Question

where to install valves and filters in a pump network

where to install valves and filters in a pump network

Homework Answers

Answer #1

Filters are installed just below the pump inlet and above the reservoir. The purpose of the filter is, to filter the fluid which is taken from the reservoir and after filtering the fluid all the undissolved impurities gets filtered and pure form of fluid enters into the pump so that the pump will work effectively. We can also install the filters before the fluid is entering any critical component for proper working of system.

Valves are devices that are used to control the flow and direction of flow of fluid . The valves are installed after the pump and before the reciprocating cylinders or the actuators . The direction control valve changes the direction of flow entering into the cylinder and also for the flow Coming out of it. Check valves are installed before the directional control valve to control the flow before entering into it. The valves also prevent the back flow into the system and also regulates the pressure.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
An oil refinery is willing to install a 60,000-lb/hour pump for $325,000 in 2020 when the...
An oil refinery is willing to install a 60,000-lb/hour pump for $325,000 in 2020 when the pump index had a value of 500. the refinery must also install another pump of the same size in 2024. Economic data shows that the pump index is forecast to rise by 5% annually. What is the approximate cost of a new pump in 2024?
How and where do i find for a type of centrifugal pump together with a pump...
How and where do i find for a type of centrifugal pump together with a pump performance curve for my pipe network, if i have the pump head value,mass flow rate,pressure and density? how do i select a centrifugal pump for a certain pump head value? i also need to get a performance curve for that centrifugal pump
Metalfab Pump and Filter Inc. estimates that the cost of steel bodies for pressure valves will...
Metalfab Pump and Filter Inc. estimates that the cost of steel bodies for pressure valves will increase by $2 every 3 months. If the cost for the first quarter is expected to be $80, what is the present worth of the costs for a 5-year time period at an interest rate of 1.42% per quarter? The present worth is $  .
What are DHCP filters and how do they operate work on a network using Windows Server...
What are DHCP filters and how do they operate work on a network using Windows Server 2016? What is the "preference value" used to indicate when configuring DHCPv6 scopes and what does a preference value of zero mean? What must be done to a Windows Server before it can assign IPv6 addresses via DHCPv6?
how to calculate and plot a system curve for a pipe network with 1 pump? and...
how to calculate and plot a system curve for a pipe network with 1 pump? and how to find the operating point and the opening of the control valve at the normal flow rate? both the model problem and procedure
2. What is the difference between the structure of the atrioventricular valves and the semilunar valves?...
2. What is the difference between the structure of the atrioventricular valves and the semilunar valves? What is the function of each type of valve? 3. Where are the papillary muscles of the heart, and what do they look like?
A 10x10 image is the input to a convolutional neural network (CNN). The first hidden layer...
A 10x10 image is the input to a convolutional neural network (CNN). The first hidden layer of the CNN is comprised of 4 3x3 filters. Assuming zero-padding and bias, what is the dimensionality of the output from the first hidden layer and the number of parameters that are estimated from this layer? A 10x10 image is the input to a convolutional neural network (CNN). The first hidden layer of the CNN is comprised of 4 3x3 filters. Assuming bias but...
What is the sodium ions and potassium pump? Where do you find the pumps (which cells)?...
What is the sodium ions and potassium pump? Where do you find the pumps (which cells)? When the sodium-potassium pump is found, which ions do you find inside the cell? Which ions do you find outside of the cells? What is the importance of the pump to muscle physiology?
A heat pump will be used to heat a building where the average outside temperature is...
A heat pump will be used to heat a building where the average outside temperature is -1 degrees. There is a constant 80000 kJ / h heat loss from the building and it is desired that the building interior temperature is 20 degrees. The minimum power requirement of the heat pump operating according to the Reverse Carnot cycle is 10 kilowatts. According to this;     a) Find the heating effect coefficient of the heat pump.     b) Since the unit...
A pump curve provided by a manufacturer is given by h = 20[1 − (Q/100)2] where...
A pump curve provided by a manufacturer is given by h = 20[1 − (Q/100)2] where h is the head provided by the pump in meters and Q is the discharge in liters per minute. The system curve for a pumping application is h= 5+0.002Q2 (Q in liters per minute).Find the Operating point (Q) for •           one pump •           two pumps connected in series •           two pumps connected in parallel
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT