Question

To start a three-phase motor, three switches (A, B and C) are required in such a...

To start a three-phase motor, three switches (A, B and C) are required in such a way that its operation only occurs under the following conditions: • When it is closed only B • When it is closed e closed only C • When A and B are simultaneously closed and C is not closed • When A and C are simultaneously closed and B is not closed

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A motor is controlled by 3 switches A, B and C according to the following logic:...
A motor is controlled by 3 switches A, B and C according to the following logic: • If all three switches are activated, the motor starts • If any two of the switches are activated, the motor starts and also starts on a warning light • If a single switch is activated the motor does not start but if the warning light comes on • if no switch is activated neither the motor nor the light turn on
Design a three-wire control circuit that reverses a one-phase AC motor using a Forward/ Reverse rotary...
Design a three-wire control circuit that reverses a one-phase AC motor using a Forward/ Reverse rotary switch. Include in your design two start switches and one Stop switch. Either Start switch should start the one-phase AC motor while in the forward or reverse direction. Include in your design a three-phase AC motor that will be controlled by a variable speed drive (PowerFlex40). Your circuit design should only allow the three-phase AC motor to operate (from the front keypad) when the...
A machine tool in a manufacturing cell is driven by a 3-phase a.c. motor controlled by...
A machine tool in a manufacturing cell is driven by a 3-phase a.c. motor controlled by an inverter. Before the inverter receives a RUN signal from a PLC, the following conditions must be met: (a) The workpiece is to be in its initial position in the chuck. (WPI) (b) Lubrication pressure is to be 5 bar or above. (LUB) (c) No movement is to have been detected in the cell for 1 minute. (SAFE) (d) The pre-start inverter self-test routine...
A three phase Y connected synchronous motor has negligible armature resistance and a synchronous reactance of...
A three phase Y connected synchronous motor has negligible armature resistance and a synchronous reactance of 12 ohm/phase. The motor takes 12,000kW at a line voltage of 13,200V. If the line current is adjusted so that the excitation voltage is 9000V/phase: a. What is the torque angle? b. At what power factor is the motor operating? c. What is its armature current?
Please be clear in concept and handwriting. A 20HP, three-phase, Wye-connected synchronous motor is connected to...
Please be clear in concept and handwriting. A 20HP, three-phase, Wye-connected synchronous motor is connected to a 277VAC, 60Hz power supply. At rated conditions, the motor runs at 3600 rpm and presents a 0.85 lagging power factor to the power supply. The per-phase armature reactance is 350m?. Armature resistance is negligible, as are all other sources of power loss. Considering rated conditions, a. draw a single-phase equivalent circuit showing V?, Ea and IA, with values. b. draw a phasor diagram...
A three-phase, 280 V, 60 Hz, 20 hp, 1710 r/m. Y-connected induction motor has the following...
A three-phase, 280 V, 60 Hz, 20 hp, 1710 r/m. Y-connected induction motor has the following impedances in ohms per phase referred to the stator circuit: R1=0.12 Ω.                Rˈ2=0.1 Ω X1=Xˈ2=0.25 Ω        Xm=10 Ω A total rotational loss are 400 W. The core loss is lumped in with the rotational losses. For a slip of 0.05 at the rated voltage and rated frequency. Find: a) The numbers of poles of the motor. b) The stator current. c) the power factor...
A three phase Wye-connected 460 v, 4 poles, 60 Hz wound rotor induction motor has the...
A three phase Wye-connected 460 v, 4 poles, 60 Hz wound rotor induction motor has the following parameters: R1=0.3, R2=0.15, X1=0.5, X2=0.2, Xm=14 The total friction, windage, and core loss is constant at 400 w. The motor is working at its rated voltage and drives its load at 1764 rpm. a)Calculate the input current and the input power. b)Calculate the output mechanical power and torque and motor efficiency. c)Calculate the starting current of this motor and compare it with its...
1. If the Moon sets at midnight, its phase most be     A.   full     B.  ...
1. If the Moon sets at midnight, its phase most be     A.   full     B.   gibbous     C.   1st quarter     D.   third quarter     E.   crescent 2. If the Moon rises at midnight, its phase most be     A.   full     B.   gibbous     C.   1st quarter     D.   3rd quarter     E.   crescent 3. If the Moon rises at sunset, its phase most be     A.   full     B.   new     C.   1st quarter     D.   3rd...
A 6-pole and three-phase induction motor has synchronous speed of 1125 RPM. a) Find the no-load...
A 6-pole and three-phase induction motor has synchronous speed of 1125 RPM. a) Find the no-load and full-load operating speed of motor for the cases given 1. 2.5Hz electrical frequency of rotor for no-load condition. (15p) 2. 6.3Hz electrical frequency of rotor for full-load condition. (15p) b) Find the speed regulation of motor by using parameters found above. (10p) c) Determine the electrical frequency of rotor under full-load condition so that speed regulation would be equal to 5%? (Electrical frequency...
A three-phase wye-connected (Y) synchronous generator is operating at Ea = 8.OLO° kV (lineneutral) and has...
A three-phase wye-connected (Y) synchronous generator is operating at Ea = 8.OLO° kV (lineneutral) and has synchronous reactance of X~ = 1.0 fl . The generator is connected to a threephase delta-wye connected step-down transformer that is constructed from three individual single-phase transformers. Each the single-phase transformers has rated power of 200 kVA has a turns ratio of 4:1 where the rated primary voltage of 8.0 kV and a rated secondary of 2.0 kV and a per-unit series reactance of...