Question

At 25 C the total load loss of a transformer is 18 kw and the I2R...

At 25 C the total load loss of a transformer is 18 kw and the I2R loss is 12 kw. If the load remains the same, the total load loss at 75 C is
    
A. 26.51 kw.
B. 14.32 kw.
C. 19.35 kw.
D. 35.84 kw.

Homework Answers

Answer #1

this is approximated to 19.35.bcz these what I taken from stranded sheet of transformer losses calculation. All the best

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
  A 2000-kva transformer has a no-load loss of 6 kw and a total load loss of...
  A 2000-kva transformer has a no-load loss of 6 kw and a total load loss of 16 kw, at full load, and at 100% power factor. The efficiency of the transformer at one-half this load is      A. 99.01%. B. 99.16%. C. 99.75% D. 99.63%.
A single phase transformer rated at 3000 KVA, 69kV, 60 Hz has a total internal impedance...
A single phase transformer rated at 3000 KVA, 69kV, 60 Hz has a total internal impedance Zp of 127ohm, referred to the primary side. Calculate: a) primary and secondary currents b) voltage regulation from no load to full load for 2000 kW resistive load, knowing that the primary voltage supply is fixed at 69 kV. c) primary and secondary currents if the secondary is accidentally short circuited.
A type of transformer assembly for use with load tap changers is the A. iron-core reactor.....
A type of transformer assembly for use with load tap changers is the A. iron-core reactor.. B. constant-current transformer. C. air-insulated reactor. D. oil-insulated reactor.
30. A 480/240 Volt, Step-down transformer with a primary current of 200 amperes will have an...
30. A 480/240 Volt, Step-down transformer with a primary current of 200 amperes will have an approximate secondary current of ______ amperes. A. 100 B. 200 C. 300 D. 400 31. The inverter output of a stand-alone photovoltaic system shall be permitted to supply 120 volts to a single-phase, 3-wire 120/240 volt service where there are no _____ on the system. A. Motors connected B. Transformers connected C. Multi-wire branch circuits D. Appliance branch circuits 32. When a combination transformer...
Seven) An ideal transformer has 25 turns on the input and 400 turns on the output....
Seven) An ideal transformer has 25 turns on the input and 400 turns on the output. There is an input voltage of 120V and an input current of 0.200A. a. What is the power input? b. What is the power output? c. What is the voltage output? d. What is the current output? e. Is this a “step up” transformer or a “step down” transformer?
Plate values ​​of a three-phase transformer are given below: 1600 kVA, 15 kV / 400 V,...
Plate values ​​of a three-phase transformer are given below: 1600 kVA, 15 kV / 400 V, 50 Hz, io = 1.2%; ukN = 6%, idle losses 2450 W, rated copper losses of power 14500 W; Dy5. a) Calculate primary and secondary line and phase currents. b) Secondary at 75% load in power factor with 0.85 inductance and 0.85 capacity calculate the voltage separately. Compare and interpret the results. capacity at what time of day can the upload be seen? To...
Plate values ​​of a three-phase transformer are given below: 1600 kVA, 15 kV / 400 V,...
Plate values ​​of a three-phase transformer are given below: 1600 kVA, 15 kV / 400 V, 50 Hz, io = 1.2%; ukN = 6%, idle losses 2450 W, rated copper losses of power 14500 W; Dy5. a) Calculate primary and secondary line and phase currents. b) Secondary at 75% load in power factor with 0.85 inductance and 0.85 capacity calculate the voltage separately. Compare and interpret the results. capacity at what time of day can the upload be seen? To...
A CI is desired for the true average stray-load loss ? (watts) for a certain type...
A CI is desired for the true average stray-load loss ? (watts) for a certain type of induction motor when the line current is held at 10 amps for a speed of 1500 rpm. Assume that stray-load loss is normally distributed with ? = 2.9. (Round your answers to two decimal places.) (a) Compute a 95% CI for ? when n = 25 and x = 57.2. , watts (b) Compute a 95% CI for ? when n = 100...
Viral Load suppress           ed Viral load not suppressed Total In continuous care 200   a 100 b...
Viral Load suppress           ed Viral load not suppressed Total In continuous care 200   a 100 b 300 Not in continuous care 150    c 350   d 500 Total 350 450 800 Question 1 The measure of association to calculate ?my answer (positive association) Question 2 calculate your work and round to the 100th decimal my calculation (a*d)/(c*b) =1.428
A CI is desired for the true average stray-load loss μ (watts) for a certain type...
A CI is desired for the true average stray-load loss μ (watts) for a certain type of induction motor when the line current is held at 10 amps for a speed of 1500 rpm. Assume that stray-load loss is normally distributed with σ = 3.3. (Round your answers to two decimal places.) (a) Compute a 95% CI for μ when n = 25 and x = 56.0. . watts (b) Compute a 95% CI for μ when n = 100...