Question

A three-phase 12-mile, 50 kV (line), 60 Hz line has a resistance of 0.1, capacitance of...

A three-phase 12-mile, 50 kV (line), 60 Hz line has a resistance of 0.1, capacitance of 0.01 and inductance of 1 mH/km. The load at the receiving end of the line absorbs 10 MVA at 90 percent of rated voltage. Calculate:

  1. ABCD parameters of the line
  2. The sending-end voltage if the load power factor is 0.8 lagging.
  3. The sending-end line voltage, line current and complex power if the load has a power factor of 0.7 leading.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 250 km , three- phase , 50 Hz transmission line is delivering 25 MVA at...
A 250 km , three- phase , 50 Hz transmission line is delivering 25 MVA at 0.8 lagging power factor to a balanced load at 132 KV ( line-line) . The conductor resistance is 0.11 ohm/km . The line inductance per phase is 1.24 mH/km and the line to neutral capacitance is given as 9.4 x 10 – 9 F/km. a ) find the nominal – Л representation. b) find the sending end voltage , VS by nominal – Л...
1- A 69-kV, three-phase short transmission line is 16 km long. The line has a per...
1- A 69-kV, three-phase short transmission line is 16 km long. The line has a per phase series impedance of 0.125 + j0.4375 ohm per km. Determine the sending end voltage, voltage regulation, the sending end power, and the transmission efficiency when the line delivers a. 70 MVA, 0.8 lagging power factor at 64 kV b. 120 MW, unity power factor at 64 kV 2-three-phase, completely transposed 345-kV, 200 km line has two 795,000- cmil 26/2 ACSR conductor per bundle...
1- 30-kV, three-phase transmission line has a per phase series impedance of z = 0.05+j0.45 ohm...
1- 30-kV, three-phase transmission line has a per phase series impedance of z = 0.05+j0.45 ohm per Km and a per phase shunt admittance of y = j3.4x10-6 siemens per km. The line is 80 km long. Using the nominal π model, determine a The transmission line ABCD constants. b Find the sending end voltage and current, voltage regulation, the sending end power and the transmission efficiency when the line delivers 1. 200 MVA, 0.8 lagging power factor at 220...
Use MATLAB: A three-phase Y-A transformer is rated 225-kV:24-kV, 400 MVA and has a series reactance...
Use MATLAB: A three-phase Y-A transformer is rated 225-kV:24-kV, 400 MVA and has a series reactance of 6.08 Ohms as referred to its high-voltage terminals. The transformer is supplying a load of 375 MVA, with 0.89 power factor lagging at a voltage of 24 kV (line-to-line) on its low-voltage side. It is supplied from a feeder whose impedance is 0.17 + j 2.2 Ohms connected to its high-voltage terminals. The total load in the system remains constant at 375 MVA....
a) A three phase transformer rated at 30 MVA 10 kV(Δ)/1 kV(Y) is supplying a load...
a) A three phase transformer rated at 30 MVA 10 kV(Δ)/1 kV(Y) is supplying a load at the low voltage side. The load absorbs 5 MVA, 0.7 power factor lagging at line to line voltage 0.9 kV. The transformer has an equivalent reactance 0.05 Ω/phase. Assuming 10 MVA and 1 kV as base value, draw the per unit diagram for the system. Find the Line to Line voltage at the primary side of the transformer. b) A three-phase synchronous generator...
A 100 MVA, 13.2 kV three phase generator (G) having a synchronous reactance of 10% is...
A 100 MVA, 13.2 kV three phase generator (G) having a synchronous reactance of 10% is connected to a three phase Y-Y transformer T1 which feeds a 132 kV 10 miles transmission line having an impedance per phase of 2 + j5 ?/mile. At the receiving end of the transmission line is a Y-Y step down transformer T2. Three loads are connected to the secondary side of the transformer T2. Loads are as follows: Load#1 40 MVA at 0.8 pf...
A 33 kV, three-phase, 50 Hz line of resistance 2 Ω/ph and reactance j9 Ω/ph supplies...
A 33 kV, three-phase, 50 Hz line of resistance 2 Ω/ph and reactance j9 Ω/ph supplies a 33 kV/440 V transformer having negligible resistance and reactance of j2 Ω/ph referred to 33 kV. The transformer supplies a 440 V feeder of resistance 0.01 Ω/ph and reactance j0.007 Ω/ph. If VR, the receiving-end voltage, is 440 V, calculate VS, the sending-end voltage, when the three-phase load delivered is 440 kW at unity power factor.          
The generalized circuit constants (ABCD) of a 345 kV transmission line are given as: A =...
The generalized circuit constants (ABCD) of a 345 kV transmission line are given as: A = D = 0.82 + j0.019 B = 40 +j150 ohm C = (-1.35 + j193.3) x 10-6 S Do this problem using the per unit system. Hint: The sending end power and voltage will make good base values. a) At the sending end, the transmission line is delivering 400 MVA at 0.8 pf at the rated voltage. Find the receiving end voltage and current...
Problem 2. A three phase transformer rated at 5 MVA, 115/13.2 kV has a per phase...
Problem 2. A three phase transformer rated at 5 MVA, 115/13.2 kV has a per phase series impedance of 0.007 + j0.075 per unit (shunt parameters are ignored). The low voltage side is connected to a short distribution line which modeled by a series per phase impedance of 0.02 +j0.1 per unit on the base of 10 MVA. The line supplies a balanced three phase constant impedance load at 4 MVA, 13.2 kV with power factor of 0.85 lagging •...
A 100 km long, three phase 50 hz transmission line has resistance per phase per km...
A 100 km long, three phase 50 hz transmission line has resistance per phase per km of 0.1 ohms, reactance per phase per km of 0.5 ohms, susceptance per phase per km of 10 x 10-6 siemens. If the line supplies a load of 20 MW at 0.9 pf lagging at 66 KV at the receiving end, calculate the regulation and efficiency of the line using the following assumptions: a. nominal pi vector solution b. nominal T vector solution c....
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT