Question

draw three phase autotransformer step up and step down (show the difference) with voltage magnitude and...

draw three phase autotransformer
step up and step down (show the difference) with voltage magnitude and current directions

Homework Answers

Answer #1

As shown in the figure it is 3-phase step down Autotransformer which is used to compensate voltage drops as the there is series winding you can see the current directions and voltage magnitude as well.

As you can see this is 3-phase step up Autotransformer which shows the voltage magnitude as reverse of step down transformer and the current directions as well.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V...
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V . The source is connected to a balanced Y-connected load by a distribution line that has an impedance of 0.1+0.8i Ω/ϕ . The load impedance is 20.2+14.8i Ω/ϕ . The phase sequence of the source is acb. Use the a-phase voltage of the source as the reference. Part A: Specify the magnitude and phase angle of the line current IaA. Part B: Specify the...
A step-down transformer can step down the input voltage down to a lower voltage. Imagine a...
A step-down transformer can step down the input voltage down to a lower voltage. Imagine a step-down transformer whose input is 2.5-kV supplies a load with 80 A. The primary winding is N1, the secondary winding is N2, and the ratio N1/N2 is 20. Calculate the power output in kW.
A single phase 60 Hz two-winding power transformer is rated at 2400V/240V and 100 kVA. If...
A single phase 60 Hz two-winding power transformer is rated at 2400V/240V and 100 kVA. If an autotransformer is built from this conventional transformer to supply a load at 2400V with supply voltage 2640V. Draw the autotransformer and calculate the voltage, current and apparent power rating of the auto transformer. Also calculate the apparent power rating advantage of autotransformer over conventional transformer.
what is the phase difference in phase angle between induced voltage and current in a PMSM...
what is the phase difference in phase angle between induced voltage and current in a PMSM controlled to keep maximum torque per amp?
Problem 4: A single phase 60 Hz two-winding power transformer is rated at 2400V/240V and 100...
Problem 4: A single phase 60 Hz two-winding power transformer is rated at 2400V/240V and 100 kVA. If an autotransformer is built from this conventional transformer to supply a load at 2400V with supply voltage 2640V. Draw the autotransformer and calculate the voltage, current and apparent power rating of the auto transformer. Also calculate the apparent power rating advantage of autotransformer over conventional transformer.
Draw the Bode plot of magnitude and phase for the following system. Find the magnitude at...
Draw the Bode plot of magnitude and phase for the following system. Find the magnitude at corner frequencies. G(s)=10^2(s+30)(s/10+30)^2/(s+3)2 In moodle write down the corner frequencies and the exact magnitude at corner frequencies
Three single phase transformers having a 15:1 ratio are wye-connected to a 2400 V three phase...
Three single phase transformers having a 15:1 ratio are wye-connected to a 2400 V three phase line as a step-down transformer. What is the line voltage of each transformer? What is the secondary voltage of each transformer if they are delta connected to the same line?
A wye connected three-phase source is delivering a line voltage of 480 V at a line...
A wye connected three-phase source is delivering a line voltage of 480 V at a line current of 25 amperes. Find a) the phase voltage b) the phase current c) the line voltage d) the line current e) the total power delivered.
When starting up the motor (turning up the variac and the 3-phase voltage) what happens to...
When starting up the motor (turning up the variac and the 3-phase voltage) what happens to the input current?  What is the per unit value of the highest current? What is the condition of the motor before it begins to turn (open circuit, short circuit)? What element in the circuit model is affected?
Q3/ Draw the out voltage and current waveforms of a single-phase cycloconverter connected to a purely...
Q3/ Draw the out voltage and current waveforms of a single-phase cycloconverter connected to a purely resistive load. The following information could be useful: Load Supply Voltage, Supply Frequency Output Frequency Firing Angle At 20Ω 230Vrms , 50 Hz 12.5 1/300 sec Your drawing should contain all the details including Amplitudes, Time, Degrees and Axis Names.
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question