1. During HFC-134a refrigerant recovery, when gauge readings
indicate pressure in an A/C system after a 5 minute pause since the
system was drawn into a vacuum, you should:
A. Repeat the recovery process
B. Wait overnight, then add refrigerant
C. Flush the system with ester oil
D. Vent the remaining refrigerant
2. Why are shut-off valves located within 12 inches from the “vehicle ends” of A/C service equipment hoses?
A. To keep out contamination
B. To reduce pressure blow-back
C. To stop venting ozone
D. To minimize venting of refrigerant
3. If an HFC-134a A/C system still has pressure after the first
refrigerant recovery process is complete (including the five-minute
pause), additional recovery necessary until the system vacuum level
remains stable for:
A.30 seconds
B. 2 minuets
C. 5 minutes
D. 10 minutes
4. Which of the following statements is correct about flushing
A/C systems?
A. Most A/C system manufacturers recommend flushing
B. A/C system flushing effectively cleans very small refrigerant
passages
C. Flushing chemicals make refrigerant cool better
D. Flushing solvents may remain in A/C systems, causing
problems
5. HFO-1234yf is classified as “A2L-mildly flammable.” This
means :
A. It smells like ammonia
B. It is highly explosive, like gasoline
C. It can ignite under certain circumstances
D. It will not ignite
1) -----(A) Repeat the recovery process until the A/C systems holds stable vacuum.
2)-----(D) To minimize venting of refrigerant
Because refrigerant is used in heat pump and refrigeration cycle. Continuous cycle of refrigeration it experiences stage advances from a fluid to a gas and back once more.
3)-----(B) 2 minutes
4)----(B) A/C system flushing effectively cleans very small refrigerant passages
because very small refrigerant contamination can cause restriction and problems for a good function of the compressor.
5)-----(C) It can ignite under certain circumstances
Because in a report of Honeywell claimed that 'HFO-1234yf is very difficult to ignite with electric spark in the range of temperature 500 0C - 900 0C. Ignition was only seen when HFO-1234yf is mixed with PAG at the temperature > 900 0C.