Question

A permanent magnet DC motor with Kv = 0.7V-s is tested under the following two conditions:...

A permanent magnet DC motor with Kv = 0.7V-s is tested under the following two conditions:

Test 1: Apply 120V; motor is unloaded, Ia = 2A and ?=160 rad/s

Test 2: Apply 120V: increase load torque until Ia = 6A and ?=137.1 rad/s Find the mechanical torque loss and the load torque in test 2. Assume mechanical torque loss is constant (independent of speed).

TMECH LOSS = __________

TLOAD = __________

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A permanent magnet DC motor is supplied with 24V and 2A, and is operating at 1500...
A permanent magnet DC motor is supplied with 24V and 2A, and is operating at 1500 rpm. The motor is 85% efficient under these conditions. Assume no rotational losses. Find the machine constant Kv. Find the back EMF at 1500 rpm. KV = __________ Ea = __________
A 5 HP, 120V DC motor has an efficiency of 92%. The machine constant Kv is...
A 5 HP, 120V DC motor has an efficiency of 92%. The machine constant Kv is 0.138V-s. Mechanical losses are 112 W. find: a. Current b. Armature resistance c. Rated speed (rpm)
A permanent magnet DC generator is run at a constant speed of 800 rpm and provides...
A permanent magnet DC generator is run at a constant speed of 800 rpm and provides a terminal voltage of 150 V at its rated loading. Its armature resistance is Ra=0.2 Ω. When the generator is not loaded, the input power is 300W and Vt= 165V. a) Calculate the voltage regulation of the generator. b) Calculate the armature current. For the same machine given assume now that it is loaded with a load of RL= 0.35 Ω. c) Calculate the...
A 200 V DC, 1,800 RPM shunt connected motor has an armature resistance of 0.4 ohm...
A 200 V DC, 1,800 RPM shunt connected motor has an armature resistance of 0.4 ohm and a brush resistance of 0.4 ohm; brush voltage drop of 6.0 V, independent of load. The resistance of the shunt field is 230 ohm. The full load rated line current is 40 A. When the motor is operated at no load the line current is 5 A and the speed is 1750 RPM. Calculate speed at rated load Calculate speed at .3 rated...
The following test data apply to a 7.5-hp, three-phase, 220-V, 19-A,60-Hz, four-pole induction motor with a...
The following test data apply to a 7.5-hp, three-phase, 220-V, 19-A,60-Hz, four-pole induction motor with a double-squirrel-cage rotor of design class C (high-starting-torque, low-starting current type): Test 1: No-load test at 60 Hz; Applied voltage V = 219 V line-to-line; Average phase current I1,nl = 5.70 A; Power Pnl =380 W; Test 2: Blocked-rotor test at 15 Hz; Applied voltage V = 26.5 V line-to-line; Average phase current ll,bl = 18.57 A; Power Pbl = 675 W; Test 3: Average...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT