Question

A type of transformer assembly for use with load tap changers is the A. iron-core reactor.....

A type of transformer assembly for use with load tap changers is the A. iron-core reactor.. B. constant-current transformer. C. air-insulated reactor. D. oil-insulated reactor.

Homework Answers

Answer #1

Firstly there are two types of load tap changers 1)on load tap changers(oltc) and

2) off load tap changers (oftc)

Noe comes to on load tap changers we mostly and generally use oil insulated one and in off load tap changers we go with the air insulated reactors .Here in the given questio they didn't mention about what is the type of transformer it is either off load or on load ,but now comes to modern life now all transformers used are on load tap changers so we can choose the option D which is oil insulated reactor

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
  A 2000-kva transformer has a no-load loss of 6 kw and a total load loss of...
  A 2000-kva transformer has a no-load loss of 6 kw and a total load loss of 16 kw, at full load, and at 100% power factor. The efficiency of the transformer at one-half this load is      A. 99.01%. B. 99.16%. C. 99.75% D. 99.63%.
Magnetization. Consider a long solenoid with a core that is an iron alloy.  Suppose that the diameter...
Magnetization. Consider a long solenoid with a core that is an iron alloy.  Suppose that the diameter of the solenoid is 2 cm and the length of the solenoid is 20 cm.  The number of turns on the solenoid is 200.  The current is increased until the core is magnetized to saturation at about I= 2 A and the saturated magnetic field is 1.5 T. (a) What is the magnetic field intensity at the center of the solenoid and the applied magnetic field,...
At 25 C the total load loss of a transformer is 18 kw and the I2R...
At 25 C the total load loss of a transformer is 18 kw and the I2R loss is 12 kw. If the load remains the same, the total load loss at 75 C is      A. 26.51 kw. B. 14.32 kw. C. 19.35 kw. D. 35.84 kw.
A powdered iron (Bsat = 1 T) toroid core has µ = 25µ0 (µ0 = 4π...
A powdered iron (Bsat = 1 T) toroid core has µ = 25µ0 (µ0 = 4π × 10-7 H/m). The outside diameter is 30 mm, the inside diameter is 15 mm, and the thickness is 10 mm. a) What energy can be stored in an inductor built on this core? b) In a certain dc-dc converter application, the maximum volt · second value is 50 µV · s. Choose a number of turns to allow this core to meet this...
A transformer has 500. primary turns and 10.0 secondary turns. (a) If Vp is 120.V(rms), what...
A transformer has 500. primary turns and 10.0 secondary turns. (a) If Vp is 120.V(rms), what is Vs? If the secondary now has a resistive load of 10.0Ω, what is the current in the (b) secondary and (c) primary? (Hints: Input power equals the output power. Express power in terms of voltage and current, then use Faraday’s Law to relate voltage to number of turns and change of flux. If the primary and the secondary are connected via a closed...
30. A 480/240 Volt, Step-down transformer with a primary current of 200 amperes will have an...
30. A 480/240 Volt, Step-down transformer with a primary current of 200 amperes will have an approximate secondary current of ______ amperes. A. 100 B. 200 C. 300 D. 400 31. The inverter output of a stand-alone photovoltaic system shall be permitted to supply 120 volts to a single-phase, 3-wire 120/240 volt service where there are no _____ on the system. A. Motors connected B. Transformers connected C. Multi-wire branch circuits D. Appliance branch circuits 32. When a combination transformer...
Problem 2. A three phase transformer rated at 5 MVA, 115/13.2 kV has a per phase...
Problem 2. A three phase transformer rated at 5 MVA, 115/13.2 kV has a per phase series impedance of 0.007 + j0.075 per unit (shunt parameters are ignored). The low voltage side is connected to a short distribution line which modeled by a series per phase impedance of 0.02 +j0.1 per unit on the base of 10 MVA. The line supplies a balanced three phase constant impedance load at 4 MVA, 13.2 kV with power factor of 0.85 lagging •...
Use MATLAB: A three-phase Y-A transformer is rated 225-kV:24-kV, 400 MVA and has a series reactance...
Use MATLAB: A three-phase Y-A transformer is rated 225-kV:24-kV, 400 MVA and has a series reactance of 6.08 Ohms as referred to its high-voltage terminals. The transformer is supplying a load of 375 MVA, with 0.89 power factor lagging at a voltage of 24 kV (line-to-line) on its low-voltage side. It is supplied from a feeder whose impedance is 0.17 + j 2.2 Ohms connected to its high-voltage terminals. The total load in the system remains constant at 375 MVA....
The transformer on a utility pole steps the voltage down from 10000 V to 220 V...
The transformer on a utility pole steps the voltage down from 10000 V to 220 V for use in a college science building. During the day, the transformer delivers electric energy at the rate of 15.0 kW a) Assuming the transformer to be ideal, during that time, what are the primary and secondary currents in the transformer? b) If the transformer is only 85 % efficient (but still delivers electric power at 15.0 kW ), how does its input current...
What is the best approach to isolate a small load sensitive to harmonics from a very...
What is the best approach to isolate a small load sensitive to harmonics from a very large load, which produces high harmonic currents? A. Provide a separate return for each phase of the high harmonic generating load and increase the size of this load’s phase supplies B. Increase the size of the neutral conductors to minimise the effect of the harmonics C. Use a ferro-resonant transformer for the sensitive load D. Shorten the distance between the service panel and the...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT