Question

Determine and tabulate the diode ratings of the following three-phase rectifiers: zigzag, fork and double-star for...

Determine and tabulate the diode ratings of the following three-phase rectifiers: zigzag, fork and double-star for a chemical load of 50 V 1000 A.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A three-phase six-step inverter delivers power to a resistive load from a 450 V dc source....
A three-phase six-step inverter delivers power to a resistive load from a 450 V dc source. For a star-connected load of 10 ? per phase, determine: (i) rms value of load current (ii) rms value of IGBT current (iii) Load power.
A 70.7 (line voltage) three phase star connected source is connected to a balanced delta load...
A 70.7 (line voltage) three phase star connected source is connected to a balanced delta load having impedance of 14.14 + j14.14 ohms for each phase. Assuming abc sequence, find a) Line currents b) Total 3 phase power
A 230 volt, 60 Hz, 4 pole star connected, three phase induction motor operates at a...
A 230 volt, 60 Hz, 4 pole star connected, three phase induction motor operates at a full load speed of 1710 rpm. The power developed at this speed is 2 horse power. If the supply voltage fluctuates ±10%, determine the torque range of the motor.
A six-phase star rectifier has a purely resistive load of R = 10ohms. The peak supply...
A six-phase star rectifier has a purely resistive load of R = 10ohms. The peak supply voltage Vm = 170 V, and the supply frequency f = 60 Hz. Determine the average output voltage of the rectifier if the source inductance is negligeble
4) A three-phase synchronous motor of 4000 hp nominal, 13,200 V, 60 Hz, 2 poles, connected...
4) A three-phase synchronous motor of 4000 hp nominal, 13,200 V, 60 Hz, 2 poles, connected in star, operating at 0.84 of power factor in advance, has an efficiency of 96.5%. The synchronous reactance per phase is 49.33 Ω: • Draw the phasor diagram on the grid sheet • Determine the loading angle • Determine the load torque
A three phase, 200 kW, 2300 V, 50 Hz star (wye) connected non-salient rotor synchronous motor...
A three phase, 200 kW, 2300 V, 50 Hz star (wye) connected non-salient rotor synchronous motor has a synchronous reactance of 11 Ohms per phase. When it draws 175 kW the power angle is 10 electrical degrees. Neglect the ohmic losses. a. Determine the excitation voltage per phase. b. Calculate the supply line current. c. Determine the supply power factor. d. Draw the phasor diagram. e. By what percentage should the field current be changed to minimize the line current.
A three-phase, 50 Hz, alternator has an inertia constant of 4pu/s. Calculate the following: i) Angular...
A three-phase, 50 Hz, alternator has an inertia constant of 4pu/s. Calculate the following: i) Angular speed ii) Accelerating power if the mechanical power is 1pu and electrical power is also 1pu. iii)Accelerating power when a short circuit fault occurs at the generator terminals iv) Angular momentum v) Load angle 6 cycles after the occurrence of the fault if the initial load angle is 18⁰.
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is...
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is rated at 1000 kVA and has a step-down ratio of 8:1. The bank supplies a balance load having a power factor of 0.8 lag with a load current of 70 A. Assume ideal transformer, determine. The primary line and phase voltages The secondary line and phase voltages The secondary line and phase currents The apparent and active power at the load Total kVA capacity...
2. Three phase loads are in Y connection. Each load has a 20 Ω resistor and...
2. Three phase loads are in Y connection. Each load has a 20 Ω resistor and a 12 Ω reactor series. If the line voltage is 440 V, calculate the following: a. The total active power, reactive power, and apparent power supplied to the three-phase load. b. The voltage across each resistor.
Three star-connected coils are drawing line current of 30A from a three phase supply. Also, total...
Three star-connected coils are drawing line current of 30A from a three phase supply. Also, total apparent and active powers of 25kVA and 11 kW respectively are absorbed by the coils. By assuming that the each coil is characterized by equal impedance, determine: i. the line and phase voltages ii. the total reactive power (1 mark) iii. the impedance of each coil. c) If the coils in Q2(b) are suddenly reconfigured into delta connection, calculate the new line currents and...