A 2300-V, 400-hp, 60-Hz, 1200rpm, Y-connected synchronous motor has a rated power factor of 0.8 leading. The efficiency of the motor is 90 % at full load. The armature resistance is 0.3 Ω, and the synchronous reactance is 3.55 Ω. Answer the following questions when it is operating at full load;
Question 1
What is the number of poles in this motor?
2
4
6
8
10
12
Question 2
Find the output torque in Nm.(Assume 1hp=745.7W)
1985.7
2373.6
2011.9
2674.7
1453.2
2204.3
Question 3
Find the total complex power drawn by the motor.
313.60-j235.21 kVA
370.40-j277.80 kVA
266.41-j199.83 kVA
369.38-j342.67 kVA
402.40-j301.80 kVA
331.42-j248.57 kVA
Question 4
Find the armature current. (Use phase a-to-neutral voltage as the reference)
93/_25.84 A
104/_36.87 A
87/_36.87 A
112/_25.84 A
93/_-25.84 A
104/_-36.87 A
Question 5
Find the induced internal voltage EA per phase as a phasor.
1556.5/_-11.64 V
1428.3/_-9.28 V
1503.9/_-13.02 V
1601.4/_-10.26 V
1489.3/_-10.39 V
1511.3/_-7.62 V