Question

A 2300-V, 400-hp, 60-Hz, 1200rpm, Y-connected synchronous motor has a rated power factor of 0.8 leading....

A 2300-V, 400-hp, 60-Hz, 1200rpm, Y-connected synchronous motor has a rated power factor of 0.8 leading. The efficiency of the motor is 90 % at full load. The armature resistance is 0.3 Ω, and the synchronous reactance is 3.55 Ω. Answer the following questions when it is operating at full load;

Question 1

What is the number of poles in this motor?

2

4

6

8

10

12

Question 2

Find the output torque in Nm.(Assume 1hp=745.7W)

1985.7

2373.6

2011.9

2674.7

1453.2

2204.3

Question 3

Find the total complex power drawn by the motor.

313.60-j235.21 kVA

370.40-j277.80 kVA

266.41-j199.83 kVA

369.38-j342.67 kVA

402.40-j301.80 kVA

331.42-j248.57 kVA

Question 4

Find the armature current. (Use phase a-to-neutral voltage as the reference)

93/_25.84 A

104/_36.87 A

87/_36.87 A

112/_25.84 A

93/_-25.84 A

104/_-36.87 A

Question 5

Find the induced internal voltage EA per phase as a phasor.

1556.5/_-11.64 V

1428.3/_-9.28 V

1503.9/_-13.02 V

1601.4/_-10.26 V

1489.3/_-10.39 V

1511.3/_-7.62 V

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
The 400 V, 50 kVA, 0.8 power factor leading delta connected synchronous motor has synchronous reactance...
The 400 V, 50 kVA, 0.8 power factor leading delta connected synchronous motor has synchronous reactance of 3-ohm, resistance neglected. It is supplying a 12-kW load with initial power factor of 0.86 lagging. The windage and friction losses are 2.0 kW and the core losses are 1.5 kW. Determine (a) the motor efficiency; the line current; armature current; and excitation voltage. (b) If the flux of the motor is increased by 20 percent determine the excitation voltage; armature current; and...
4) A three-phase synchronous motor of 4000 hp nominal, 13,200 V, 60 Hz, 2 poles, connected...
4) A three-phase synchronous motor of 4000 hp nominal, 13,200 V, 60 Hz, 2 poles, connected in star, operating at 0.84 of power factor in advance, has an efficiency of 96.5%. The synchronous reactance per phase is 49.33 Ω: • Draw the phasor diagram on the grid sheet • Determine the loading angle • Determine the load torque
20-pole, 200 hp, 660 V, 60 Hz, Y-connected, three-phase synchronous motors are operating at no load....
20-pole, 200 hp, 660 V, 60 Hz, Y-connected, three-phase synchronous motors are operating at no load. The rotor lags 0.5 degrees to the magnetic flux of the rotor with a mechanical angle, with the induced equipment power adjusted to the same magnitude as the phase voltage applied to the armature. The synchronous reactance is 10 ohms and the armature resistance is 1 ohms. Find a) The load angle of the rotor expressed in electrical angles. b) Armature current c) Equivalent...
a 460-V 100-hp 60-Hz 4 pole Y connected synchronous motor has a operating power factor 0.85...
a 460-V 100-hp 60-Hz 4 pole Y connected synchronous motor has a operating power factor 0.85 leading the aramature resistance is o.2 ohms and synchronous reactance is 12 ohms at full load the efficiency is 85% find the sum of mechanical loss core loss and stray loss when meachine is operating at full load
(360) Volt, 60 Hz, 600 hp, 0.6 pf-leading, four-pole -connected synchronous motor has 0.9Ω synchronous reactance....
(360) Volt, 60 Hz, 600 hp, 0.6 pf-leading, four-pole -connected synchronous motor has 0.9Ω synchronous reactance. Friction; wind; core losses and armature resistance are neglected. a) If the motor is operating under magnitude of phase current (ia) (180) Ampere and power factor of 0.6 lagging, 1. Find the input power of motor in hp 2. Find the generated voltage, EA 3. Find the torque and the maximum inducible torque in current state. b) If EA is increased by 18% find,...
410 Volt, 60 Hz, 600 hp, 0.6 pf-leading, four-pole Triangle connected synchronous motor has 0.9Ω synchronous...
410 Volt, 60 Hz, 600 hp, 0.6 pf-leading, four-pole Triangle connected synchronous motor has 0.9Ω synchronous reactance. Friction; wind; core losses and armature resistance are neglected. a) If the motor is operating under magnitude of phase current (ia) 230 Ampere and power factor of 0.6 lagging, 1. Find the input power of motor in hp (10p) 2. Find the generated voltage, EA (10p) 3. Find the torque and the maximum inducible torque in current state. (10p) b) If EA is...
A 75-kW, 440-V, 0.8-PF-leading Y-connected synchronous generator has an armature resistance of 0.22 Ω and a...
A 75-kW, 440-V, 0.8-PF-leading Y-connected synchronous generator has an armature resistance of 0.22 Ω and a synchronous reactance of 3.0 Ω. Its efficiency at full load is 89% (1 Hp=746 watt). (a) What is the line current of the generator at rated conditions? (b) What is the internal generated voltage EA of this motor at rated conditions?
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a...
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. a)-What is the synchronous speed of this motor? b)-What is the shaft speed of this motor at full load? c)-What is the frequency of rotor current at full load? d)-What is the shaft torque of this motor at full load? e)-If the efficiency of this motor is 90% at full load what is the input power f)-If the efficiency...
A 100 hp, three-phase, 60Hz, 460V, four-pole, Y-connect synchronous motor is operating leading at 0.8 p.f....
A 100 hp, three-phase, 60Hz, 460V, four-pole, Y-connect synchronous motor is operating leading at 0.8 p.f. at rated conditions. Excluding field and stator losses, the efficiency is 96% and the synchronous reactance is 2.72ohm. Find a) Induced torque b) Armature current c) Internal induced electromotive force and power angle. d) Maximum load that can be driven by this electric motor. answer a) 412.2 N-m b) 121.9 A c) 535.5 V, 29.7 deg d) 153.8 kW
A three phase, 200 kW, 2300 V, 50 Hz star (wye) connected non-salient rotor synchronous motor...
A three phase, 200 kW, 2300 V, 50 Hz star (wye) connected non-salient rotor synchronous motor has a synchronous reactance of 11 Ohms per phase. When it draws 175 kW the power angle is 10 electrical degrees. Neglect the ohmic losses. a. Determine the excitation voltage per phase. b. Calculate the supply line current. c. Determine the supply power factor. d. Draw the phasor diagram. e. By what percentage should the field current be changed to minimize the line current.