Question

A synchronous generator and motor are rated 30,000kVA, 13.2kV, and both have subtransient reactances of 20%....

A synchronous generator and motor are rated 30,000kVA, 13.2kV, and both have subtransient reactances of 20%. The line connecting them has a reactance of 10% on the base of the machine ratings. The motor is drawing 20,000kW at 0.8 power-factor leading and a terminal voltage of 12.8kV when a symmetrical three phase fault occurs at the generator terminals. Find

A synchronous generator and motor are rated 30,000kVA, 13.2kV, and both have subtransient reactances of 20%. The line connecting them has a reactance of 10% on the base of the machine ratings. The motor is drawing 20,000kW at 0.8 power-factor leading and a terminal voltage of 12.8kV when a symmetrical three phase fault occurs at the generator terminals.Find
(a) the subtransient currents in the generator and the motor
(b) the subtransient fault current
(c) the fault current contributions from the generator and motor.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 125 MVA 11 kV three phase 50 Hz synchronous generator has a synchronous reactance of...
A 125 MVA 11 kV three phase 50 Hz synchronous generator has a synchronous reactance of 1.33 p.u. The generator achieves rated open circuit voltage at a field current of 325 A. The generator is connected to a network with an equivalent line-line voltage of 11 kV and an equivalent impedance of 0.17 pu on the generator base. The generator is loaded to a real power of 110 MW. a- Find the generated voltage Eaf in p.u. such that the...
A 200kVA, 480v, 50Hz, star connected synchronous generator with a rated field current of 5A was...
A 200kVA, 480v, 50Hz, star connected synchronous generator with a rated field current of 5A was tested at rated speed and the following data were taken: 1. The open circuit terminal voltage of the generator was 540v at rated field current. 2. The short circuit line current was 300A at rated current. 3. With the machine at standstill, a dc voltage of 10v was applied between two of the generator terminals, a current of 25A was measured. Determine the values...
A 300MVA, 20KV three-phase generator has a sub-transient reactance of 20%. The generator supplies two parallel...
A 300MVA, 20KV three-phase generator has a sub-transient reactance of 20%. The generator supplies two parallel synchronous motors (M1 and M2) over a 100km transmission line. The line has two transformers T1 and T2 at the beginning and at the end of the line respectively. Both motors are rated at 13.0KV with X"=20%. Motor M1 has a rated input of 100MVA and M2 has a rated input of 50MVA. The transformer T1 is rated 350MVA, 20/230KV and T2 is rated...
A submarine has a 3-phase, Y-connected, 2- pole, 60Hz synchronous generator rated to deliver 1687.5 kVA...
A submarine has a 3-phase, Y-connected, 2- pole, 60Hz synchronous generator rated to deliver 1687.5 kVA at a FP = 0.8 lagging with a line voltage of 450-V. The machine stator resistance RS = 0.004 ?. The synchronous reactance is Xs=0.08 ?. The actual system load on the machine draws 900 kW at FP = 0.6 lagging. Assume that a voltage regulator has automatically adjusted the field current so that the terminal voltage is its rated value. Mechanical losses are...
There is a synchronous generator with a rated output of 100 MVA. At rated output, voltage...
There is a synchronous generator with a rated output of 100 MVA. At rated output, voltage 6600v, power factor 85%, efficiency 98%. Answer the questions below... 1- Voltage per phase for Y connection 2- Output current 3- Magnitude of mechanical power input to generator in (MW)
A 42 kVA three-phase synchronous generator with line voltage 4.16 kV at a frequency of 60...
A 42 kVA three-phase synchronous generator with line voltage 4.16 kV at a frequency of 60 Hz, is connected in star configuration. The generator has a winding whose armature resistance is 0.8 Ω and a synchronous reactance of 7.4 Ω, both per phase. Determine the voltage regulation when the power factor is 0.600 lagging.
A 75-kW, 440-V, 0.8-PF-leading Y-connected synchronous generator has an armature resistance of 0.22 Ω and a...
A 75-kW, 440-V, 0.8-PF-leading Y-connected synchronous generator has an armature resistance of 0.22 Ω and a synchronous reactance of 3.0 Ω. Its efficiency at full load is 89% (1 Hp=746 watt). (a) What is the line current of the generator at rated conditions? (b) What is the internal generated voltage EA of this motor at rated conditions?
A three-phase, 9,375 kVA, 13.8 kV, 4-pole, 60 Hz, Y-connected synchronous generator has a synchronous reactance,...
A three-phase, 9,375 kVA, 13.8 kV, 4-pole, 60 Hz, Y-connected synchronous generator has a synchronous reactance, Xs = 17.9, and is connected to an infinite bus at rated voltage. If the rotational and electrical losses are negligivle, what is Ia, Ef, delta, theta, Tdrive, Phasor diagram, and power flow diagram (label completely with numerical values for, A) the machine as a generator; the prime-throttle is opened and If is adjusted so that the machine delivers rated kVA, 0.8 pf lagging,...
The test results of a three-phase synchronous generator with the rated voltage of 6,600V and the...
The test results of a three-phase synchronous generator with the rated voltage of 6,600V and the capacity of 50 MVA are as follows. No-load test result: When the terminal voltage was 6,600V, the field current was 1280A. Short circuit test result: The field current required to flow the rated current was 1600A. Find the rated current of this generator Find the short-circuit ratio. However, the second decimal shall be rounded off to obtain the first decimal Find the synchronous reactance....
A balanced, symmetrical, round-rotor, 3-phase, 60 Hz, 2-pole, 100MVA, 13.8kV, synchronous generator is being driven at...
A balanced, symmetrical, round-rotor, 3-phase, 60 Hz, 2-pole, 100MVA, 13.8kV, synchronous generator is being driven at synchronous speed. During tests, an IFNL (field current required to produced rated terminal voltage under open circuit) of 150A and an IFSC (field current required to produced rated armature current under short circuit) of 100A were obtained. Use a linear model and neglect the armature resistance for the following calculations. a) What field current is needed to maintain rated terminal voltage when the generator...