Question

Define the methodologies for power factor correction (passive, active, and synchronous phase modifier)

Define the methodologies for power factor correction (passive, active, and
synchronous phase modifier)

Homework Answers

Answer #1

Power Factor determines the efficiency of a Electrical system. power Factor is given by the formula,

  

Power Factor must be close to unity for efficiency to be high.

Low power factor occurs in unavoidable inductive loads.

This can be corrected by injecting leading current.

Some of the methodologies for power factor correction are

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 3 phase, 3.3 kV industrial plant has an overall power factor of 0.88 lagging. A...
A 3 phase, 3.3 kV industrial plant has an overall power factor of 0.88 lagging. A 200 kVA synchronous motor is added to the system and is run at zero power factor and slightly reduced rating to provide power factor correction only. The total load is then 350 kVA at unity power factor. It was then decided to run the synchronous machine at its rated kVA and use it as a source of mechanical power, what gross mechanical power would...
Q1. A 3-phase, 400 V synchronous motor having a power consumption of 50 kW is connected...
Q1. A 3-phase, 400 V synchronous motor having a power consumption of 50 kW is connected in parallel with an induction motor which takes 200 kW at a power factor of 0·8 lagging. (i) Calculate the current drawn from the mains when the power factor of the synchronous motor is unity. (ii) At what power factor should the synchronous motor operate so that the current drawn from the mains is minimum.
A three phase Y connected synchronous motor has negligible armature resistance and a synchronous reactance of...
A three phase Y connected synchronous motor has negligible armature resistance and a synchronous reactance of 12 ohm/phase. The motor takes 12,000kW at a line voltage of 13,200V. If the line current is adjusted so that the excitation voltage is 9000V/phase: a. What is the torque angle? b. At what power factor is the motor operating? c. What is its armature current?
3) A three-phase, nozzle, 4-pole cylindrical pole synchronous generator feeds a 400 Volt, 50Hz conversion center....
3) A three-phase, nozzle, 4-pole cylindrical pole synchronous generator feeds a 400 Volt, 50Hz conversion center. The synchronous reactance of the synchronous generator is 0.72 Ove armature resistance is neglected. The relation between the pole voltage E 'induced in the induction of the synchronous generator and the excitation current, is selected as E, = 824. In this working environment of the synchronous generator, a.) On the consumer screen, find the excitation current (U), load values, internal phase values, the moment...
Explain, how to control the reactive power Q (power factor) supplied by a synchronous generator? Elaborate...
Explain, how to control the reactive power Q (power factor) supplied by a synchronous generator? Elaborate using phasor diagram.
during quiet breathing, one phase of ventilation is considered passive and one active. what doez that...
during quiet breathing, one phase of ventilation is considered passive and one active. what doez that mean and why?
Write a user defined MATLAB program that performs power factor correction. The inputs to the MATLAB...
Write a user defined MATLAB program that performs power factor correction. The inputs to the MATLAB function should be voltage across the load (in Vrms, assume 0 phase), frequency Resistance of the load Inductance of the load power factor of the load target power factor The output of the function should be the size of the capacitor that one would need to place in parallel with the load to reach the target power factor. Please submit the code for the...
Hello, I was wondering what it means for the power factor of a synchronous motor to...
Hello, I was wondering what it means for the power factor of a synchronous motor to change and how changing the load changes the PF, i mean what is changing here? the load that we add to the shaft is mechanincal then how come the power factor changes?
The 400 V, 50 kVA, 0.8 power factor leading delta connected synchronous motor has synchronous reactance...
The 400 V, 50 kVA, 0.8 power factor leading delta connected synchronous motor has synchronous reactance of 3-ohm, resistance neglected. It is supplying a 12-kW load with initial power factor of 0.86 lagging. The windage and friction losses are 2.0 kW and the core losses are 1.5 kW. Determine (a) the motor efficiency; the line current; armature current; and excitation voltage. (b) If the flux of the motor is increased by 20 percent determine the excitation voltage; armature current; and...
A 42 kVA three-phase synchronous generator with line voltage 4.16 kV at a frequency of 60...
A 42 kVA three-phase synchronous generator with line voltage 4.16 kV at a frequency of 60 Hz, is connected in star configuration. The generator has a winding whose armature resistance is 0.8 Ω and a synchronous reactance of 7.4 Ω, both per phase. Determine the voltage regulation when the power factor is 0.600 lagging.
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT