A capacitive reactance of -j45 ohms is needed. Design a transmission line stub to produce this reactance using a 50 ohm transmission line. Use a minimum length of line. Indicate the line's length in cm at 1GHz and how it is terminated.
Please write neat and show your work
Answer :- The normalized reactance value = -j45/50 = -j0.9 . Drawing this on smith chart as point A, as shown below-