Question

A strut made of W200 x 135 x 21.4. It is a 6m long and pinned...

A strut made of W200 x 135 x 21.4. It is a 6m long and pinned at both ends. Find the Rankine Buckling load.

Homework Answers

Answer #1

I have provided conceptually correct answer.

If you have any doubts please ask me.

Please provide positive rating and thank you .

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
An axially loaded 10’ long 2”x 6” S4S Douglas Fir stud is pinned at both ends....
An axially loaded 10’ long 2”x 6” S4S Douglas Fir stud is pinned at both ends. E= 1.4 x 106 psi Allowable compressive stress parallel to the grain = 825 psi For the strong axis: What load will cause buckling? If the weak axis were braced every 30” what is the critical buckling load about the weak axis? Neglecting buckling, what is the maximum load that can be applied to the stud before it will be crushed? What would be...
A sturdy column with a hollow rectangle shape is made of steel. 150mm length and 70mm...
A sturdy column with a hollow rectangle shape is made of steel. 150mm length and 70mm width, thickness of steel=6mm. E=200Gpa -what is the max slenderness ratio if the column is pinned at both ends 3m long? -what is the critical load if the column is pinned at both ends and is 3m? -what is critical load if the column is fixed at both ends and is 7m?
Which will support more load when used as a building column: 1) A 6" x 6"...
Which will support more load when used as a building column: 1) A 6" x 6" (actual size) wood ( Douglas Fir) post 16 feet long, pinned at both ends or 2) A structural steel W10 x 39 I-beam 20 feet long, pinned at the ends
A 6-m long column is made of a steel girder W200x52 (see the section properties in...
A 6-m long column is made of a steel girder W200x52 (see the section properties in the last page). It is loaded concentrically through the centroid of the section. Given that the steel has the elastic modulus Est = 210 GPa and the yield stress Y = 340 MPa. Determine the critical load (Euler Buckling Load, Pcr) where the support at the column ends are fixed-free support
Determine if the following column is long or short, and then determine the critical load on...
Determine if the following column is long or short, and then determine the critical load on a steel column having a rectangular cross section, 12mm by 18mm and a length of 250 mm. It is fixed on both ends and made from a steel that has the following properties: E= 209 Gpa and sy = 290 Mpa. Slenderness ratio = ___________ Cc = _______ Long or short column = ___________ Critical load = ____________________ Newtons
For a 8m long column whose cross sectional dimensions are 0.1m x 0.4m, determine the allowable...
For a 8m long column whose cross sectional dimensions are 0.1m x 0.4m, determine the allowable load using a safety factor of 2.5. The column is welded at both ends. Its yield stress is 250 MPa and its modulus of elasticity is 210 GPa. using Euler Formula or J. B. Johnson Formula.
light of wavelength 580 nm is incident on a slit of width 5.47 x 10^-6m. An...
light of wavelength 580 nm is incident on a slit of width 5.47 x 10^-6m. An observing screen is placed 2.00 m from the slit. A) Find he position of the first order dark fringe from the center of the screen (in meters) B) At most, how many dark fringes can be formed on either side of the central bright fringe (assuming that the observing screen is infinitely long)?
determine the adequacy of a 12-ft long W12x40 column in a braced frame to resist a...
determine the adequacy of a 12-ft long W12x40 column in a braced frame to resist a factored axial load of 120 kips and factored moments of 125ft-kips and 55ft-kops about the x and y axis, redpectively. The column is assumed to be painted at both ends. Use ASTM A992 steel.
A long, narrow solenoid is made from copper wire, with resistivity 1.70 x 10-8 Ω The...
A long, narrow solenoid is made from copper wire, with resistivity 1.70 x 10-8 Ω The wire has a diameter of 0.12 mm and the effective diameter of the solenoid is 1.85 cm. The solenoid is made of 3000 closely packed turns. If a voltage supply is initially 12.00 volts and the voltage is increased steadily at the rate of 0.25 volts/sec, at what rate will the magnetic field increase inside the solenoid.
A long, narrow solenoid is made from copper wire, with resistivity 1.70 x 10-8 Ω The...
A long, narrow solenoid is made from copper wire, with resistivity 1.70 x 10-8 Ω The wire has a diameter of 0.12 mm and the effective diameter of the solenoid is 1.85 cm. The solenoid is made of 3000 closely packed turns. If a voltage supply is initially 12.00 volts and the voltage is increased steadily at the rate of 0.25 volts/sec, at what rate will the magnetic field increase inside the solenoid.
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question