Question

A load draws 5 kVAR at a power factor of 0.86 (leading) from a 220-V rms...

A load draws 5 kVAR at a power factor of 0.86 (leading) from a 220-V rms source. Calculate the peak current and the apparent power supplied to the load.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Two AC loads connected in parallel draw power from a 60 Hz, 120-Vrms source. Load 1...
Two AC loads connected in parallel draw power from a 60 Hz, 120-Vrms source. Load 1 draws 350 W at a lagging power factor of 0.7. Load 2 draws 500 VA at a leading power factor of 0.5. a. (5) Calculate the effective (rms magnitude) current drawn by load 1. b. (10) Calculate the impedance of Load 1. c. (5) Calculate the total complex power drawn by both loads combined. d. (5) Determine the PF of the combined load. Specify...
A motor draws 12A rms from 210 V rms, a 60 hz ac source at 0.85...
A motor draws 12A rms from 210 V rms, a 60 hz ac source at 0.85 pf lagging. If a capacitor is connected to make the power factor unity, the approximate capacitance of the capacitor will be:
1. A single phase circuit has a load of 500kVa at a power factor of 0.707...
1. A single phase circuit has a load of 500kVa at a power factor of 0.707 lagging. Calculate the kVA of the capacitors needed to improve the power factor to unity 3. When connected to a 120-v(rms), 60Hz power line, a load absorbes 4 kw at a lagging power factor of 0.8. Find the capacitance necessary to raise the pf to 0.9 4. A three phase motor draws 20kva at 0.707 power factor lagging from a 208V source. Determine the...
A full-wave rectifier has a 120 V rms, 60 Hz ac source. The load is a...
A full-wave rectifier has a 120 V rms, 60 Hz ac source. The load is a series inductance, resistance and dc voltage source, with L = 100 mH, R = 10 Ω, and Vdc = 50 V. a). Determine an expression for load current. b). Determine the power absorbed by the dc voltage source. c). Determine the power absorbed by the resistance. d). Determine the power factor of the source.
Three loads are connected in parallel across a 1500 Vrms - 60 hz. Load 1 absorbs...
Three loads are connected in parallel across a 1500 Vrms - 60 hz. Load 1 absorbs 23 kW and 14 kVAr capacitive. Load 2 absorbs 70 kVA with power factor 0.7 lagging. Load 3 absorbs 22kW with power factor = 1. Find: a) Complex impedance, seen from power source b) Power Factor of the setup and module of Rms current supplied by the source c) Complex impedance of Load 2 d) Value of capacitor to be connected to the combination...
A single-phase load consumes 10kW at 0.9 power factor, power factor lagging at 220V.What is the...
A single-phase load consumes 10kW at 0.9 power factor, power factor lagging at 220V.What is the magnitude and phase angle of current drawn from the source? If another single-phase load rated at 10kW and 0.8 leading power factor is connected in parallel to the sources, what is the magnitude of the current drawn? What is the current drawn from Source? Give your answer in polar form.
A three-phase six-step inverter delivers power to a resistive load from a 450 V dc source....
A three-phase six-step inverter delivers power to a resistive load from a 450 V dc source. For a star-connected load of 10 ? per phase, determine: (i) rms value of load current (ii) rms value of IGBT current (iii) Load power.
The 400 V, 50 kVA, 0.8 power factor leading delta connected synchronous motor has synchronous reactance...
The 400 V, 50 kVA, 0.8 power factor leading delta connected synchronous motor has synchronous reactance of 3-ohm, resistance neglected. It is supplying a 12-kW load with initial power factor of 0.86 lagging. The windage and friction losses are 2.0 kW and the core losses are 1.5 kW. Determine (a) the motor efficiency; the line current; armature current; and excitation voltage. (b) If the flux of the motor is increased by 20 percent determine the excitation voltage; armature current; and...
Two industrial loads each require 250∠0 V (rms) at 60Hz. Load 1 absorbs 8kW at 0.8...
Two industrial loads each require 250∠0 V (rms) at 60Hz. Load 1 absorbs 8kW at 0.8 leading; load 2 absorbs 20kVa at 0.6 lagging l. The line that transmits the power from the source to the load has an impedance of (0.05 + j0.5) Ohm a. Sketch the circuit b. find complex power for the line and the load c. Power (complex) supply by the source (proof the sums of all power equal to zero)
THESE ARE QUESTION FROM THE TOPIC POWER FACTOR IMPROVEMENT FROM THE SUBJECT POWER SYSTEM FUNDAMENTALS PLEASE...
THESE ARE QUESTION FROM THE TOPIC POWER FACTOR IMPROVEMENT FROM THE SUBJECT POWER SYSTEM FUNDAMENTALS PLEASE DO THE QUESTIONS STEP BY STEP AND IN NEAT HAND WRITTING THE ANSWERS ARE GIVEN WITH THE QUESTIONS 1) . A station supplies 250 kVA at a lagging power factor of 0·8. A synchronous motor is connected in parallel with the load. If the combined load is 250 kW with a lagging p.f. of 0.9, determine : (i) the leading kVAR taken by the...