Question

reinforced concrete beam if increasing the area of steel would increase the beam strength why we...

reinforced concrete beam if increasing the area of steel would increase the beam strength why we don't do that? Explain and show graph drawing

Homework Answers

Answer #1

why over reinforcement in concrete members is not preferable.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Since steel in our reinforced concrete bears most of the tensile loads, why is it still...
Since steel in our reinforced concrete bears most of the tensile loads, why is it still important to know the tensile strength of concrete? List one example or type of structure where tensile strength might play a role in the performance or durability of a concrete structure.
A reinforced concrete beam is constructed with Grade 30 concrete which has a cross section of...
A reinforced concrete beam is constructed with Grade 30 concrete which has a cross section of 450 mm x 660 mm (b = 450 mm and D = 660 mm). The length of the beam is 5 m. The elastic modulus of the concrete is 32.8 GPa. A uniformly distributed live load of 23 kN/m is acting on the beam. Determine (a) the design bending moment on this beam for strength limit state, (b) modular ratio assuming Es = 200...
Determine the largest allowable bending moment for a rectangular reinforced concrete beam having the width b...
Determine the largest allowable bending moment for a rectangular reinforced concrete beam having the width b = 200 mm, total height h = 375 mm and the distance from the bottom surface of the beam to the centre line of steel bars = 75 mm. Use the total area of steel As = 1360 mm2, modulus of elasticity of concrete = 30 GPa, modulus of elasticity of steel = 210 GPa, allowable compressive stress for concrete = 15 MPa and...
. A rectangular beam of size 300 * 600 mm is reinforced with steel bars of...
. A rectangular beam of size 300 * 600 mm is reinforced with steel bars of area 1530 mm^2. Concrete of Grade C-25 and steel of Grade 420 is to be used. Depth of neutral axis (y-dash) is found to be 312 mm. Find the stress at the bottom of the section, if applied bending moment is 45 KN-m.
A column is made of concrete and reinforced with a W-section steel with an area of...
A column is made of concrete and reinforced with a W-section steel with an area of 2000 mm2. The dimension of the column is 300mm x 350mm. The column is subjected to an axial load of 100 kN. What will be the deformed length of the column? Use Es = 200 GPa and Ec = 25 GPa.
A simply supported reinforced-concrete beam has to resist a maximum factored moment of M* = 210...
A simply supported reinforced-concrete beam has to resist a maximum factored moment of M* = 210 KN-m. Given that f’c = 32 MPa, fy = 500 MPa and that the maximum possible width for the beam is 240 mm: a. Establish an appropriate structural depth ‘d’ for the beam b. Determine the total depth ‘D’ of the beam for a FRL of 90 minutes c. Find the area of steel Ast required to resist the moment and select the rebars....
What is development length? Why is the development length important in reinforced concrete design? How is...
What is development length? Why is the development length important in reinforced concrete design? How is the development length typically expressed? What is the top bar effect and why does it increase the development length for concrete? Why does the epoxy coating impact the development length of concrete How does lightweight concrete impact the development length? Do you think it is safe to reduce the development length if you provide more steel than you are required in your design? If...
Find the area of steel reinforcement required for concrete T-beam for the following data: ƒy is...
Find the area of steel reinforcement required for concrete T-beam for the following data: ƒy is 40 ksi, ƒ’c is 3 ksi. d = 28 inches t = 6 inches bw = 16 inches bƒ = 6 inches Mu = 345 kip - ft
discuss why their is an increase in use of steel as opposed concrete in constructions
discuss why their is an increase in use of steel as opposed concrete in constructions
When altering the area and young's modulus units of a concrete beam. Why will this not...
When altering the area and young's modulus units of a concrete beam. Why will this not change the bending moment and shear force diagram, from the original result?