  1. A trickling filter plant consists of a primary sedimentation tank, a trickling filter 21 m in diameter and 2 m depth, and a secondary sedimentation tank. The primary effluent BOD is 100 mg/L, the plant final effluent is 25 mg/L and the recirculation flow is 0.5 of the wastewater flow entering the plant. The temperature of the water is 15oC. The constants for the random plastic media are n = 0.5 and   k20 = 0.055 min-1. Calculate the hydraulic loading.

Homework Answers

Answer #1

Volume = =692,721.18 litres

Sewage flow = 692,721.18 litres/day

Total B.O.D.5 present in sewage = 100mg/l x 692,721.18 litres/day x 10-6=69.27 kg/day

Volume of Filter media required=

Orginal Loading= .099 kg/m3day

Surface area required for the filter=

=

Hydraulic Loading= 2000l/m2day

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A municipal wastewater having a BOD5 of 225 mg/L is to be treated by a two-stage...
A municipal wastewater having a BOD5 of 225 mg/L is to be treated by a two-stage trickling filter. The desired effluent quality is 30 mg/L of BOD5. If both of the filter depths are to be 1.83 m and the recirculation ratio is 2:1, find the required filter diameters if both the two trickling filers have same removal efficiencies. Use NRC equation and the following design assumptions. Design assumptions: o Influent flow = 10,000 m3 /d o Recirculation ratio =...
.Calculate the effluent BOD of 2 Stage trickling filter with the following data: Flow rate =...
.Calculate the effluent BOD of 2 Stage trickling filter with the following data: Flow rate = 3.15 m3/min, BOD5 = 290 mg/lt V1 = V2 = 830 m3, Filter depth = 3 m Recirculation of filter1 = 125% of Q Recirculation of filter2 = 100% of Q
the design flow for a plant, using 4 tricking filters with a plastic media, is 0.5...
the design flow for a plant, using 4 tricking filters with a plastic media, is 0.5 mgd. the filters will be in parallel, the influent bod5 to filters will be 200 mg/l, the required effluent bod 5 will e 25 mg/l, the trickling filter design depth is 25 ft. lab testing conducted at 25c and 40 ft depth found the biodegradability constant to be 0.865/ft 0.5 d ^0.5. find the diameter required for each trickling filters.
A wastewater treatment plant that treats wastewater to secondary treatment standards uses a primary sedimentation process...
A wastewater treatment plant that treats wastewater to secondary treatment standards uses a primary sedimentation process followed by an activated sludge process composed of aeration tanks and a secondary clarifiers. This problem focuses on the activated sludge process. The activated sludge process receives a flow of 15 million gallons per day (MGD). The primary sedimentation process effluent has a BOD5 concentration of 180 mgBOD5/L (this concentration is often referred as S). Before flowing into the activated sludge process, the primary...
Determine the area required for a FWS constructed wetland used to treat primary treated wastewater with...
Determine the area required for a FWS constructed wetland used to treat primary treated wastewater with an influent BOD of 120 mg/L. To be assured of odorless operation, the maximum organic loading rate is to be equal to or less that 100 lb BOD/ac.d. Assume the overall first-order BOD removal rate constant is 1.0 d-1 at 20°C. The average wastewater temperature during the coldest month is about 10°C. The average water depth is to be 1.25 ft. Because of evaporation,...
A wastewater plant with the activated sludge process received 5 × 106 L/day of wastewater with...
A wastewater plant with the activated sludge process received 5 × 106 L/day of wastewater with a BOD5 of 500 mg/L. The primary clarifier removes 30% of the BOD and primary clarify effluent has no biomass (Xi=0 mg/L). Recycle (Qr) and waste sludge (Qw) flows are 25% and 2% of Qin, respectively. Effluent BOD5 from secondary clarifier and waste sludge is 20 mg/L. Microorganism concentration in the waste sludge (Xw) is 6,000 mg/L. Soluble BOD5 is biologically converted into CO2...
The town of Camp Verde has been directed to upgrade its primary Waste Water Treatment Plant...
The town of Camp Verde has been directed to upgrade its primary Waste Water Treatment Plant (WWTP) to a secondary plant that can meet an effluent standard of 25 mg/L BOD5 and 30 mg/L suspended solids. They have selected a completely mixed activated sludge system for the upgrade. The existing primary treatment plant has a flow rate of 0.029 m3/s. The effluent from the primary tank has a BOD5 of 240 mg/L. Using the following assumptions, estimate the required volume...
Problem #3: Biochemical Oxygen Demand (BOD) and Stream Quality A wastewater treatment plant designed for a...
Problem #3: Biochemical Oxygen Demand (BOD) and Stream Quality A wastewater treatment plant designed for a community of 45,000 people has a flow of 100 gal/person/day and a BOD5 loading of 0.2 lb/person/day. The upstream characteristics of the receiving waters are: stream flow rate = 20 cfs and BOD5 = 2 mg/L The water quality standards require the in-stream BOD5 to be less than 7 mg/L in this stretch of the river. The minimum BOD removal efficiency that the treatment...
A completely mixed activated-sludge process is being designed for a wastewater flow of (2.64 mgd) using...
A completely mixed activated-sludge process is being designed for a wastewater flow of (2.64 mgd) using the kinetics equations. The influent BOD of 120 mg/Lis essentially all soluble and the design effluent soluble BOD is 7 mg/L, which is based on a total effluent BOD of 20 mg/L. For sizing the aeration tank, the mean cell residence time is selected to be10 days and the MLVSS 2000 mg/L. The kinetic constants from a bench-scale treatability study are as follows: Y...
A conventional activated sludge plant treating a domestic flow of 150 ML/d is operated at a...
A conventional activated sludge plant treating a domestic flow of 150 ML/d is operated at a SRT of 10 d with a MLVSS of 3500 ppm. The activated sludge plant is required to reduce the influent BOD from 200 ppm to less than 10 ppm prior to discharge. The discharge from the aeration basin is clarified, such that the clarifier overflow contains no particulate material and the MLVSS of the recycle stream is 8000 ppm. You are required to determine...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT