A motor is needed to drive a load requiring a torque of 3 kgf-cm. The motor...

A motor is needed to drive a load requiring a torque of 3 kgf-cm. The motor that is readily available has a stall torque of 23 kgf-cm and a no-load speed of 4500 rpm. At what speed would you estimate that this motor would drive the load?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A PMDC motor has a stall torque of 0.1N-m and draws 2 amps at 12V at...
A PMDC motor has a stall torque of 0.1N-m and draws 2 amps at 12V at stall. What is the no load speed in RPM when 12 V is applied?
you are given a motor operated by a 9V battery. The stall torque for this motor...
you are given a motor operated by a 9V battery. The stall torque for this motor is  Ts = 0.04 N-m, and its no-load speed, wnl = 2200  rpm. You are given a 10-tooth gear, a 20-tooth gear, and a bunch of axles (shafts). Draw below how will you connect the gears and shafts so that output shaft has a higher torque than the motor shaft. Label in your diagram, which gear is the input (driver), and which is the output (driven).   ...
A 3-phase 50Hz 2-pole 440V (L-L rms) induction motor drive has a rated speed of 2955...
A 3-phase 50Hz 2-pole 440V (L-L rms) induction motor drive has a rated speed of 2955 rpm and rated torque of 35 Nm. This motor drives a load with a torque characteristic that increases linearly with speed such that it equals the load torque at the rated speed. It draws a current of 3.0 A(rms) per phase at the rated voltage at a power factor of 0.81 (lagging). The stator resistance Rs = {r_s} ohms. At the rated operating speed,...
A three-phase, 60-Hz, 4-pole, 440-V (line-line, rms) induction-motor drive has a full-load (rated) speed of 1746...
A three-phase, 60-Hz, 4-pole, 440-V (line-line, rms) induction-motor drive has a full-load (rated) speed of 1746 rpm. The rated torque is 40 Nm. Keeping the air gap flux-density peak constant at its rated value. The frequency and voltage of the motor from above are adjusted such that the fan speed is changed to 600 rpm. The motor should be operating at 3% slip and rated Bm. What is the motor efficiency?
Electric Drive Problem 1) Why does steady state rotor speed decrease with load torque for series...
Electric Drive Problem 1) Why does steady state rotor speed decrease with load torque for series motor and remains nearly constant for shunt and separately excited motor has ? What effect does field current have on rotor speed?
Calculate full load torque developed by an 8 pole, 50 Hz, 3 phase IM Motor operating...
Calculate full load torque developed by an 8 pole, 50 Hz, 3 phase IM Motor operating with 4 % slip on full load. Motor develops Max. Torque at a speed of 700rpm. The rotor resistance of motor is 0.5 ohm per phase. Standstill rotor emf is 120v per phase.
A 200 V DC, 1,800 RPM shunt connected motor has an armature resistance of 0.4 ohm...
A 200 V DC, 1,800 RPM shunt connected motor has an armature resistance of 0.4 ohm and a brush resistance of 0.4 ohm; brush voltage drop of 6.0 V, independent of load. The resistance of the shunt field is 230 ohm. The full load rated line current is 40 A. When the motor is operated at no load the line current is 5 A and the speed is 1750 RPM. Calculate speed at rated load Calculate speed at .3 rated...
A 230 V, 250 rpm, 100 A separately excited dc motor has an armature resistance of...
A 230 V, 250 rpm, 100 A separately excited dc motor has an armature resistance of 0.5 Ω. The motor is connected to 230 V dc supply and rated dc voltage is applied the field winding. It is driving a load whose torque-speed characteristic is given by TL = 500 − 10ω where ω is the speed in rad/sec and TL is the load torque in N-m. Find (a) the steady state speed at which the motor will drive the...
Why does steady state rotor speed decrease with load torque for series motor and remain constant...
Why does steady state rotor speed decrease with load torque for series motor and remain constant for shunt and separately excited motors? What effect of field current have on motor speed?
The full-load armature current of a 5 hp, 150 V shunt dc motor is 30 A....
The full-load armature current of a 5 hp, 150 V shunt dc motor is 30 A. The field (shunt) resistance and the armature resistance of the motor are ????F = 125 ? and ???????? = 0.15, respectively. At a random speed of 1800 rpm magnetization curve of the motor has measured and is shown in the table below. ????0 (V) armature voltage 10 90 110 140 170 185 ???????? (A) field (shunt) current 0 0.82 1 1.2 1.7 2.88 Calculate...