a-Calculate conventional yield effort at 0.2% (0.002 in./in.)
b- Tensile strength.
c- The modulus of elasticity.
d- Elongation
e- The reduction in area.
f- The engineering effort to fracture
g- The real stress to fracture
h- The modulus of resilience
Copper alloy
Load (N) | Calibrated length (mm) |
0 | 40.00000 |
25000 | 20.01850 |
50000 | 40.037 |
75000 | 40.0555 |
90000 | 40.2000 |
105000 | 40.6 |
120000 | 41.56 |
131000 | 44 |
125000 | 47.52 |
- Initial diameter of the test tube: 20mm
- Initial calibrated length: 40mm
- Calibrated length after fracture: 47.42mm
- Diameter after fracture. 18.35mm