QUESTION 1
The term "Slip" indicates the difference between the motor's synchronous speed and the no-load speed
True |
||
False |
1 points
QUESTION 2
Wet Bulb (WB) Temperature: is for the temperature reading form an ordinary mercury bulb thermometer or regular temperature sensor.
True |
||
False |
1 points
QUESTION 3
The refrigerant (R-134a) is the new replacement of the refrigerant (R-22) as it is less harmful to the environment.
True |
||
False |
1 points
QUESTION 4
Draft Gauge and Bourdon Gauge are used in the pressure measurement
True |
||
False |
1 points
QUESTION 5
For a large boiler, you have the choice of the following energy sources. which source will be the best with lowest point of use cost? Option1:Natural gas @ $0.4/m3, Efficiency 84%. Option2: Fuel Oil #2 @ $0.8/liter, Efficiency 86%. Option3: Electricity @ $0.095/kWh, Efficiency 96%
Natural Gas |
||
Fuel Oil#2 |
||
Electricity |
||
Both a & c |
1 points
QUESTION 6
5,000 L/s of air leaves an air handler at 10 ºC . It is delivered to a room at 18 ºC. How many kW if air conditioning capacity was lost in the ductwork?
48 kW |
||
20 kW |
||
36 kW |
||
60 kW |
1 points
QUESTION 7
Which has the greatest NPV assuming a 25 year planning horizon and MARR = 12%?
Install a $20,000 solar system that will last 25 years, and generate 38,000 kWh/year at $0.10/kWh. |
||
Install a $25,000 Ground-Source Heat pump that will last 50 years and save $3,500/year. |
||
Both options has equal NPV |
||
Not possible to be calculated |
1 points
QUESTION 8
A 20 kW electric roof top A/C unit (RTU) is 10 years old, and has a COP of 2.0 . It operates at full load for 3,000 hours a year. The electric cost is $0.10 per kWh. If this to unit to be replaced with a new 20 kW, what is the minimum value of COP for the new unit to reach an annual savings of $1,500?
3.5 |
||
4.0 |
||
4.5 |
||
Can not be determined |
1 points
QUESTION 9
kWh is a measure of …………… and kW is a measure of ……………..?
Energy, Energy |
||
Energy, Power |
||
Power, Energy |
||
Power, Power |
1 points
QUESTION 10
A 20 kW motor is presently driving a centrifugal fan at 1,480 rpm. What would the savings in kW and US $ be if the fan pulley was changed so that the new speed was 1,350 rpm? The motor efficiency is 93.5%. Assume motor is operated 3,500 hours annually and the energy cost is $ 0.10/kWh
$ 1,605 |
||
$ 1980.2 |
||
$ 1,804.4 |
||
$ 2049.7 |
1 points
QUESTION 11
For a particular month the energy consumption is 150 000 kWh and the maximum demand is 420 kVA. The applicable utility rates are €0.08c/kWh and €45/kVA. The factory produced 2050 units of product in that month. Calculate the cost intensity.
€ 15 /unit |
||
€ 15.07 /unit |
||
€ 22.3 /unit |
||
€ 30.9 /unit |
1 points
QUESTION 12
A roof top air conditioner has an EER of 14.4, what is its COP?
1.0 |
||
2.0 |
||
3.0 |
||
4.0 |
1 points
QUESTION 13
Calculate the amount of reactive power that must be supplied by capacitors to correct a power factor of 80% to 95% in a 315 kW motor at 75% load and 94% efficiency
66.9 kVAR |
||
82.5 kVAR |
||
90.4 kVAR |
||
105.8 kVAR |
1 points
QUESTION 14
A Hockey Arena has a desiccant unit installed to assist in controlling humidity and to make the ice harder. The unit will last 17 years and is projected to save $57,200 per year in HVAC and Refrigeration energy costs. If the system will cost $223,650 to be installed, what is the internal rate of return of the project?
10% |
||
12% |
||
15% |
||
25% |
1 points
QUESTION 15
Why do utilities charge a power factor charge?
The utility has to deliver more current for the same kW billed |
||
The utility has to install capacitors to compensate |
||
The utility has to install conductors to compensate |
||
All of the above |
1 points
QUESTION 16
A facility Which instrument is useful for identifying uninsulated steam lines:
Tachymeter |
||
Psychrometer |
||
Infrared Camera |
||
Bourdon Gauge |
1 points
QUESTION 17
Which instrument is used to monitor O2, CO in flue gas?
Combustion analyser |
||
Power analyser |
||
Pyrometer |
||
Fyrite |
1 points
QUESTION 18
If a 75-kW fan motor has a VSD installed that slows down the fan by 20% what is the effect on air flow rate and the kW savings?
20% CFM reduction, and 36.6 kW savings |
||
80% CFM reduction, and 51.2 kW savings |
||
20% CFM reduction, and 20 kW savings |
||
20% CFM reduction, and 37.4 kW savings |
1 points
QUESTION 19
…………. is the light energy radiated per second, and it is measured in ……………. ?
Lux , Lu/m2 |
||
Lux, Lm |
||
Luminous Fulx , Lm |
||
Luminous flux, Lu/m2 |
1 points
QUESTION 20
A new lighting system is installed to reduce energy use in a building. What data is NOT needed to verify savings for this project?
Measurement of the CO2 level in the building |
||
Measurement of light levels |
||
Measurement of the power on the lighting circuit |
||
Measurement of the lighting system operating hours |
1). False
Difference between synchronous speed and rotor speed.
2). False
3). True
4). True
Draft Gauge and Bourdon Gauge are used in the pressure measurement
9). kWh is for energy and KW is for power
15). The utility has to install capacitors to compensate.
16). Option c - Infrared camera. Explanation: Tachymeter is used to mesure speed based on time tavelled over a fixed distance. Whereas, Pshycrometer is used for measuring humidity of air
17). Combustion analyser
Hand held Flue Gas Analyser (FGA) A handheld FGA will typically measure O2 and/or CO2 and sometimes other toxic gases such as Nitric Oxide (NO) and Carbon Monoxide (CO). Various technologies are used for the gas measurement
18). Luminous Flux is the light energy radiated per second , Lm is its units.
Get Answers For Free