Question

An air-conditioning system with a room design 22 degrees C DBT & 50% RH has a...

An air-conditioning system with a room design 22 degrees C DBT & 50% RH has a room sensible heat 35 kW with 0.8 sensible heat factor. Determine:

a. Draw the psychrometric chart indicating all parameters; room condition, SHF, room ADP & all temperatures & humidity

b. Room latent heat in kW

c. Room apparatus dew point

d. Supply cmm of air at the room apparatus dew point.

e. Supply cmm and specific humidity for a supply air 16 deg C

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
The design data for an air-conditioning plant of a restaurant is given below Outdoor design conditions...
The design data for an air-conditioning plant of a restaurant is given below Outdoor design conditions = 35ºC DBT and 24ºC WBT Indoor design conditions = 27ºC DBT and 55% RH Seating capacity of the restaurant = 50 Latent heat gain per person = 44 W Latent heat gain from meals per person = 6 W Sensible heat gain per person =58 W Sensible heat gain from meals per person = 3.5 W Number of service employees = 5 Latent...
The following data is available for the design of air conditioning of a small theatre: Outdoor...
The following data is available for the design of air conditioning of a small theatre: Outdoor design conditions = 34ºC DBT and 70% RH Comfort conditions required = 22ºC DBT and 50% RH Total seating capacity = 350 persons Sensible heat gain per person = 90 W Latent heat gain per person = 30 W Sensible heat due to solar gain and infiltrated air = 46.6 kW Latent heat gain due to infiltrated air = 23.3 kW Fresh air supplied...
For an infiltration rate of 1.32 air changes per hour (ACH), determine sensible, latent, and total...
For an infiltration rate of 1.32 air changes per hour (ACH), determine sensible, latent, and total infiltration heat load of a building at sea level, in kW, that is 20 m long, 13 m wide, and 3 m high when the outdoor air is at 32°C and 35 percent relative humidity. The building is maintained at 24°C and 55 percent relative humidity at all times. The gas constant and the specific heat of air are R = 0.287 kPa·m3/kg·K and...
QUESTION 1 The term "Slip" indicates the difference between the motor's synchronous speed and the no-load...
QUESTION 1 The term "Slip" indicates the difference between the motor's synchronous speed and the no-load speed True False 1 points    QUESTION 2 Wet Bulb (WB) Temperature: is for the temperature reading form an ordinary mercury bulb thermometer or regular temperature sensor. True False 1 points    QUESTION 3 The refrigerant (R-134a) is the new replacement of the refrigerant (R-22) as it is less harmful to the environment. True False 1 points    QUESTION 4 Draft Gauge and Bourdon...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT