Question

A motor having a power factor of 0.8 absorbs an active power of 1200W, Calculate the...

A motor having a power factor of 0.8 absorbs an active power of 1200W, Calculate the reactive power drawn from the line. [2Marks](ii)A coil having a reactance of 10Ωand a resistance of 2Ωis connected in parallel with a capacitive reactance of 10Ω, If the supply voltageis 200V, then calculate the active power dissipated and the apparent power of the circuit. [3 Marks]

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
1. A circuit has a 400 resistance in one branch, a 50 inductive reactance in the...
1. A circuit has a 400 resistance in one branch, a 50 inductive reactance in the second and 40 capacitive reactance in the third. It is fed from a 240 V, 50 Hz supply. Find (a) Current in all branches (b) Total current (c) Circuit impedance (d) Circuit admittance (e) Power factor (f) Apparent power (g) Active power (h) Reactive power (i) Parameters of equivalent series circuit
Q1. A 3-phase, 400 V synchronous motor having a power consumption of 50 kW is connected...
Q1. A 3-phase, 400 V synchronous motor having a power consumption of 50 kW is connected in parallel with an induction motor which takes 200 kW at a power factor of 0·8 lagging. (i) Calculate the current drawn from the mains when the power factor of the synchronous motor is unity. (ii) At what power factor should the synchronous motor operate so that the current drawn from the mains is minimum.
The 400 V, 50 kVA, 0.8 power factor leading delta connected synchronous motor has synchronous reactance...
The 400 V, 50 kVA, 0.8 power factor leading delta connected synchronous motor has synchronous reactance of 3-ohm, resistance neglected. It is supplying a 12-kW load with initial power factor of 0.86 lagging. The windage and friction losses are 2.0 kW and the core losses are 1.5 kW. Determine (a) the motor efficiency; the line current; armature current; and excitation voltage. (b) If the flux of the motor is increased by 20 percent determine the excitation voltage; armature current; and...
A single-phase motor takes 8.3 A at a power factor of 0.866 lagging when connected to...
A single-phase motor takes 8.3 A at a power factor of 0.866 lagging when connected to a 230 V, 50 Hz supply. Two similar capacitors are connected in parallel with each other to form a capacitance bank. This capacitance bank is now connected in parallel with the motor to raise the power factor to unity. Determine the capacitance of each capacitor
Please be clear in concept and handwriting. A 20HP, three-phase, Wye-connected synchronous motor is connected to...
Please be clear in concept and handwriting. A 20HP, three-phase, Wye-connected synchronous motor is connected to a 277VAC, 60Hz power supply. At rated conditions, the motor runs at 3600 rpm and presents a 0.85 lagging power factor to the power supply. The per-phase armature reactance is 350m?. Armature resistance is negligible, as are all other sources of power loss. Considering rated conditions, a. draw a single-phase equivalent circuit showing V?, Ea and IA, with values. b. draw a phasor diagram...
A 2300-V, 400-hp, 60-Hz, 1200rpm, Y-connected synchronous motor has a rated power factor of 0.8 leading....
A 2300-V, 400-hp, 60-Hz, 1200rpm, Y-connected synchronous motor has a rated power factor of 0.8 leading. The efficiency of the motor is 90 % at full load. The armature resistance is 0.3 Ω, and the synchronous reactance is 3.55 Ω. Answer the following questions when it is operating at full load; Question 1 What is the number of poles in this motor? 2 4 6 8 10 12 Question 2 Find the output torque in Nm.(Assume 1hp=745.7W) 1985.7 2373.6 2011.9...
Three star-connected coils are drawing line current of 30A from a three phase supply. Also, total...
Three star-connected coils are drawing line current of 30A from a three phase supply. Also, total apparent and active powers of 25kVA and 11 kW respectively are absorbed by the coils. By assuming that the each coil is characterized by equal impedance, determine: i. the line and phase voltages ii. the total reactive power (1 mark) iii. the impedance of each coil. c) If the coils in Q2(b) are suddenly reconfigured into delta connection, calculate the new line currents and...
A 20 kVA single phase transformer 4800/480V has primary resistance and reactance of 5Ω and 15Ω...
A 20 kVA single phase transformer 4800/480V has primary resistance and reactance of 5Ω and 15Ω respectively, while the resistance and reactance of secondary winding is 0.1Ω and 0.15 Ω respectively. Calculate: (i) The parameter referred to primary side of transformer and draw the equivalent circuit (ii) The approximate value of secondary voltage at full load power factor of 0.8 lagging if 4.8kV primary supply
a 460-V 100-hp 60-Hz 4 pole Y connected synchronous motor has a operating power factor 0.85...
a 460-V 100-hp 60-Hz 4 pole Y connected synchronous motor has a operating power factor 0.85 leading the aramature resistance is o.2 ohms and synchronous reactance is 12 ohms at full load the efficiency is 85% find the sum of mechanical loss core loss and stray loss when meachine is operating at full load
THESE ARE QUESTION FROM THE TOPIC POWER FACTOR IMPROVEMENT FROM THE SUBJECT POWER SYSTEM FUNDAMENTALS PLEASE...
THESE ARE QUESTION FROM THE TOPIC POWER FACTOR IMPROVEMENT FROM THE SUBJECT POWER SYSTEM FUNDAMENTALS PLEASE DO THE QUESTIONS STEP BY STEP AND IN NEAT HAND WRITTING THE ANSWERS ARE GIVEN WITH THE QUESTIONS 1) . A station supplies 250 kVA at a lagging power factor of 0·8. A synchronous motor is connected in parallel with the load. If the combined load is 250 kW with a lagging p.f. of 0.9, determine : (i) the leading kVAR taken by the...