) Determine the overall heat transfer coefficient of this heat exchanger. (b) Investigate the effects of oil...
A counter current double pipe heat exchanger is used to boil but not superheat water at...
A counter current double pipe heat exchanger is used to boil but not superheat water at 100 DegreeC at rate of about 0.1 kg/s. This is achieved by flowing hot oil at 400 DegreeC through the inner pipe at a rate of 5 kg/s. Latent heat of water: 2265 kJ/kg Heat capacity of water: 4180 J/kgK Heat capacity of the oil: 1800 J/kgK What is the temperature of he hot oil leaving the heat exchanger? What is the overall heat...
Overall heat transfer co-efficient A pipe carrying milk at 4 °C without insulation will gain heat...
Overall heat transfer co-efficient A pipe carrying milk at 4 °C without insulation will gain heat from outside environment (with air temperature of 20 °C) before it reaches the cold storage containers from heat exchanger. If the pipe carrying the milk has thermal conductivity of 40 W/(m °C) with inside diameter of 5 cm and outside diameter of 7.5 cm, what is the maximum length of the pipe to limit rate of heat transfer to 1kW. Consider the convective heat...
Hot water enters a counter-flow double-pipe heat exchanger at 180F with a velocity of 5 ft/s....
Hot water enters a counter-flow double-pipe heat exchanger at 180F with a velocity of 5 ft/s. Cold water at 80F flows at 3 ft/s in the outer section of the exchanger. The diameter of the inner pipe is 1 inch, the pipe wall thickness is 1/8", and the outer pipe diameter is 2 inches. The overall heat transfer coefficient times area per unit length UA/L = 150 Btu/hr-ft-F. If the exchanger is 16 feet long, what is the exit temperature...
A parallel flow heat exchanger is used to transfer heat from hot water at 80oC, flowing...
A parallel flow heat exchanger is used to transfer heat from hot water at 80oC, flowing at 5 L/min to cold water at 15oC which is flowing at a rate of 15 L/min. The overall heat transfer coefficient is 2000 W/m2oC and the area is 0.2m2. Calculate the heat transfer rate, the outlet temperature of the cold water.
Cold water leading to a shower enters a well-insulated, thin-walled, double-pipe, counterflow heat exchanger at 10C...
Cold water leading to a shower enters a well-insulated, thin-walled, double-pipe, counterflow heat exchanger at 10C at a rate of 1.15kg/s and is heated to 70C by hot water that enters at 85C at a rate of 1.6kg/s. Use data from the tables to Determine the rate of entropy generation in the heat exchanger. Answer in kW/K.
The properties of the fluid are: density 895 kg/m3, viscosity 0.76 mNm-2s. A double-pipe heat exchanger...
The properties of the fluid are: density 895 kg/m3, viscosity 0.76 mNm-2s. A double-pipe heat exchanger is to be used to heat 6000 kg/h of 22 mol per cent hydrochloric acid. The exchanger will be constructed from karbate (impervious carbon) and steel tubing. The acid will flow through the inner, karbate, tube and saturated steam at 100ºC will be used for heating. The tube dimensions will be: karbate tube inside diameter 50 mm, outside diameter 60 mm; steel tube inside...
Problem 8.24 Water is used to cool ethylene glycol in a 60-ft-long double pipe heat exchanger...
Problem 8.24 Water is used to cool ethylene glycol in a 60-ft-long double pipe heat exchanger made of 4-std and 2-std (both type M) copper tubing. The water inlet temperature is 60°F and the ethylene glycol inlet temperature is 180°F. The flow rate of the ethylene glycol is 20 lbm/s, while that for the water is 30 lbm/s. Calculate the expected outlet temperature of the ethylene glycol and determine the pressure drop expected for both streams. Assume counterflow, and place...
A complex medium needs to be heated from 15°C to 37°C prior to use in mammalian...
A complex medium needs to be heated from 15°C to 37°C prior to use in mammalian cell culture. You are responsible for deciding the type of heat exchanger to adopt to achieve this heating. You are considering using a doublepipe heat exchanger with either co-current or counter-current flow. The medium flows through the inner tube and hot water enters the outer annulus at 80°C. You are given the following data: Cell culture medium: Mass flowrate = 2 kg s-1 Specific...
This is a heat transfer course, please explain and show work neatly, and please do not...
This is a heat transfer course, please explain and show work neatly, and please do not copy from any other solutions because they are incorrect. Thank you so much in advance Consider atmospheric air at a velocity of V = 20 m/s and a temperature of T= 20C, in cross flow over 10 mm square tube at 45 degrees, maintained at 50C. Sketch Assumptions Calculate the air properties (show the interpolation steps) Re = ? Nu = ? (reference the...