Question

A 100 km long, three phase 50 hz transmission line has resistance per phase per km...

A 100 km long, three phase 50 hz transmission line has resistance per phase per km of 0.1 ohms, reactance per phase per km of 0.5 ohms, susceptance per phase per km of 10 x 10-6 siemens. If the line supplies a load of 20 MW at 0.9 pf lagging at 66 KV at the receiving end, calculate the regulation and efficiency of the line using the following assumptions:

a. nominal pi vector solution

b. nominal T vector solution

c. using end condenser method

d. using the ABCD constant of a long transmission line.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
1- A 69-kV, three-phase short transmission line is 16 km long. The line has a per...
1- A 69-kV, three-phase short transmission line is 16 km long. The line has a per phase series impedance of 0.125 + j0.4375 ohm per km. Determine the sending end voltage, voltage regulation, the sending end power, and the transmission efficiency when the line delivers a. 70 MVA, 0.8 lagging power factor at 64 kV b. 120 MW, unity power factor at 64 kV 2-three-phase, completely transposed 345-kV, 200 km line has two 795,000- cmil 26/2 ACSR conductor per bundle...
1- 30-kV, three-phase transmission line has a per phase series impedance of z = 0.05+j0.45 ohm...
1- 30-kV, three-phase transmission line has a per phase series impedance of z = 0.05+j0.45 ohm per Km and a per phase shunt admittance of y = j3.4x10-6 siemens per km. The line is 80 km long. Using the nominal π model, determine a The transmission line ABCD constants. b Find the sending end voltage and current, voltage regulation, the sending end power and the transmission efficiency when the line delivers 1. 200 MVA, 0.8 lagging power factor at 220...
A 250 km , three- phase , 50 Hz transmission line is delivering 25 MVA at...
A 250 km , three- phase , 50 Hz transmission line is delivering 25 MVA at 0.8 lagging power factor to a balanced load at 132 KV ( line-line) . The conductor resistance is 0.11 ohm/km . The line inductance per phase is 1.24 mH/km and the line to neutral capacitance is given as 9.4 x 10 – 9 F/km. a ) find the nominal – Л representation. b) find the sending end voltage , VS by nominal – Л...
A three-phase overhead transmission line is 300-km long, 60-Hz, the ABCD constants of the transmission line...
A three-phase overhead transmission line is 300-km long, 60-Hz, the ABCD constants of the transmission line are: A = D = 0.9313∠0.209° B = 97.0 ∠87.2° C = j1.37 * 10-3 Assume a 266.1-Ω surge impedance, a 5000 km wavelength, and VS = VR = 765 kV. Neglecting line losses, find the following: a) The phase change constant; b) Surge Impedance Loading
A three-phase 12-mile, 50 kV (line), 60 Hz line has a resistance of 0.1, capacitance of...
A three-phase 12-mile, 50 kV (line), 60 Hz line has a resistance of 0.1, capacitance of 0.01 and inductance of 1 mH/km. The load at the receiving end of the line absorbs 10 MVA at 90 percent of rated voltage. Calculate: ABCD parameters of the line The sending-end voltage if the load power factor is 0.8 lagging. The sending-end line voltage, line current and complex power if the load has a power factor of 0.7 leading.
A 100 MVA, 13.2 kV three phase generator (G) having a synchronous reactance of 10% is...
A 100 MVA, 13.2 kV three phase generator (G) having a synchronous reactance of 10% is connected to a three phase Y-Y transformer T1 which feeds a 132 kV 10 miles transmission line having an impedance per phase of 2 + j5 ?/mile. At the receiving end of the transmission line is a Y-Y step down transformer T2. Three loads are connected to the secondary side of the transformer T2. Loads are as follows: Load#1 40 MVA at 0.8 pf...
a 200km, 300kv, 50Hz transmission line has a reactance of 0.4 ohms per km and a...
a 200km, 300kv, 50Hz transmission line has a reactance of 0.4 ohms per km and a distributed capacitance of 400000 ohms per km. Draw an equivalent circuit of the line per phase. Calculate the line current per phase at the sender end when the receiver is open. What is the reactive power supplied to the sender?
A 33 kV, three-phase, 50 Hz line of resistance 2 Ω/ph and reactance j9 Ω/ph supplies...
A 33 kV, three-phase, 50 Hz line of resistance 2 Ω/ph and reactance j9 Ω/ph supplies a 33 kV/440 V transformer having negligible resistance and reactance of j2 Ω/ph referred to 33 kV. The transformer supplies a 440 V feeder of resistance 0.01 Ω/ph and reactance j0.007 Ω/ph. If VR, the receiving-end voltage, is 440 V, calculate VS, the sending-end voltage, when the three-phase load delivered is 440 kW at unity power factor.          
a) A three phase transformer rated at 30 MVA 10 kV(Δ)/1 kV(Y) is supplying a load...
a) A three phase transformer rated at 30 MVA 10 kV(Δ)/1 kV(Y) is supplying a load at the low voltage side. The load absorbs 5 MVA, 0.7 power factor lagging at line to line voltage 0.9 kV. The transformer has an equivalent reactance 0.05 Ω/phase. Assuming 10 MVA and 1 kV as base value, draw the per unit diagram for the system. Find the Line to Line voltage at the primary side of the transformer. b) A three-phase synchronous generator...
A 3-phase, 5 MVA, kV, 60 Hz synchronous machine has a synchronous reactance of 10 ohms...
A 3-phase, 5 MVA, kV, 60 Hz synchronous machine has a synchronous reactance of 10 ohms per phase. The machine is connected to kV, 60 Hz bus and is operated as synchronous condenser (synchronous motor at no-load condition) a. For normal excitation (excitation voltage terminal voltage), find the line current. Draw the phasor diagram b. If the excitation is increased to 150% of the normal excitation, find the line current and reactive power delivered or absorbed by the bus. Draw...