Question

A four-pole asynchronous motor, indicates on its plate a power of 12.3 kW. It is star...

A four-pole asynchronous motor, indicates on its plate a power of 12.3 kW. It is star connected to a 60 Hz system and works at full load with a speed of 1746 rpm. Friction losses are 400 W, by Joule effect in stator 950 W and in rotor 350 W. Magnetic losses are 0.23 kW. Determine performance, synchronous speed, and slip.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 100 KW (OUT PUT), 3300V, 50 Hz, 3-Phase star connected induction motor has a synchronous...
A 100 KW (OUT PUT), 3300V, 50 Hz, 3-Phase star connected induction motor has a synchronous speed of 500 rpm. The full load slip is 1.8%and full load power factor 0.85. Stator copper loss=2440W. Iron loss=3500W. Rotational losses= 1200W. calculate : The rotor copper loss The line current The full load motor efficiency.
A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full...
A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. What is the output power of this motor in kW? If friction and windage loss is 350 watts, what is the gross mechanical output at full load? What is the gross torque of this motor at full load? What is the rotor cupper loss at full load? If the efficiency of this motor is 90% at full load what is...
A 37.3 kW, 3 phase, 4 pole, 50 Hz, induction motor has a full load efficiency...
A 37.3 kW, 3 phase, 4 pole, 50 Hz, induction motor has a full load efficiency of 85%. The friction and windage losses are one third of the no load losses and the copper loss equals the iron loss at full load. Find the full load speed. Stator resistance may be neglected. [Answer: 1401.3 rpm]
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a...
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. a)-What is the synchronous speed of this motor? b)-What is the shaft speed of this motor at full load? c)-What is the frequency of rotor current at full load? d)-What is the shaft torque of this motor at full load? e)-If the efficiency of this motor is 90% at full load what is the input power f)-If the efficiency...
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These...
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These are the default values of the "Asynchronous Machine" model in MATLAB Simulink. r1=0.5968 Ω; r2=0.6258 Ω; L1=0.0003495 H; L2=0.005473 H; Lm=0.0354 H; Stator line voltage = 400 V rms. The motor for rotor speeds nm= 0 to 1500 rpm. X1= 0.1097 ohm, X2= 1.719 ohm , Xm= 11.12 ohm, RTH = 0.5853 , XTH = 0.1395 and VTH = 230.82 V. Suppose the motor...
Q1. A 440 V, 60 Hz, six-pole, 3 phase induction motor is taking 50 kVA at...
Q1. A 440 V, 60 Hz, six-pole, 3 phase induction motor is taking 50 kVA at 0.8 power factor and is running at a slip of 2.5 percent. The stator copper losses are 0.5 kW and rotational losses are 2.5 kW. i) The rotor copper losses ii) The shaft hp iii) The efficiency iv) The shaft torque
A 230 volt, 60 Hz, 4 pole star connected, three phase induction motor operates at a...
A 230 volt, 60 Hz, 4 pole star connected, three phase induction motor operates at a full load speed of 1710 rpm. The power developed at this speed is 2 horse power. If the supply voltage fluctuates ±10%, determine the torque range of the motor.
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These...
The parameters of a 3-phase, 4-pole, 50 Hz, Y-connected, wound-rotor induction motor are listed below. These are the default values of the “Asynchronous Machine” model in MATLAB Simulink. r1=0.5968 ?; r2=0.6258 ?; L1=0.0003495 H; L2=0.005473 H; Lm=0.0354 H; Stator line voltage = 400 V rms. The motor for rotor speeds nm= 0 to 1500 rpm. X1= 0.1097 ohm, X2= 1.719 ohm , Xm= 11.12 ohm, RTH = 0.5853 , XTH = 0.1395 and VTH = 230.82 V. Suppose the motor...
A three-phase, 60-Hz, 4-pole, 440-V (line-line, rms) induction-motor drive has a full-load (rated) speed of 1746...
A three-phase, 60-Hz, 4-pole, 440-V (line-line, rms) induction-motor drive has a full-load (rated) speed of 1746 rpm. The rated torque is 40 Nm. Keeping the air gap flux-density peak constant at its rated value. The frequency and voltage of the motor from above are adjusted such that the fan speed is changed to 600 rpm. The motor should be operating at 3% slip and rated Bm. What is the motor efficiency?
The following test data apply to a 7.5-hp, three-phase, 220-V, 19-A,60-Hz, four-pole induction motor with a...
The following test data apply to a 7.5-hp, three-phase, 220-V, 19-A,60-Hz, four-pole induction motor with a double-squirrel-cage rotor of design class C (high-starting-torque, low-starting current type): Test 1: No-load test at 60 Hz; Applied voltage V = 219 V line-to-line; Average phase current I1,nl = 5.70 A; Power Pnl =380 W; Test 2: Blocked-rotor test at 15 Hz; Applied voltage V = 26.5 V line-to-line; Average phase current ll,bl = 18.57 A; Power Pbl = 675 W; Test 3: Average...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT