Question

There is a synchronous generator with a rated output of 100 MVA. At rated output, voltage...

There is a synchronous generator with a rated output of 100 MVA. At rated output, voltage 6600v, power factor 85%, efficiency 98%.

Answer the questions below...

1- Voltage per phase for Y connection

2- Output current

3- Magnitude of mechanical power input to generator in (MW)

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 125 MVA 11 kV three phase 50 Hz synchronous generator has a synchronous reactance of...
A 125 MVA 11 kV three phase 50 Hz synchronous generator has a synchronous reactance of 1.33 p.u. The generator achieves rated open circuit voltage at a field current of 325 A. The generator is connected to a network with an equivalent line-line voltage of 11 kV and an equivalent impedance of 0.17 pu on the generator base. The generator is loaded to a real power of 110 MW. a- Find the generated voltage Eaf in p.u. such that the...
A 3-phase, 1.2 MVA, Y-connected, 6.6 KV, 6-poles, 60 HZ, synchronous generator has a synchronous reactance...
A 3-phase, 1.2 MVA, Y-connected, 6.6 KV, 6-poles, 60 HZ, synchronous generator has a synchronous reactance of 30W and negligible resistance. The generator is connected to an infinite bus at 6.6 KV and 60 Hz. a)Determine the excitation voltage (Ea) when the machine is delivering rated power at o.8 PF lagging. b)The field excitation current is increased by 10% without changing the power input from the prime mover. Find the stator current (Ia), the power factor and the reactive power...
The test results of a three-phase synchronous generator with the rated voltage of 6,600V and the...
The test results of a three-phase synchronous generator with the rated voltage of 6,600V and the capacity of 50 MVA are as follows. No-load test result: When the terminal voltage was 6,600V, the field current was 1280A. Short circuit test result: The field current required to flow the rated current was 1600A. Find the rated current of this generator Find the short-circuit ratio. However, the second decimal shall be rounded off to obtain the first decimal Find the synchronous reactance....
A submarine has a 3-phase, Y-connected, 2- pole, 60Hz synchronous generator rated to deliver 1687.5 kVA...
A submarine has a 3-phase, Y-connected, 2- pole, 60Hz synchronous generator rated to deliver 1687.5 kVA at a FP = 0.8 lagging with a line voltage of 450-V. The machine stator resistance RS = 0.004 ?. The synchronous reactance is Xs=0.08 ?. The actual system load on the machine draws 900 kW at FP = 0.6 lagging. Assume that a voltage regulator has automatically adjusted the field current so that the terminal voltage is its rated value. Mechanical losses are...
A two-pole Y-connected generator rated at 13.8 kV, 20 MVA, 0.8 p.f. leading is running at...
A two-pole Y-connected generator rated at 13.8 kV, 20 MVA, 0.8 p.f. leading is running at 1800 rpm. The generator has a synchronous reac- tance of 8 Ω per phase (at 60 Hz) and a negligible armature resistance per phase. The generator is operated in parallel with an interconnected power network. Compute the following: (i) What is the torque angle of the generator at rated conditions? (ii) How many MW of power this generator can deliver?
A 100 MVA, 13.2 kV three phase generator (G) having a synchronous reactance of 10% is...
A 100 MVA, 13.2 kV three phase generator (G) having a synchronous reactance of 10% is connected to a three phase Y-Y transformer T1 which feeds a 132 kV 10 miles transmission line having an impedance per phase of 2 + j5 ?/mile. At the receiving end of the transmission line is a Y-Y step down transformer T2. Three loads are connected to the secondary side of the transformer T2. Loads are as follows: Load#1 40 MVA at 0.8 pf...
A three-phase Wye-connected synchronous generator is rated 3600 rpm, 200kVA, 480V, 60 Hz. The generator’s armature...
A three-phase Wye-connected synchronous generator is rated 3600 rpm, 200kVA, 480V, 60 Hz. The generator’s armature winding resistance is RA = 0.03Ω and the synchronous reactance XS is 0.25Ω. The rotational losses are 6kW, the core losses are 4kW, and the stray losses are 1% of the output real power. The generator is delivering 200kVA power at 0.85 pf lagging at rated voltage. Taking the phase voltage at the output as a reference, answer the following questions. How many poles...
a) A three phase transformer rated at 30 MVA 10 kV(Δ)/1 kV(Y) is supplying a load...
a) A three phase transformer rated at 30 MVA 10 kV(Δ)/1 kV(Y) is supplying a load at the low voltage side. The load absorbs 5 MVA, 0.7 power factor lagging at line to line voltage 0.9 kV. The transformer has an equivalent reactance 0.05 Ω/phase. Assuming 10 MVA and 1 kV as base value, draw the per unit diagram for the system. Find the Line to Line voltage at the primary side of the transformer. b) A three-phase synchronous generator...
A synchronous generator and motor are rated 30,000kVA, 13.2kV, and both have subtransient reactances of 20%....
A synchronous generator and motor are rated 30,000kVA, 13.2kV, and both have subtransient reactances of 20%. The line connecting them has a reactance of 10% on the base of the machine ratings. The motor is drawing 20,000kW at 0.8 power-factor leading and a terminal voltage of 12.8kV when a symmetrical three phase fault occurs at the generator terminals. Find A synchronous generator and motor are rated 30,000kVA, 13.2kV, and both have subtransient reactances of 20%. The line connecting them has...
A 3- phase, 2 pole Y-connected synchronous machines has a line-line voltage of 6,000V in 60Hz...
A 3- phase, 2 pole Y-connected synchronous machines has a line-line voltage of 6,000V in 60Hz power line, has an armature reactance of 2ohms/ phase and negligible armature resistance. Compute the following A) In case of generating action if the line current is 385 A at a leading power factor of 0.8, the armature voltage per phase is 3464V, Compute the voltage per phase and power angle. B) Draw the phasor diagram. C) If the losses in the machine is...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT
Active Questions
  • a) A 1.500 L flask is filled with a mixture of 1.20 g H2 and 8.40...
    asked 1 minute ago
  • Brooklyn Corporation manufactures DVDs. The machine that is used to make these DVDs is known to...
    asked 4 minutes ago
  • Read the articles below before your response. Workplace Pregnancy Bill Introduced Despite Opposition Pregnant Workers Fairness...
    asked 15 minutes ago
  • Assembly Language Programming Write a complete assembly program that inputs a small signed integer n, whose...
    asked 31 minutes ago
  • In an effort to promote a new product, a marketing firm asks participants to rate the...
    asked 31 minutes ago
  • Antonio White’s machine shop uses 3,500 brackets during the course of a year. These brackets are...
    asked 39 minutes ago
  • a) What is ΔGrxno (in kJ) at 2715 K for the following reaction? 2POCl3(g) → 2PCl3(g)...
    asked 51 minutes ago
  • As concrete​ cures, it gains strength. The following data represent the​ 7-day and​ 28-day strength in...
    asked 51 minutes ago
  • Interpreting the european past 102H: 2) The political system of the Roman Republic was designed specifically...
    asked 52 minutes ago
  • Urea (NH2CONH2), an important nitrogen fertilizer, is produced industrially by the following reaction: 2NH3(g)+CO2(g)?NH2CONH2(aq)+H2O(l) Given that...
    asked 54 minutes ago
  • If short circuited flow is defined as the flow that stays in the basin for less...
    asked 1 hour ago
  • Clearly sketch the graph of y=x- 2 /(x+3)^2 and label in your graph everything (intercepts, asymptotes,...
    asked 1 hour ago