Which of the following is true regarding fabric filter
control?
____ (a) The maximum pressure drop in a shaker-type baghouse occurs
just prior to the time when a compartment is taken off-line for
cleaning
____ (b) The cleaning process returns bags to the original clean
state (when brand new)
____ (c) Optimal air-to-cloth ratios depend only on the type of
particles to be collected
____ (d) Highly flammable dusts may preclude the use of a
baghouse
____ (e) A clean-side fan (on the outlet side) is required for all
types of baghouses
(d) Highly flammable dusts may preclude the use of a baghouse
Explanation
Minimum operating temperature is especially important where acid gases are expected to be present in the gas stream. Lower temperatures mean acid gases have the potential to condense and corrode the fabric filter casing and other metal parts. Condensation can also cause bag blinding, which blocks air flow through the bag. Fabric filters are also susceptible to damage caused by high temperatures.