Question

1. The diameter of the discharge pipe of a centrifugal pump is 15 cm and the...

1. The diameter of the discharge pipe of a centrifugal pump is 15 cm and the that of

the intake pipe is 20 cm The pressure gage connected to the discharge pipe at the

pump outlet reads 207 kPa, and the vacuum gage connected to the intake pipe at

the pump inlet reads 25 cm of mercury. If the pump discharge is 84.7 L/s and the

power needed to run the pump is 35 HP, what is the pump efficiency?


Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A centrifugal pump with a 10 cm suction pipe and a 7.5 cm diameter discharge pipe...
A centrifugal pump with a 10 cm suction pipe and a 7.5 cm diameter discharge pipe has a measured capacity of 0.019 m3/s (water), a suction side vacuum of 20 cm mercury (relative density = 13.6) and a discharge pressure of 240345 N/m2 (gage).  The suction and discharge pipes are at the same elevation.  Assuming that the head loss due to friction is negligible, what is the pump power required
A discharge of 2.8m^3/s flows through a hydraulic turbine. On the 1 m inlet pipe at...
A discharge of 2.8m^3/s flows through a hydraulic turbine. On the 1 m inlet pipe at elevation 43.5 m, a pressure gage reads 345 kPa. On the 1.5 m discharge pipe at elevation 39, a vacuum gage reads 150 mm of mercury. If the total head lost through pipes and turbines between elevation 43.5 and 39 is 9 m, what power may be expected from the machine?
A centrifugal pump has an impeller of outer diameter, 20 cm and outer width,4 cm. The...
A centrifugal pump has an impeller of outer diameter, 20 cm and outer width,4 cm. The pump delivers a flow of 30 L/s against a head of 10.5 m at an operating speed of 550 rpm. If the hydraulic efficiency of the pump is 85% and the overall efficiency is 80%, determine the impeller outlet vane angle and the power required to run the pump.
A discharge of 2.8 m3 /s flows through a hydraulic turbine. On the 1 m inlet...
A discharge of 2.8 m3 /s flows through a hydraulic turbine. On the 1 m inlet pipe at elevation 43.5 m, a pressure gage reads 345 kPa. On the 1.5 m discharge pipe at elevation 39, a vacuum gage reads 150 mm of mercury. If the total head lost through pipes and turbines between elevation 43.5 and 39 is 9 m, what power may be expected from the machine?
A 50 mm diameter tube has a length of 35 m and inclined upward with 15...
A 50 mm diameter tube has a length of 35 m and inclined upward with 15 degree with the horizontal (Figure). The discharge is 5.5 L/s and the outlet pressure required to be 75 kPa gage pressure. Estimate the inlet gage pressure in kPa of this tube if the coefficient of friction (f) in the losses equation   is 0.03.
The rotation speed of a centrifugal water pump is 1500 rpm, its flow rate is 15...
The rotation speed of a centrifugal water pump is 1500 rpm, its flow rate is 15 L / s, the rotor diameter is 0.2 m at the outlet, the rotor width at the outlet is 0.01 m and the mechanical efficiency is 0.92. For the fluid entering the rotor in the axial direction, the wing angle is given as 30o at the outlet. What power should be given to the shaft of this pump? (ρwater = 1000 kg / m3)
Q1/ Centrifugal pump runs at (1200 r.p.m) and the velocity of flow through the impeller is...
Q1/ Centrifugal pump runs at (1200 r.p.m) and the velocity of flow through the impeller is constant (4 m/s). It works with total head of (32m). The vanes are set back at an angle of (30°) at outlet .The outer diameter of the impeller is (600 mm) while the width of outlet is (50mm). Determine 1) work done per second by impeller 2) Vane angle at inlet 3)discharge 4)efficiency
An electric pump consumes 15 kW electricity, and is used to pump water at a volumetric...
An electric pump consumes 15 kW electricity, and is used to pump water at a volumetric rate of 50 L/s. The absolute pressures at the inlet and outlet of the pump 100 kPa and 300 kPa. Assuming that there is negligible difference in kinetic energy between the inlet and the outlet (how is that possible?) and that there is negligible difference in height between the inlet and the outlet, calculate: (A) the mechanical efficiency of the pump, and (B) the...
1. Pressures on the suction side and the discharge side of a pump are read by...
1. Pressures on the suction side and the discharge side of a pump are read by the pressure gauges as (i) vacuum of 250 mm of mercury (specific gravity 13.6) and (ii) 137 kN.m2 respectively. The gauge on the suction side is placed 600 mm below the centreline of the pump whereas the gauge on the discharge side is placed 170 mm above the centreline. If the diameters of the pipes on suction and discharge are 150 mm and 100...
A Centrifugal pump is used to transfer a volatile organic solvent (SG = .9 , mu...
A Centrifugal pump is used to transfer a volatile organic solvent (SG = .9 , mu = .003 Pa*s) from a remote storage tank to an exraction column. The pump requires NPSH of 5 m. The solvent level in the storage tank is maintained at 2 m above the pump inlet. The solvent flows at 45 kg/s through 16 cm smooth pipe. The solvent has a vapor pressure of 26.7 kPa and the pressure in the storage tank is atmospheric....
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT