A soil deposit has a unit weight of 120 pcf above the groundwater and 128pcf below...

A soil deposit has a unit weight of 120 pcf above the groundwater and 128pcf below the groundwater. It has an undrained shear strength (Su) of 500psf, effective cohession (c') of 200psf, and effective friction angle (φ') of 31 degrees and extends to a great depth. the groundwater table is at 15 ft below ground surface

A) What is the short term (undrained) shear strength of the soil at a depth of 30ft below ground surface?

Homework Answers

Answer #1

Given unit weights are mentioned in the figure , and plastic equilibrium condition means every soil particle is at the verge of failure, this condition is used inorder to find minor principal stress.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A soil deposit has a unit weight of 120 pcf above the groundwater and 128pcf below...
A soil deposit has a unit weight of 120 pcf above the groundwater and 128pcf below the groundwater. It has an undrained shear strength (Su) of 500psf, effective cohession (c') of 200psf, and effective friction angle (φ') of 31 degrees and extends to a great depth. the groundwater table is at 15 ft below ground surface A) What is the short term (undrained) shear strength of the soil at a depth of 30ft below ground surface?
The site you are investigating in Beaufort, SC, has soft clay deposit overlying a sand deposit....
The site you are investigating in Beaufort, SC, has soft clay deposit overlying a sand deposit. The soft clay deposit ranges from the existing ground surface to a depth of 5 ft, while the sand deposit extends from a depth of 5 ft to a depth of 20 ft. Underlying the sand deposit is the Cooper Marl Formation. The groundwater table is located 2 ft below the ground surface. You have determined that the proposed structure will need to be...
A 10 ft wall retains soil with a horizontal surface that has 115 pcf unit weight,...
A 10 ft wall retains soil with a horizontal surface that has 115 pcf unit weight, a friction angle of 26 degrees, and an effective cohesion c’= 50 psf. The water table is at 5ft depth. Assuming Rankine active lateral earth pressures and hydrostatic conditions, what is the total horizontal thrust that the wall feels
Calculate the total overburden stress, pore water pressure, and effective overburden stress at a depth of...
Calculate the total overburden stress, pore water pressure, and effective overburden stress at a depth of 12 feet for the given soil profile. A 2 ft sand layer with total unit weight of 107 pcf that is overlaying a 14 ft deep saturated clay layer with a total unit weight of 118 pcf, sitting on the bedrock. The groundwater table is 2 ft below the ground surface.
Determine the allowable design load for a column resting on a rectangular footing 2 m by...
Determine the allowable design load for a column resting on a rectangular footing 2 m by 9 m, buried to a depth of 2 m in clay soil with a unit weight of 18.5 kN/m3, internal friction of 39 degrees, a drained cohesion of 36 kPa and undrained shear strength of 119 kPa. Assume the short-term condition governs, water table is at the ground surface and use a factor of safety of 3. Provide your answer in kN as a...
Part A A square foundation has a width of 2.0 m. The soil has a friction...
Part A A square foundation has a width of 2.0 m. The soil has a friction angle of φ' = 27 and c' = 15 kN/m2. The unit weight of the soil γ = 18 kN/m3. Determine the allowable gross load (kN) on the foundation with a factor of safety of of 3. Assume that the depth of the foundation is 2.0 m and that general shear failure occurs in the soil. Give only the numeric answer (no unit). Part...
Determine the total force per unit length acting on a 4.8 m high retaining wall. The...
Determine the total force per unit length acting on a 4.8 m high retaining wall. The soil that is backfilled level behind the wall is a granular soil with a total unit weight of 18.2 kN/m3 and a saturated unit weight of 19.6 kN/m3. Use an at-rest earth pressure coefficient for the soil which has an internal angle of friction of 26 degrees. The water table is expected to rest at a depth of 1.5 below the ground surface. Report...
QUESTION 2 A square footing has to be designed using Terzaghi's bearing capacity equation on a...
QUESTION 2 A square footing has to be designed using Terzaghi's bearing capacity equation on a soil with these given parameters: unit weight =115 lb/ft? effective angle of internal friction = 30°, effective cohesion = 500 lb/ft, factor of safety = 3. The bottom of the footing is located at 5 ft below the ground surface. The ground water table is far below the bottom of the footing and has no impact on soil bearing capacity. What is the minimum...
A wall is supported on a 1.0 m wide strip footing located 1.5 m below the...
A wall is supported on a 1.0 m wide strip footing located 1.5 m below the ground surface. The surrounding soil has a dry unit weight of 17.5 kN/m3, a saturated unit weight of 19.0 kN/m3, cohesion of 8 kPa and angle of internal friction of 26°. Groundwater was located 2m below ground surface. Using a factor of safety of 3, determine the allowable bearing capacity if a) the footing is considered infinitely long, and b) the footing is 8...
a five meter retaining wall has to retain backfill of sandy soil having a unit weight...
a five meter retaining wall has to retain backfill of sandy soil having a unit weight 18.2 kn/m3 and angle of internal friction 32 degree,the surface of the backfill in inclined at an angle of 10 degree to the horizontal determine:the magnitude and point of application of the active thrust on the wall,draw a diagram of given situation ,and determine total active earth pressure acting with vertical or with horizontal.