Don’t worry yourself...just read and understand your book.... Q. The cement content in the mixture with 150 kg/m3 of water and water-cement ratio of 0.45 is ___________.
If moisture content is 5% and aggregate density is 500 kg/m3. The final weight of the aggregate is _______
If the moisture content of aggregate is 1% and absorption is 4%, the water contributed to the mixture is _________
...
If the fine aggregate is 300 kg/m3 and total aggregate is 1000 kg/m3, what is the weight of coarse aggregates_________

Homework Answers

Answer #1

1. Cement content = (Water content) / (w/c)

= 150/0.45

Cement content = 333.33 kg

2. Aggregate density = 500 kg/m3

Moisture content = 5%

Final weight of aggregate = Aggregate density * ( 1 + moisture content)

Final weight of aggregate = 500 * (1 + 0.05)

Final weight of aggregate = 525 kg

3. Moisture content of aggregate = 1%

Absorbed water = 4%

Only moisture content contributes water to the mixture. Absorbed water is used only to adjust the quantity of aggregates.

Therefore,

Moisture contributed to the mixture = 1%

4. Fine aggregate = 300 kg/m3

Total aggregates = 1000 kg/m3

Total aggregates = Coarse aggregates + Fine aggregates

Therefore,

Weight of coarse aggregates = Total aggrgates - Fine aggregates

Weight of coarse aggregates = 1000 - 300

Weight of coarse aggregates = 700 kg/m3

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Calculate the field weights of the ingredients for 0.039 m3 of concrete by using ACI Method...
Calculate the field weights of the ingredients for 0.039 m3 of concrete by using ACI Method of Mix Design. Job specifications dictate the followings:   Cement content: 300 kg/m3 w/c: 0.57 (by weight, from the strength point of view) w/c: 0.53 (by weight, from durability point of view) Fine Aggregate (SSD)/Coarse Aggregate (SSD)=0.45 (by weight) Air Content: 1,30 %   For Fine Aggregate (Crushed): SSD Bulk Specific Gravity: 2.47, Total Moisture: 5,0 % and Absorption Aggregate: 2,7 %.   For Coarse Aggregate (Crushed):...
Concrete is required for an interior concrete column in a commercial building in Corvallis, Oregon. A...
Concrete is required for an interior concrete column in a commercial building in Corvallis, Oregon. A specified compressive strength, f’c , of 4000 psi is required at 28 days using an ASTM C 150 Type I. The design calls for a minimum of 3 in. of concrete cover over the reinforcing steel. The minimum distance between reinforcing bars is 2.5 in. A slump of 4 inches should be the target. No statistical data on previous mixes are available. Follow mixture...
Q2)What would be the maximum aggregate size used for the given mixture properties by using ACI...
Q2)What would be the maximum aggregate size used for the given mixture properties by using ACI Method of Mix Design. 28-day specified concrete strength is 3bMpa, standard deviation is choosen as 3.aMpa and it is required that no more than 1 test result in 200 will fall below the specified strength. Project Title:Detoration of wood column of a commercial building Project summary:Wood deterioration at the lower level of a heavy timber column, which supports five floor levels, was remedied by...