Question

410 Volt, 60 Hz, 600 hp, 0.6 pf-leading, four-pole Triangle connected synchronous motor has 0.9Ω synchronous...

410 Volt, 60 Hz, 600 hp, 0.6 pf-leading, four-pole Triangle connected synchronous motor has 0.9Ω synchronous reactance. Friction; wind; core losses and armature resistance are neglected.

a) If the motor is operating under magnitude of phase current (ia) 230 Ampere and power factor of 0.6 lagging,

1. Find the input power of motor in hp (10p)

2. Find the generated voltage, EA (10p)

3. Find the torque and the maximum inducible torque in current state. (10p)

b) If EA is increased by 18% find,

1. Magnitude of new armature current (ia), (10p)

2. New power factor of motor. (10p)

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
(360) Volt, 60 Hz, 600 hp, 0.6 pf-leading, four-pole -connected synchronous motor has 0.9Ω synchronous reactance....
(360) Volt, 60 Hz, 600 hp, 0.6 pf-leading, four-pole -connected synchronous motor has 0.9Ω synchronous reactance. Friction; wind; core losses and armature resistance are neglected. a) If the motor is operating under magnitude of phase current (ia) (180) Ampere and power factor of 0.6 lagging, 1. Find the input power of motor in hp 2. Find the generated voltage, EA 3. Find the torque and the maximum inducible torque in current state. b) If EA is increased by 18% find,...
The 400 V, 50 kVA, 0.8 power factor leading delta connected synchronous motor has synchronous reactance...
The 400 V, 50 kVA, 0.8 power factor leading delta connected synchronous motor has synchronous reactance of 3-ohm, resistance neglected. It is supplying a 12-kW load with initial power factor of 0.86 lagging. The windage and friction losses are 2.0 kW and the core losses are 1.5 kW. Determine (a) the motor efficiency; the line current; armature current; and excitation voltage. (b) If the flux of the motor is increased by 20 percent determine the excitation voltage; armature current; and...
A 2300-V, 400-hp, 60-Hz, 1200rpm, Y-connected synchronous motor has a rated power factor of 0.8 leading....
A 2300-V, 400-hp, 60-Hz, 1200rpm, Y-connected synchronous motor has a rated power factor of 0.8 leading. The efficiency of the motor is 90 % at full load. The armature resistance is 0.3 Ω, and the synchronous reactance is 3.55 Ω. Answer the following questions when it is operating at full load; Question 1 What is the number of poles in this motor? 2 4 6 8 10 12 Question 2 Find the output torque in Nm.(Assume 1hp=745.7W) 1985.7 2373.6 2011.9...
a 460-V 100-hp 60-Hz 4 pole Y connected synchronous motor has a operating power factor 0.85...
a 460-V 100-hp 60-Hz 4 pole Y connected synchronous motor has a operating power factor 0.85 leading the aramature resistance is o.2 ohms and synchronous reactance is 12 ohms at full load the efficiency is 85% find the sum of mechanical loss core loss and stray loss when meachine is operating at full load
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a...
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. a)-What is the synchronous speed of this motor? b)-What is the shaft speed of this motor at full load? c)-What is the frequency of rotor current at full load? d)-What is the shaft torque of this motor at full load? e)-If the efficiency of this motor is 90% at full load what is the input power f)-If the efficiency...
Please be clear in concept and handwriting. A 20HP, three-phase, Wye-connected synchronous motor is connected to...
Please be clear in concept and handwriting. A 20HP, three-phase, Wye-connected synchronous motor is connected to a 277VAC, 60Hz power supply. At rated conditions, the motor runs at 3600 rpm and presents a 0.85 lagging power factor to the power supply. The per-phase armature reactance is 350m?. Armature resistance is negligible, as are all other sources of power loss. Considering rated conditions, a. draw a single-phase equivalent circuit showing V?, Ea and IA, with values. b. draw a phasor diagram...
A 75-kW, 440-V, 0.8-PF-leading Y-connected synchronous generator has an armature resistance of 0.22 Ω and a...
A 75-kW, 440-V, 0.8-PF-leading Y-connected synchronous generator has an armature resistance of 0.22 Ω and a synchronous reactance of 3.0 Ω. Its efficiency at full load is 89% (1 Hp=746 watt). (a) What is the line current of the generator at rated conditions? (b) What is the internal generated voltage EA of this motor at rated conditions?
3) A three-phase, nozzle, 4-pole cylindrical pole synchronous generator feeds a 400 Volt, 50Hz conversion center....
3) A three-phase, nozzle, 4-pole cylindrical pole synchronous generator feeds a 400 Volt, 50Hz conversion center. The synchronous reactance of the synchronous generator is 0.72 Ove armature resistance is neglected. The relation between the pole voltage E 'induced in the induction of the synchronous generator and the excitation current, is selected as E, = 824. In this working environment of the synchronous generator, a.) On the consumer screen, find the excitation current (U), load values, internal phase values, the moment...
A three phase Y connected synchronous motor has negligible armature resistance and a synchronous reactance of...
A three phase Y connected synchronous motor has negligible armature resistance and a synchronous reactance of 12 ohm/phase. The motor takes 12,000kW at a line voltage of 13,200V. If the line current is adjusted so that the excitation voltage is 9000V/phase: a. What is the torque angle? b. At what power factor is the motor operating? c. What is its armature current?
4) A three-phase synchronous motor of 4000 hp nominal, 13,200 V, 60 Hz, 2 poles, connected...
4) A three-phase synchronous motor of 4000 hp nominal, 13,200 V, 60 Hz, 2 poles, connected in star, operating at 0.84 of power factor in advance, has an efficiency of 96.5%. The synchronous reactance per phase is 49.33 Ω: • Draw the phasor diagram on the grid sheet • Determine the loading angle • Determine the load torque