Question

At the interface between two materials with different permeabilities, ?1 and ?2, a ??current with density...

At the interface between two materials with different permeabilities, ?1 and ?2, a ??current with density of K flows. If the magnetic field tangential to the interface exists only in material 1, determine an expression for the current density at the interface in terms of the permeabilities and the magnetic field.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A light beam strikes an interface between two materials as shown below. The angle of incidence...
A light beam strikes an interface between two materials as shown below. The angle of incidence =56 degrees and the angle of  refraction =39 degrees. If the index of refraction of material 1 is 1.3, what is the index of refraction of material 2?
A wire of radius R carries a non-uniform current described by the current density J =...
A wire of radius R carries a non-uniform current described by the current density J = A r^3 where r is the radial distance from the center of the wire 1 write an expression for the total current that flows through the wire in terms of the parameters A, R, and constants. 2) What is the magnetic field B in the region r < R. Be sure to specify the direction of the field. 3) A positive charge is moving...
A two meter long thin rod is composed of two different materials (fused together). Metal 1...
A two meter long thin rod is composed of two different materials (fused together). Metal 1 is 0.6 meter long and metal 2 is 1.4 meter long. Metal 1 linear mass density is 5g/cm and metal 2 linear mass density is 4g/cm. Where is the center of mass located for this two meter long rod?
1) A 64 liter tank of an ideal gas at a constant temperature T= 318 K...
1) A 64 liter tank of an ideal gas at a constant temperature T= 318 K and a pressure of 276 atm develops a leak. After the leak was discovered, the pressure was reduced to 120 atm. How many moles of the gas escaped? 2) Assume a rectangular strip of a material with an electron density of n=5.8x1020 cm-3. The strip is 7 mm wide and 0.7 mm thick. A current of 6 A flows through the strip. The Hall...
a. A 3 m long wire carrying a current of 1. 06 Ampere forms a 2-turn...
a. A 3 m long wire carrying a current of 1. 06 Ampere forms a 2-turn loop in the shape of an equilateral triangle. If the loop is placed in a constant uniform magnetic field with a magnitude of 0.734 T, determine the maximum torque that acts on it. b. Given an iron core solenoid with 16 turns of wire, 38 cm long and diameter of 99 cm. When 48A current flows in the wire, it was found that the...
An infinitely large positively charged nonconducting sheet 1 has uniform surface charge density σ1 = +130...
An infinitely large positively charged nonconducting sheet 1 has uniform surface charge density σ1 = +130 nC/m2 and is located in the xz plane of a Cartesian coordinate system. An infinitely large positively charged nonconducting sheet 2 has uniform surface charge density σ2 = +90.0 nC/m2 and intersects the xz plane at the z axis, making an angle θ = 30∘ with sheet 1. Part A Determine the expression for the electric field in the region between the sheets for...
A mass spectrometer is a device for separating particles of different masses from a mixture. For...
A mass spectrometer is a device for separating particles of different masses from a mixture. For example, the technology is used to investigate qualitative and quantitative changes within thousands of biologically active components such as proteins, lipids and metabolites. A mass spectrometer consists of three sections: The accelerator The velocity selector The magnetic chamber (1) Accelerator (acc): In the accelerator, there is only an uniform Electric field due to a potential difference Vacc across two vertical plates separated from a...
A mass spectrometer is a device for separating particles of different masses from a mixture. For...
A mass spectrometer is a device for separating particles of different masses from a mixture. For example, the technology is used to investigate qualitative and quantitative changes within thousands of biologically active components such as proteins, lipids and metabolites. A mass spectrometer consists of three sections: The accelerator The velocity selector The magnetic chamber (1) Accelerator (acc): In the accelerator, there is only an uniform Electric field due to a potential difference Vacc across two vertical plates separated from a...
Two long, straight, parallel wires carry current. The first wire carries I1 = 3 A to...
Two long, straight, parallel wires carry current. The first wire carries I1 = 3 A to the right and the second carries I2 = 5 A to the left. The force per length each wire exerts on the other is of magnitude 5 × 10−6 N/m. (a) Sketch the situation. On your sketch indicate the directions of the magnetic fields produced by each wire and the direction of the force exerted on each wire. Determine the distance between the wires....
As shown in the figure below, two long parallel wires (1 and 2) carry currents of...
As shown in the figure below, two long parallel wires (1 and 2) carry currents of I1 = 3.32 A and I2 = 4.50 A in the direction indicated. Two parallel wires point into the page. They are a distance d apart from each other, with the left wire labeled I_1 at the origin and the right wire labeled I_2 a distance d along the positive x-axis. There is a point labeled P directly above wire I_1 a distance d...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT