Question

Calculate full load torque developed by an 8 pole, 50 Hz, 3 phase IM Motor operating...

Calculate full load torque developed by an 8 pole, 50 Hz, 3 phase IM Motor operating with 4 % slip on full load. Motor develops Max. Torque at a speed of 700rpm. The rotor resistance of motor is 0.5 ohm per phase. Standstill rotor emf is 120v per phase.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Problem 4: A 6 pole, three phase, 50 Hz induction motor has rotor resistance of 0.075...
Problem 4: A 6 pole, three phase, 50 Hz induction motor has rotor resistance of 0.075 ohm and standstill reactance of 0.125 ohm per phase. On full load it is running at a speed of 240 r.p.m. The rotor induced e.m.f per phase at standstill is observed to be 16 V. Calculate; Starting torque, Full load torque Maximum torque Speed at max torque Problem 5: The following data refers to a 10-pole, 200 V, 50 Hz, 3 phase induction motor?
Problem 1: A 800 V, 4 pole, 3 phase, and 50 Hz star connected induction motor...
Problem 1: A 800 V, 4 pole, 3 phase, and 50 Hz star connected induction motor has a rotor resistance and reactance per phase equal to 0.02 ohm and 0.2 ohm respectively. Determine 1) starting torque 2) slip at which maximum torque will occur 3) speed at which maximum torque will occur 4) Maximum torque 5) full load torque if full load slip is 8%. Assume ratio of stator to rotor turns as 8.
A 37.3 kW, 3 phase, 4 pole, 50 Hz, induction motor has a full load efficiency...
A 37.3 kW, 3 phase, 4 pole, 50 Hz, induction motor has a full load efficiency of 85%. The friction and windage losses are one third of the no load losses and the copper loss equals the iron loss at full load. Find the full load speed. Stator resistance may be neglected. [Answer: 1401.3 rpm]
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These...
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These are the default values of the "Asynchronous Machine" model in MATLAB Simulink. r1=0.5968 Ω; r2=0.6258 Ω; L1=0.0003495 H; L2=0.005473 H; Lm=0.0354 H; Stator line voltage = 400 V rms. The motor for rotor speeds nm= 0 to 1500 rpm. X1= 0.1097 ohm, X2= 1.719 ohm , Xm= 11.12 ohm, RTH = 0.5853 , XTH = 0.1395 and VTH = 230.82 V. Suppose the motor...
Problem 3: A 3-phase, 4 pole, 50 Hz induction motor is supplied by 200 V supply....
Problem 3: A 3-phase, 4 pole, 50 Hz induction motor is supplied by 200 V supply. Its full load slip is 2%. At full load, stator copper losses are same as rotor copper losses. Stator iron losses are 50% more than stator copper losses. Mechanical losses are one third of no load losses. Full load output is 50 H.P. Calculate the efficiency on full load.
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These...
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These are the default values of the “Asynchronous Machine” model in MATLAB Simulink. r1=0.5968 ?; r2=0.6258 ?; L1=0.0003495 H; L2=0.005473 H; Lm=0.0354 H; Stator line voltage = 400 V rms. The motor for rotor speeds nm= 0 to 1500 rpm. X1= 0.1097 ohm, X2= 1.719 ohm , Xm= 11.12 ohm, RTH = 0.5853 , XTH = 0.1395 and VTH = 230.82 V. Suppose the motor...
Q1. A 440 V, 60 Hz, six-pole, 3 phase induction motor is taking 50 kVA at...
Q1. A 440 V, 60 Hz, six-pole, 3 phase induction motor is taking 50 kVA at 0.8 power factor and is running at a slip of 2.5 percent. The stator copper losses are 0.5 kW and rotational losses are 2.5 kW. i) The rotor copper losses ii) The shaft hp iii) The efficiency iv) The shaft torque
A three-phase, 60-Hz, 4-pole, 440-V (line-line, rms) induction-motor drive has a full-load (rated) speed of 1746...
A three-phase, 60-Hz, 4-pole, 440-V (line-line, rms) induction-motor drive has a full-load (rated) speed of 1746 rpm. The rated torque is 40 Nm. Keeping the air gap flux-density peak constant at its rated value. The frequency and voltage of the motor from above are adjusted such that the fan speed is changed to 600 rpm. The motor should be operating at 3% slip and rated Bm. What is the motor efficiency?
A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full...
A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. What is the output power of this motor in kW? If friction and windage loss is 350 watts, what is the gross mechanical output at full load? What is the gross torque of this motor at full load? What is the rotor cupper loss at full load? If the efficiency of this motor is 90% at full load what is...
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a...
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. a)-What is the synchronous speed of this motor? b)-What is the shaft speed of this motor at full load? c)-What is the frequency of rotor current at full load? d)-What is the shaft torque of this motor at full load? e)-If the efficiency of this motor is 90% at full load what is the input power f)-If the efficiency...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.