Question

The capacitance of a 3 core cable belted type are measured and found as follows: (i)...

The capacitance of a 3 core cable belted type are measured and found as follows:
(i) the capacitance between 3 cores connected together and the sheath is 8 uF.
(ii) the capacitance between one core conductor and the other two conductors connected together to the sheath is 5 uF.
Draw the measurement configuration and the equivalent circuit for both cases and calculate:
a) the capacitance to the neutral and the capacitance between any two conductors.
b) the charging current and the total charging kVA when the cable is connected to a 11 kV,50 Hz, 3 phase supply.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 132 KV, 50 HZ, 3 phase, 3 core metal sheathed cable gave the following resutls...
A 132 KV, 50 HZ, 3 phase, 3 core metal sheathed cable gave the following resutls in testing for capacitance: (a) capacitance between shorted conductors and sheath is 0.8 micro farad. (b) capacitance between two conductors shorted with sheath and the third conductor is 0.6 micro farad. Draw the test arrangment in each case and determine: (i) the capacitance between any two conductors. (ii) the conductor self capacitance and the capacitance between any two shorted conductors and the third conductor....
The capacitances per Km of 3 core cable are 0.9 micro farad between the three bunched...
The capacitances per Km of 3 core cable are 0.9 micro farad between the three bunched conductor and the sheath, and 0.4 micro farad between one conductor and the other two connected to the sheath. Draw the arrangement in each case and find: a) the line to ground capacitance of a 20 Km cable length. b) charging current if the cable operates at 11 KV line voltage at 50 HZ. c) the power loss and loss angle if the power...
THESE ARE QUESTION FROM THE SUBJECT POWER SYSTEM FUNDAMENTALS AND THE TOPIC IS TRANSMISSION LINES 1)  A...
THESE ARE QUESTION FROM THE SUBJECT POWER SYSTEM FUNDAMENTALS AND THE TOPIC IS TRANSMISSION LINES 1)  A 200 km, 3-phase transmission line has its conductors placed at the corners of an equilateral triangle of 2·5 m side. The radius of each conductor is 1 cm. Calculate : (i) line to neutral capacitance of the line, (ii) charging current per phase if the line is maintained at 66 kV, 50 Hz. ANS IS [(i) 2·02 µF (ii) 24·2 A] 2)   A single...