Question

A 2-pole, 3-phase induction motor has the following physical dimensions: radius r=7cm, length l=9cm, and the...

A 2-pole, 3-phase induction motor has the following physical dimensions: radius r=7cm, length l=9cm, and the air gap length lg=0.5mm. Calculate the magnetizing inductance Lm for this machine, if it was designed such that the peak of the flux-density distribution does not exceed 0.8T when the rated voltages of 208V (line-line, rms) are applied at the 60Hz frequency. Answers must be in mH, correct up-to two decimal places. Make sure your answers make physical sense.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A three-phase, 60-Hz, 4-pole, 440-V (line-line, rms) induction-motor drive has a full-load (rated) speed of 1746...
A three-phase, 60-Hz, 4-pole, 440-V (line-line, rms) induction-motor drive has a full-load (rated) speed of 1746 rpm. The rated torque is 40 Nm. Keeping the air gap flux-density peak constant at its rated value. The frequency and voltage of the motor from above are adjusted such that the fan speed is changed to 600 rpm. The motor should be operating at 3% slip and rated Bm. What is the motor efficiency?
A 3-phase 50Hz 2-pole 440V (L-L rms) induction motor drive has a rated speed of 2955...
A 3-phase 50Hz 2-pole 440V (L-L rms) induction motor drive has a rated speed of 2955 rpm and rated torque of 35 Nm. This motor drives a load with a torque characteristic that increases linearly with speed such that it equals the load torque at the rated speed. It draws a current of 3.0 A(rms) per phase at the rated voltage at a power factor of 0.81 (lagging). The stator resistance Rs = {r_s} ohms. At the rated operating speed,...
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These...
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These are the default values of the "Asynchronous Machine" model in MATLAB Simulink. r1=0.5968 Ω; r2=0.6258 Ω; L1=0.0003495 H; L2=0.005473 H; Lm=0.0354 H; Stator line voltage = 400 V rms. The motor for rotor speeds nm= 0 to 1500 rpm. X1= 0.1097 ohm, X2= 1.719 ohm , Xm= 11.12 ohm, RTH = 0.5853 , XTH = 0.1395 and VTH = 230.82 V. Suppose the motor...
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These...
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These are the default values of the “Asynchronous Machine” model in MATLAB Simulink. r1=0.5968 ?; r2=0.6258 ?; L1=0.0003495 H; L2=0.005473 H; Lm=0.0354 H; Stator line voltage = 400 V rms. The motor for rotor speeds nm= 0 to 1500 rpm. X1= 0.1097 ohm, X2= 1.719 ohm , Xm= 11.12 ohm, RTH = 0.5853 , XTH = 0.1395 and VTH = 230.82 V. Suppose the motor...