(a) Draw a graph of the output emf from a chromel-alumel thermocouple (type K) and from a copper-constantan thermocouple (type T) over the temperature range from 0 C to 550 C by reading appropriate data from a thermocouple table. Assume that the reference junction of the thermocouple is maintained at 0 C in an ice bath. Draw the graphs for both thermocouples on the same piece of graph paper.
(b) Calculate the measurement sensitivity of each thermocouple over the temperature range from 250 C to 400 C.
(a).
K-Type Thermocouple:
T-type Thermocouple: (range is limited up to 400o C)
T-V Plot:
(b).
K-Type:
Output voltage at 250o C = 10.153 mV
Output voltage at 400o C = 16.397 mV
Sesativity:
T-Type:
Output voltage at 250o C = 12.013 mV
Output voltage at 400o C = 20.872 mV
Sesativity:
Get Answers For Free