Question

The synchronous generator or alternator is an electrical machine that converts the mechanical power from a...

The synchronous generator or alternator is an electrical machine that converts the mechanical power from a prime mover into an AC electrical power at a particular voltage and frequency. The synchronous motor always runs at a constant speed called synchronous speed. A three phase, 8 pole, synchronous Generator is coupled to a diesel engine running at 500 rpm. It supplies an induction motor which has a full load speed of 1440 rpm. Find the percentage slip and number of poles of the induction motor

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
7-     a 3 phase induction motor haring a synchronous speed is 1600 rpm. it draws a...
7-     a 3 phase induction motor haring a synchronous speed is 1600 rpm. it draws a current of 100Kw a from a 3-phase source. The copper losses and iron losses in the stator are 6KW if the motor runs at 1500 rpm, calculate the following A- The active power transom to the rotor B- The rotor I2R losses C- The mechanical power developed. D- The mechanical power delivered to the load, knowing that the windage and friction losses are equal...
A 4- pole, 50 Hz, Y-connected, 3-phase generator has a phase voltage of 260 V ∠0°,...
A 4- pole, 50 Hz, Y-connected, 3-phase generator has a phase voltage of 260 V ∠0°, a synchronous reactance of 0.06 Ω, a stator resistance of 0.003 Ω, and Lsf= 0.02 H. The generator is directly connected to a balanced 3-phase load that draws 2 MW at a lagging 0.8 power factor. Sketch the equivalent circuit annotating all the components, currents and voltages on the diagram Calculate the 3-phase apparent power of the load in rectangular form Calculate the generator...
A three-phase, 9,375 kVA, 13.8 kV, 4-pole, 60 Hz, Y-connected synchronous generator has a synchronous reactance,...
A three-phase, 9,375 kVA, 13.8 kV, 4-pole, 60 Hz, Y-connected synchronous generator has a synchronous reactance, Xs = 17.9, and is connected to an infinite bus at rated voltage. If the rotational and electrical losses are negligivle, what is Ia, Ef, delta, theta, Tdrive, Phasor diagram, and power flow diagram (label completely with numerical values for, A) the machine as a generator; the prime-throttle is opened and If is adjusted so that the machine delivers rated kVA, 0.8 pf lagging,...
Determine the kinetic energy stored by a 300 MVA, 60 Hz, two pole synchronous generator with...
Determine the kinetic energy stored by a 300 MVA, 60 Hz, two pole synchronous generator with an inertia constant H of 5.66 MJ/MVA. Assume the machine is running steadily at synchronous speed with a shaft input of 366000 hp. The electrical power developed suddenly changes from its normal value to a value of 200 MW. a. Determine the acceleration or deceleration of the rotor. b. If the acceleration computed for the generator is constant for a period of 10 cycles,...
A three-phase wye-connected (Y) synchronous generator is operating at Ea = 8.OLO° kV (lineneutral) and has...
A three-phase wye-connected (Y) synchronous generator is operating at Ea = 8.OLO° kV (lineneutral) and has synchronous reactance of X~ = 1.0 fl . The generator is connected to a threephase delta-wye connected step-down transformer that is constructed from three individual single-phase transformers. Each the single-phase transformers has rated power of 200 kVA has a turns ratio of 4:1 where the rated primary voltage of 8.0 kV and a rated secondary of 2.0 kV and a per-unit series reactance of...