Question

The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These...

The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These are the default values of the "Asynchronous Machine" model in MATLAB Simulink. r1=0.5968 Ω; r2=0.6258 Ω; L1=0.0003495 H; L2=0.005473 H; Lm=0.0354 H; Stator line voltage = 400 V rms. The motor for rotor speeds nm= 0 to 1500 rpm.

X1= 0.1097 ohm, X2= 1.719 ohm , Xm= 11.12 ohm, RTH = 0.5853 , XTH = 0.1395 and

VTH = 230.82 V.

Suppose the motor is to rotate a load with constant torque of τm =100 N.m. Then use MATLAB to plot the torque-speed characteristic of the load. What would be the motor speed and torque?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These...
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These are the default values of the “Asynchronous Machine” model in MATLAB Simulink. r1=0.5968 ?; r2=0.6258 ?; L1=0.0003495 H; L2=0.005473 H; Lm=0.0354 H; Stator line voltage = 400 V rms. The motor for rotor speeds nm= 0 to 1500 rpm. X1= 0.1097 ohm, X2= 1.719 ohm , Xm= 11.12 ohm, RTH = 0.5853 , XTH = 0.1395 and VTH = 230.82 V. Suppose the motor...
A three phase Wye-connected 460 v, 4 poles, 60 Hz wound rotor induction motor has the...
A three phase Wye-connected 460 v, 4 poles, 60 Hz wound rotor induction motor has the following parameters: R1=0.3, R2=0.15, X1=0.5, X2=0.2, Xm=14 The total friction, windage, and core loss is constant at 400 w. The motor is working at its rated voltage and drives its load at 1764 rpm. a)Calculate the input current and the input power. b)Calculate the output mechanical power and torque and motor efficiency. c)Calculate the starting current of this motor and compare it with its...
Calculate full load torque developed by an 8 pole, 50 Hz, 3 phase IM Motor operating...
Calculate full load torque developed by an 8 pole, 50 Hz, 3 phase IM Motor operating with 4 % slip on full load. Motor develops Max. Torque at a speed of 700rpm. The rotor resistance of motor is 0.5 ohm per phase. Standstill rotor emf is 120v per phase.
A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full...
A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. What is the output power of this motor in kW? If friction and windage loss is 350 watts, what is the gross mechanical output at full load? What is the gross torque of this motor at full load? What is the rotor cupper loss at full load? If the efficiency of this motor is 90% at full load what is...
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a...
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. a)-What is the synchronous speed of this motor? b)-What is the shaft speed of this motor at full load? c)-What is the frequency of rotor current at full load? d)-What is the shaft torque of this motor at full load? e)-If the efficiency of this motor is 90% at full load what is the input power f)-If the efficiency...
Q1. A 440 V, 60 Hz, six-pole, 3 phase induction motor is taking 50 kVA at...
Q1. A 440 V, 60 Hz, six-pole, 3 phase induction motor is taking 50 kVA at 0.8 power factor and is running at a slip of 2.5 percent. The stator copper losses are 0.5 kW and rotational losses are 2.5 kW. i) The rotor copper losses ii) The shaft hp iii) The efficiency iv) The shaft torque
A 3-phase 50Hz 2-pole 440V (L-L rms) induction motor drive has a rated speed of 2955...
A 3-phase 50Hz 2-pole 440V (L-L rms) induction motor drive has a rated speed of 2955 rpm and rated torque of 35 Nm. This motor drives a load with a torque characteristic that increases linearly with speed such that it equals the load torque at the rated speed. It draws a current of 3.0 A(rms) per phase at the rated voltage at a power factor of 0.81 (lagging). The stator resistance Rs = {r_s} ohms. At the rated operating speed,...
A 37.3 kW, 3 phase, 4 pole, 50 Hz, induction motor has a full load efficiency...
A 37.3 kW, 3 phase, 4 pole, 50 Hz, induction motor has a full load efficiency of 85%. The friction and windage losses are one third of the no load losses and the copper loss equals the iron loss at full load. Find the full load speed. Stator resistance may be neglected. [Answer: 1401.3 rpm]
A 230 volt, 60 Hz, 4 pole star connected, three phase induction motor operates at a...
A 230 volt, 60 Hz, 4 pole star connected, three phase induction motor operates at a full load speed of 1710 rpm. The power developed at this speed is 2 horse power. If the supply voltage fluctuates ±10%, determine the torque range of the motor.
The following test data apply to a 7.5-hp, three-phase, 220-V, 19-A,60-Hz, four-pole induction motor with a...
The following test data apply to a 7.5-hp, three-phase, 220-V, 19-A,60-Hz, four-pole induction motor with a double-squirrel-cage rotor of design class C (high-starting-torque, low-starting current type): Test 1: No-load test at 60 Hz; Applied voltage V = 219 V line-to-line; Average phase current I1,nl = 5.70 A; Power Pnl =380 W; Test 2: Blocked-rotor test at 15 Hz; Applied voltage V = 26.5 V line-to-line; Average phase current ll,bl = 18.57 A; Power Pbl = 675 W; Test 3: Average...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question