can I get short circuit and open circuit tests data for synch generator as excel file(not plot). and spicify the gen ratings.
Machine Raigs are as follows-
Winding type - Y (Star) connection
Rated Power (S) = 150kVA
Rated terminal line-to-line r.m.s. voltage (Vt) = 220V
frequency (f) =50Hz
Number of Poles(P) = 6
Open circuit test data-
OPEN CIRCUIT TEST DATA | |
Field current | Open circuit Voltage (Per Phase) |
0.2 | 30 |
0.4 | 60 |
0.6 | 85 |
0.8 | 114 |
1 | 145 |
1.2 | 170 |
1.4 | 196 |
1.6 | 230 |
1.8 | 262 |
2 | 274 |
2.2 | 301 |
2.4 | 307 |
Short Circuit Test-
SHORT CIRCUIT TEST DATA | |
Field current | Short Circit Current (A) |
0.2 | 6.4 |
0.4 | 13 |
0.6 | 18.5 |
0.8 | 25.4 |
1 | 32.1 |
1.2 | 40 |
1.4 | 45.9 |
1.6 | 46 |
1.8 | 59 |
Get Answers For Free