Question

Assume that a 60 Hz, 200 kVA, transformer is an ideal transformer with a turn ration...

Assume that a 60 Hz, 200 kVA, transformer is an ideal transformer with a turn ration of a = 1/15 and primary voltage of 110 VAC then determine the following:

1. Its Secondary side voltages .

2. The value of load current (i.e., I2), if a load impedance connected to its secondary terminals makes the transformer fully loaded.

3. The value of the primary-side current.

4. The value of the load impedance referred to the primary side of the transformer.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A single phase transformer rated at 3000 KVA, 69kV, 60 Hz has a total internal impedance...
A single phase transformer rated at 3000 KVA, 69kV, 60 Hz has a total internal impedance Zp of 127ohm, referred to the primary side. Calculate: a) primary and secondary currents b) voltage regulation from no load to full load for 2000 kW resistive load, knowing that the primary voltage supply is fixed at 69 kV. c) primary and secondary currents if the secondary is accidentally short circuited.
A 2.2 KVA, 440---220 V, 60 Hz, step-down transformer has the following parameters: Rp= 3.0 Ω,...
A 2.2 KVA, 440---220 V, 60 Hz, step-down transformer has the following parameters: Rp= 3.0 Ω, Xp= 4.0 Ω, Rs= 2.5 Ω, Xs= 2.0 Ω, Rc= 60 KΩ, and Xm = 15 KΩ. The transformer is operating at full load with a power factor of 0.707 lagging. The magnetizing branch impedance can be ignored. a) Draw the transformer’s equivalent T-circuit, b) Find the equivalent winding impedance referred to the high side, c) Calculate the primary and secondary currents, d) Determine...
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is...
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is rated at 1000 kVA and has a step-down ratio of 8:1. The bank supplies a balance load having a power factor of 0.8 lag with a load current of 70 A. Assume ideal transformer, determine. The primary line and phase voltages The secondary line and phase voltages The secondary line and phase currents The apparent and active power at the load Total kVA capacity...
A 20 kVA single phase transformer 4800/480V has primary resistance and reactance of 5Ω and 15Ω...
A 20 kVA single phase transformer 4800/480V has primary resistance and reactance of 5Ω and 15Ω respectively, while the resistance and reactance of secondary winding is 0.1Ω and 0.15 Ω respectively. Calculate: (i) The parameter referred to primary side of transformer and draw the equivalent circuit (ii) The approximate value of secondary voltage at full load power factor of 0.8 lagging if 4.8kV primary supply
An AC source of rms voltage 50 V and frequency 150 Hz is connected to the...
An AC source of rms voltage 50 V and frequency 150 Hz is connected to the primary coil of a transformer that has 5000 turns on the primary side and 7500 turns on the secondary side. If the secondary coil is connected to a 150 ohm load, determine the current flowing through the primary coil. 0.75 A 1.25 A 0.25 A 0.50 A
Plate values ​​of a three-phase transformer are given below: 1600 kVA, 15 kV / 400 V,...
Plate values ​​of a three-phase transformer are given below: 1600 kVA, 15 kV / 400 V, 50 Hz, io = 1.2%; ukN = 6%, idle losses 2450 W, rated copper losses of power 14500 W; Dy5. a) Calculate primary and secondary line and phase currents. b) Secondary at 75% load in power factor with 0.85 inductance and 0.85 capacity calculate the voltage separately. Compare and interpret the results. capacity at what time of day can the upload be seen? To...
Plate values ​​of a three-phase transformer are given below: 1600 kVA, 15 kV / 400 V,...
Plate values ​​of a three-phase transformer are given below: 1600 kVA, 15 kV / 400 V, 50 Hz, io = 1.2%; ukN = 6%, idle losses 2450 W, rated copper losses of power 14500 W; Dy5. a) Calculate primary and secondary line and phase currents. b) Secondary at 75% load in power factor with 0.85 inductance and 0.85 capacity calculate the voltage separately. Compare and interpret the results. capacity at what time of day can the upload be seen? To...
An ideal transformer has 6,000 windings in its primary coil and 10,000 windings in its secondary...
An ideal transformer has 6,000 windings in its primary coil and 10,000 windings in its secondary coil. The primary coil is connected to an RMS voltage of 480 volts. The secondary coil is connected to a single 8,000 Ω resistor. What is the current through the primary coil?
A transformer has a primary-to-secondary turns ratio of 100:1. The voltage on the primary side is...
A transformer has a primary-to-secondary turns ratio of 100:1. The voltage on the primary side is 27.7 kv.a.c. at 60.0 Hz ( assume 60.0 Hz when treating electric power topics). A load is connected across the secondary winding. Assume that the transformer is ideal. (a) Suppose that the electric utility supplied 27.7 kv.d.c. rather than 27.7 kv.a.c. How much power would the transformer’s secondary winding deliver to the load in this case? (b). The transformer’s primary winding is supplied by...
An ideal step-down transformer has a primary coil of 370 turns and a secondary coil of...
An ideal step-down transformer has a primary coil of 370 turns and a secondary coil of 25 turns. Its primary coil is plugged into an outlet with 115 V(AC), from which it draws an rms current of 0.69 A. What is the voltage in the secondary coil? Calculate the rms current in the secondary coil. Assuming that the transformer secondary is driving a resistive load, calculate the average power dissipated in the resistor.
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT