Question

A sturdy column with a hollow rectangle shape is made of steel. 150mm length and 70mm...

A sturdy column with a hollow rectangle shape is made of steel. 150mm length and 70mm width, thickness of steel=6mm.
E=200Gpa
-what is the max slenderness ratio if the column is pinned at both ends 3m long?
-what is the critical load if the column is pinned at both ends and is 3m?
-what is critical load if the column is fixed at both ends and is 7m?

Homework Answers

Answer #1

a). Maximum slenderness ratio if the column is pinned at both ends 3m long = 104.84.

b). Critical load if column is pinned at both ends 3 m long = 4.482 × 10^17 N.

c). Critical load if the column is fixed at both ends, 7m long = 3.293 × 10^17 N.

(Please give a thumbs up ).

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A hollow, round column has length of 1.5m, material aluminum, OD = 20mm, and ID =...
A hollow, round column has length of 1.5m, material aluminum, OD = 20mm, and ID = 14mm. Use Sy = 150 MPa for aluminum. Determine if it is a Johnson or Euler column and find the critical load for the following end conditions: A) Pinned-pinned B) Fixed-pinned C) Fixed-fixed D) Fixed-free
Select a light W shape for a column subjected to an axial compressive load of 1623kN....
Select a light W shape for a column subjected to an axial compressive load of 1623kN. The unbraced length of column is 5m and the ends are pinned. Use A36 grade steel.
A steel column has a length of 40 ft and is fixed at both ends. If...
A steel column has a length of 40 ft and is fixed at both ends. If the cross sectional area has the dimensions of a wide flange W10x39, determine the critical load at: 1) fixed to fixed 2) fixed to pin 3) pin to pin Please put answers in lb. Show all work please
A 6-m long column is made of a steel girder W200x52 (see the section properties in...
A 6-m long column is made of a steel girder W200x52 (see the section properties in the last page). It is loaded concentrically through the centroid of the section. Given that the steel has the elastic modulus Est = 210 GPa and the yield stress Y = 340 MPa. Determine the critical load (Euler Buckling Load, Pcr) where the support at the column ends are fixed-free support
A hollow circular steel column 2m long and outer diameter 200 mm carries an axial load...
A hollow circular steel column 2m long and outer diameter 200 mm carries an axial load of 325 kN. If the compressive stress is 150 MPa, lateral strain for external diameter is is 0.000325 and Poisson’s ratio is 0.3, find the minimum wall thickness required for the column. Also calculate the shear modulus for the material of the column. Take E = 210 GPa.   
2) A bimetallic strip is made of copper and steel fused together. The length of each...
2) A bimetallic strip is made of copper and steel fused together. The length of each piece is 23 cm at 25 Celsius and the thickness of the copper is .6mm and the steel is .8mm. a) If the temperature of the strip goes from 25 to 35 Celsius, what is the subtended angle of the arc that the strip makes? [Assume that the thickness does not change appreciably compared to the length of the pieces] b) To what temperature...
During construction, field tests were conducted to assess the suitability of the column to withstand a...
During construction, field tests were conducted to assess the suitability of the column to withstand a safe buckling load of 2.5 kN assuming a factor of safety 4 using two different hollow columns made up of steel and concrete. Both columns have same cross section but varying length and different support conditions. Steel column of length 3 m having external diameter 40 mm was tested with one end fixed and the other end hinged, when subjected to a compressive stress...
1: During construction, field tests were conducted to assess the suitability of the column to withstand...
1: During construction, field tests were conducted to assess the suitability of the column to withstand a safe buckling load of 2.5 kN assuming a factor of safety 4 using two different hollow columns made up of steel and concrete. Both columns have same cross section but varying length and different support conditions. Steel column of length 3 m having external diameter 40 mm was tested with one end fixed and the other end hinged, when subjected to a compressive...
A column is made of concrete and reinforced with a W-section steel with an area of...
A column is made of concrete and reinforced with a W-section steel with an area of 2000 mm2. The dimension of the column is 300mm x 350mm. The column is subjected to an axial load of 100 kN. What will be the deformed length of the column? Use Es = 200 GPa and Ec = 25 GPa.
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT