Question

Q1. A 440 V, 60 Hz, six-pole, 3 phase induction motor is taking 50 kVA at...

Q1. A 440 V, 60 Hz, six-pole, 3 phase induction motor is taking 50 kVA at 0.8 power
factor and is running at a slip of 2.5 percent. The stator copper losses are 0.5 kW and
rotational losses are 2.5 kW.

i) The rotor copper losses
ii) The shaft hp
iii) The efficiency
iv) The shaft torque

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Problem 3: A 3-phase, 4 pole, 50 Hz induction motor is supplied by 200 V supply....
Problem 3: A 3-phase, 4 pole, 50 Hz induction motor is supplied by 200 V supply. Its full load slip is 2%. At full load, stator copper losses are same as rotor copper losses. Stator iron losses are 50% more than stator copper losses. Mechanical losses are one third of no load losses. Full load output is 50 H.P. Calculate the efficiency on full load.
A 100 KW (OUT PUT), 3300V, 50 Hz, 3-Phase star connected induction motor has a synchronous...
A 100 KW (OUT PUT), 3300V, 50 Hz, 3-Phase star connected induction motor has a synchronous speed of 500 rpm. The full load slip is 1.8%and full load power factor 0.85. Stator copper loss=2440W. Iron loss=3500W. Rotational losses= 1200W. calculate : The rotor copper loss The line current The full load motor efficiency.
Q4) A three-phase, 104 kW, 3300 V, 50 Hz, Y-connected induction motor delivers full output power...
Q4) A three-phase, 104 kW, 3300 V, 50 Hz, Y-connected induction motor delivers full output power to a load connected to its shaft. The full-load slip is 0.02 and full-load power factor is 0.85 lagging. If the stator copper loss is 2400 W, the stator core loss is 3500 W, and the friction and windage loss is 1200 W. Calculate: (i) The developed mechanical power. (ii) The air gap power. (iii) The rotor copper loss. (iv) The efficiency of the...
Problem 1: A 800 V, 4 pole, 3 phase, and 50 Hz star connected induction motor...
Problem 1: A 800 V, 4 pole, 3 phase, and 50 Hz star connected induction motor has a rotor resistance and reactance per phase equal to 0.02 ohm and 0.2 ohm respectively. Determine 1) starting torque 2) slip at which maximum torque will occur 3) speed at which maximum torque will occur 4) Maximum torque 5) full load torque if full load slip is 8%. Assume ratio of stator to rotor turns as 8.
A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full...
A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. What is the output power of this motor in kW? If friction and windage loss is 350 watts, what is the gross mechanical output at full load? What is the gross torque of this motor at full load? What is the rotor cupper loss at full load? If the efficiency of this motor is 90% at full load what is...
A 37.3 kW, 3 phase, 4 pole, 50 Hz, induction motor has a full load efficiency...
A 37.3 kW, 3 phase, 4 pole, 50 Hz, induction motor has a full load efficiency of 85%. The friction and windage losses are one third of the no load losses and the copper loss equals the iron loss at full load. Find the full load speed. Stator resistance may be neglected. [Answer: 1401.3 rpm]
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a...
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. a)-What is the synchronous speed of this motor? b)-What is the shaft speed of this motor at full load? c)-What is the frequency of rotor current at full load? d)-What is the shaft torque of this motor at full load? e)-If the efficiency of this motor is 90% at full load what is the input power f)-If the efficiency...
The following test data apply to a 7.5-hp, three-phase, 220-V, 19-A,60-Hz, four-pole induction motor with a...
The following test data apply to a 7.5-hp, three-phase, 220-V, 19-A,60-Hz, four-pole induction motor with a double-squirrel-cage rotor of design class C (high-starting-torque, low-starting current type): Test 1: No-load test at 60 Hz; Applied voltage V = 219 V line-to-line; Average phase current I1,nl = 5.70 A; Power Pnl =380 W; Test 2: Blocked-rotor test at 15 Hz; Applied voltage V = 26.5 V line-to-line; Average phase current ll,bl = 18.57 A; Power Pbl = 675 W; Test 3: Average...
There is a 4-pole three-phase induction motor of 20 kW, 60 Hz. At this time, the...
There is a 4-pole three-phase induction motor of 20 kW, 60 Hz. At this time, the slip is 0.05 when the load is applied, find secondary copper loss and secondary input.
Problem 4: A 6 pole, three phase, 50 Hz induction motor has rotor resistance of 0.075...
Problem 4: A 6 pole, three phase, 50 Hz induction motor has rotor resistance of 0.075 ohm and standstill reactance of 0.125 ohm per phase. On full load it is running at a speed of 240 r.p.m. The rotor induced e.m.f per phase at standstill is observed to be 16 V. Calculate; Starting torque, Full load torque Maximum torque Speed at max torque Problem 5: The following data refers to a 10-pole, 200 V, 50 Hz, 3 phase induction motor?
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT